基于CT尿路造影碘美普尔清除率测量活体肾供体候选者肾小球滤过率
本横断面回顾性研究纳入75例活体肾供体候选者,基于CT尿路造影动脉期与排泄期碘美普尔排泄率计算CT测量GFR,并与碘海醇清除率参考标准比较。CT测量GFR平均偏倚1.1 mL/min/1.73 m2(95%CI:-1.9,4.1),精确度16.2 mL/min/1.73 m2,10%、20%、30%准确率分别为61.3%、88.0%、100%。
要点
- CT测量GFR与碘海醇清除率平均偏倚1.1 mL/min/1.73 m2(95%CI:-1.9,4.1),无系统偏倚。
- CT测量GFR落在参考标准10%、20%、30%以内的比例分别为61.3%、88.0%、100%。
- 间隔2个月CT测量GFR一致性相关系数0.99(95%CI:0.98,0.99)。
核心结论
- 在活体肾供体中,基于CT尿路造影碘美普尔清除率测量的GFR与基于碘海醇清除率测量的GFR显示出良好一致性。
研究设计与样本
- 横断面回顾性研究,纳入2016年7月至2022年10月间同时接受碘海醇清除率和CT尿路造影检查的活体肾供体候选者75例(平均年龄51岁±13[SD],女性45例),以碘海醇清除率为参考标准。
关键影像表现/征象
- CT测量GFR按动脉期至排泄期泌尿系统碘美普尔排泄率(Hounsfield单位乘以毫升每分钟)除以中点主动脉血清碘美普尔浓度替代值(Hounsfield单位)计算。
诊断标准与关键数值
- CT测量GFR平均偏倚为1.1 mL/min/1.73 m2(95%CI:-1.9,4.1),精确度为16.2 mL/min/1.73 m2(四分位距-6.6至9.6)。
- CT测量GFR落在碘海醇清除率10%以内的准确率为61.3%(95%CI:50.3,72.4),20%以内为88.0%(95%CI:80.7,95.4),30%以内为100%。
- 随机选取30例评估观察者内一致性,Lin一致性相关系数为0.99(95%CI:0.98,0.99)。
临床应用与阅片要点
- 在活体肾供体候选者CT尿路造影中,可基于动脉期与排泄期图像计算碘美普尔清除率以测量GFR。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Estimating glomerular filtration rate (GFR) from serum creatinine can be inaccurate, and current procedures for measuring GFR are time-consuming and cumbersome. Purpose To develop a method for measuring GFR based on iomeprol clearance assessed at CT urography in kidney donor candidates and compare this with iohexol clearance (reference standard for measuring GFR). Materials and Methods This cross-sectional retrospective study included data from kidney donor candidates who underwent both iohexol clearance and CT urography between July 2016 and October 2022. CT-measured GFR was calculated as the iomeprol excretion rate in the urinary system between arterial and excretory phases (Hounsfield units times milliliters per minute) divided by a surrogate for serum iomeprol concentration in the aorta at the midpoint (in Hounsfield units). Performance of CT-measured GFR was assessed with use of mean bias (mean difference between CT-measured GFR and iohexol clearance), precision (the distance between quartile 1 and quartile 3 of the bias [quartile 3 minus quartile 1], with a small value indicating high precision), and accuracy (percentage of CT-measured GFR values falling within 10%, 20%, and 30% of iohexol clearance values). Intraobserver agreement was assessed for 30 randomly selected individuals with the Lin concordance correlation coefficient. Results A total of 75 kidney donor candidates were included (mean age, 51 years ± 13 [SD]; 45 female). The CT-measured GFR was unbiased (1.1 mL/min/1.73 m2 [95% CI: -1.9, 4.1]) and highly precise (16.2 mL/min/1.73 m2 [quartiles 1 to 3, -6.6 to 9.6]). The accuracy of CT-measured GFR within 10%, 20%, and 30% was 61.3% (95% CI: 50.3, 72.4), 88.0% (95% CI: 80.7, 95.4), and 100%, respectively. Concordance between CT-based GFR measurements taken 2 months apart was almost perfect (correlation coefficient, 0.99 [95% CI: 0.98, 0.99]). Conclusion In living kidney donors, GFR measured based on iomeprol clearance assessed at CT urography showed good agreement with GFR measured based on iohexol clearance. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Davenport in this issue.
引用
- Stehlé T, Wei F, Brabant S, et al. Glomerular Filtration Rate Measured Based on Iomeprol Clearance Assessed at CT Urography in Living Kidney Donor Candidates. Radiology. 2023. PMID: 38085083. doi:10.1148/radiol.230567
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。