非对比增强磁共振血管成像评估移植肾动脉狭窄:与数字减影血管造影的比较
本研究在60例经DSA确诊的移植肾动脉狭窄患者中,采用平衡触发非对比增强磁共振血管成像(B-TRANCE)评估狭窄程度并与DSA比较。NCE-MRA图像质量优良,观察者间一致性高(Kappa=0.836),对≥50%显著狭窄的敏感度100%、特异度90.91%、准确率96.55%。
要点
- B-TRANCE NCE-MRA图像质量优秀占81.67%、良好占8.33%、中等占6.67%、无法诊断占3.33%。
- NCE-MRA与DSA评估移植肾动脉狭窄程度无显著差异(P=0.317)。
- NCE-MRA检测≥50%显著狭窄的敏感度100%、特异度90.91%、准确率96.55%。
核心结论
- 基于B-TRANCE技术的NCE-MRA在评估移植肾动脉狭窄方面与DSA表现出良好一致性,对狭窄严重程度的评估具有高敏感度、特异度和准确率。
研究设计与样本
- 在60例经DSA确诊移植肾动脉狭窄的患者中,采用B-TRANCE磁共振血管成像评估狭窄程度并与DSA比较,图像质量由两名放射科医师独立评估。
关键影像表现/征象
- 基于B-TRANCE技术的移植肾动脉NCE-MRA图像质量充分:优秀81.67%、良好8.33%、中等6.67%、无法诊断3.33%。
- NCE-MRA与DSA评估移植肾动脉狭窄程度无显著差异(P=0.317)。
诊断标准与关键数值
- NCE-MRA检测≥50%显著移植肾动脉狭窄的敏感度100%、特异度90.91%、准确率96.55%、阳性预测值94.74%、阴性预测值100%。
- NCE-MRA图像质量评估的观察者间一致性Kappa=0.836。
- DSA识别重度、中度、轻度狭窄的动脉分别为6条、32条、22条。
临床应用与阅片要点
- NCE-MRA基于B-TRANCE技术可用于评估移植肾动脉狭窄程度,与DSA结果一致性良好。
- 阅片时注意NCE-MRA图像质量存在无法诊断的情况(3.33%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Early diagnosis of transplant renal artery stenosis (TRAS) is crucial for salvaging kidney function and improving patient prognosis. The purpose of this study was to evaluate image quality of non-contrast-enhanced MR angiography (NCE-MRA) and the value of NCE-MRA in evaluating TRAS compared to DSA.
MATERIALS AND METHODS: In 60 patients with TRAS confirmed by DSA, the degree of TRAS was assessed using balanced triggered angiography non-contrast-enhanced (B-TRANCE) MR angiography and was compared to that of DSA. Image quality for NCE-MRA was assessed independently by two radiologists. The Wilcoxon signed-rank test was used to compare NCE-MRA with DSA in assessing TRAS degree. Specificity, sensitivity, accuracy, positive-predictive value (PPV), and negative-predictive value (NPV) of NCE-MRA for the detection of marked (≥50%) TRAS were calculated.
RESULTS: The image quality of NCE-MRA based on the B-TRANCE technology of transplanted renal arteries was sufficient (excellent in 81.67%, good in 8.33%, moderate in 6.67%, and non-diagnostic in 3.33%) and had a high inter-observer reproducibility (Kappa=0.836). DSA helped identify severe, moderate, and mild stenosis in 6, 32, and 22 arteries, respectively. No significant difference in the extent of TRAS between NCE-MRA and DSA were observed (P = 0.317). The specificity, sensitivity, accuracy, PPV, and NPV of NCE-MRA in detecting marked (≥50%) TRAS were 90.91%, 100%, 96.55%, 94.74%, and 100%, respectively.
CONCLUSION: NCE-MRA based on B-TRANCE technology has shown promising consistency with DSA in evaluating TRAS and yielding high sensitivity, specificity, and accuracy in assessing the severity of TRAS.
引用
- Pan L, Shen L, Fan M, et al. Assessment of Transplant Renal Artery Stenosis with Non-contrast-Enhanced Magnetic Resonance Angiography: Comparison with Digital Subtraction Angiography. Acad Radiol. 2023. PMID: 38142177. doi:10.1016/j.acra.2023.12.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。