基于人工智能的前列腺影像计算机辅助检测系统对常规工作流程和放射科医生结局的前瞻性影响
本研究在前列腺MRI阅片工作流程中新实施基于人工智能的计算机辅助检测系统,采用前瞻性前后对照设计,通过标准化工作观察和问卷调查评估91例阅片(实施前50例、实施后41例)。结果显示CAD实施后整体工作流程周转时间非显著增加(平均16.99±6.21 vs 18.77±9.69分钟,p=.51),高怀疑病例的诊断阅读时间增加(平均15.73±4.99 vs 23.07±8.75分钟,p=.02),放射科医生自报工作负荷或压力无变化。结论认为AI检测辅助的实施与标准化程度降低相关,对工作负荷或压力无随时间变化的影响,AI减轻放射科医生工作负荷的期望未得到真实世界研究证实。
要点
- CAD实施后高怀疑病例的诊断阅读时间增加(平均15.73±4.99 vs 23.07±8.75分钟,p=.02)。
- CAD实施后整体工作流程周转时间非显著增加(平均16.99±6.21 vs 18.77±9.69分钟,p=.51)。
- 放射科医生自报工作负荷或压力未发现变化。
核心结论
- 基于AI的检测辅助实施与标准化程度降低相关,对放射科医生工作负荷或压力无随时间变化的影响;AI减轻放射科医生工作负荷的期望未得到本真实世界研究证实。
研究设计与样本
- 前瞻性前后对照研究,在单一科室各观察三个月,共纳入91例观察的阅片(实施前50例、实施后41例),使用标准化工作观察和问卷调查,采用线性混合模型进行效应识别。
诊断标准与关键数值
- 记录工作流程周转时间、PI-RADS评分、CAD使用情况及放射科医生自报工作负荷和压力。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Artificial intelligence (AI) is expected to alleviate the negative consequences of rising case numbers for radiologists. Currently, systematic evaluations of the impact of AI solutions in real-world radiological practice are missing. Our study addresses this gap by investigating the impact of the clinical implementation of an AI-based computer-aided detection system (CAD) for prostate MRI reading on clinicians' workflow, workflow throughput times, workload, and stress.
MATERIALS AND METHODS: CAD was newly implemented into radiology workflow and accompanied by a prospective pre-post study design. We assessed prostate MRI case readings using standardized work observations and questionnaires. The observation period was three months each in a single department. Workflow throughput times, PI-RADS score, CAD usage and radiologists' self-reported workload and stress were recorded. Linear mixed models were employed for effect identification.
RESULTS: In data analyses, 91 observed case readings (pre: 50, post: 41) were included. Variation of routine workflow was observed following CAD implementation. A non-significant increase in overall workflow throughput time was associated with CAD implementation (mean 16.99 ± 6.21 vs 18.77 ± 9.69 min, p = .51), along with an increase in diagnostic reading time for high suspicion cases (mean 15.73 ± 4.99 vs 23.07 ± 8.75 min, p = .02). Changes in radiologists' self-reported workload or stress were not found.
CONCLUSION: Implementation of an AI-based detection aid was associated with lower standardization and no effects over time on radiologists' workload or stress. Expectations of AI decreasing the workload of radiologists were not confirmed by our real-world study.
PRE-REGISTRATION: German register for clinical trials https://drks.de/; DRKS00027391.
引用
- Wenderott K, Krups J, Luetkens JA, et al. Prospective effects of an artificial intelligence-based computer-aided detection system for prostate imaging on routine workflow and radiologists' outcomes. Eur J Radiol. 2023. PMID: 38096741. doi:10.1016/j.ejrad.2023.111252
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。