文献速递腹部技术与安全CT

双层双能CT小肠造影虚拟单能图像在克罗恩病内部穿透性并发症术前评估中的价值

Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn's disease.
PubMed 文献 · Abdom Radiol (NY) · 2023-12-27

回顾性纳入38例经手术证实的克罗恩病穿透性病变患者,行对比增强双层双能CT小肠造影,重建常规多能图像(PEI)与40–70 keV低能级虚拟单能图像(VMI),比较图像质量与病变检出能力。VMI40被确定为最佳低能级VMI,对穿透性病变总体检出与PEI无显著差异(p=1.0),但在肠管起源、瘘管累及器官或结构及瘘口与累及器官或结构相连处的检出上差异显著,VMI40有助于结直肠外科医生制定术前计划。

要点

  • VMI40是低能级VMI中图像质量最佳者,被确定为最佳虚拟单能图像。
  • VMI40与PEI对穿透性病变的总体检出能力无显著差异(p=1.0)。
  • VMI40在肠管起源、瘘管累及器官或结构及瘘口连接处的检出能力与PEI差异显著。

核心结论

  • 与常规PEI相比,VMI40提高了对克罗恩病穿透性病变解剖细节的检出能力,有助于结直肠外科医生合理化内部穿透性病变的术前计划。

研究设计与样本

  • 回顾性纳入38例经手术证实为克罗恩病穿透性病变的患者,均行对比增强双层双能CT小肠造影,重建PEI及40–70 keV(10 keV间隔)低能级VMI,比较客观图像质量参数(噪声、SNR、CNR)与主观图像质量参数(病变诊断表现DPL、整体图像质量OIQ)以确定最佳能级VMI,并比较PEI与最佳VMI的病变检出能力。

诊断标准与关键数值

  • VMI40被确定为低能级VMI中的最佳VMI,因其拥有最佳图像质量。
  • VMI40与PEI对穿透性病变的检出能力无显著差异(p=1.0)。
  • VMI40与PEI对穿透性病变肠管起源的检出能力差异显著(p=0.004)。
  • VMI40与PEI对瘘管累及器官或结构的检出能力差异显著(p=0.016)。
  • VMI40与PEI对瘘口与累及器官或结构相连处的检出能力差异显著(p=0.031)。

临床应用与阅片要点

  • 作者认为VMI40较常规PEI提高了对克罗恩病穿透性病变解剖细节的检出能力,有助于结直肠外科医生合理化术前计划。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: To determine the utility of virtual-monoenergetic imaging (VMI) at low energy levels from contrast-enhanced dual-layer dual-energy (DLDE) computed tomography enterography (CTE) in the preoperative assessment of internal penetrating lesions of Crohn's disease (CD).

MATERIALS AND METHODS: Thirty-eight patients with penetrating lesions of CD by surgery undergoing contrast-enhanced DLDE CTE were retrospectively included. Polyenergetic imaging (PEI) and VMIs at low energy levels [40-70 kiloelectron volts (keV)] with 10 keV intervals were reconstructed. The objective parameters of image quality [noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] and the subjective parameter of image quality [diagnostic performance of lesions (DPL), overall image quality(OIQ)] of PEI and all VMIs at the low energy level were compared to determine the VMI on the optimal energy level. The lesion detection capability between PEI and the optimal VMI was compared.

RESULTS: VMI40 was determined to be the optimal VMI among all VMIs at the low energy level for owning the best image quality. No significant difference was found in the detecting capability in penetrating lesions between VMI40 and PEI (p = 1.0), whereas a significant difference was found in the detecting capability in the bowel origin of the penetrating lesions (p = 0.004), the involved organ or structure by the fistula (p = 0.016) and the orifice of the fistula connected to the involved organ or structure ( p = 0.031) between them.

CONCLUSIONS: Compared to conventional PEI, VMI40 improves the detection capability in anatomical details of penetrating lesions of CD, helping colorectal surgeons rationalizing preoperative plans of internal penetrating lesions of CD.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Gong M, Liu L, Ren H, et al. Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn's disease. Abdom Radiol (NY). 2023. PMID: 38150141. doi:10.1007/s00261-023-04148-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。