CT提取的骨骼肌质量低下与重症急性胰腺炎患者不良结局相关
纳入158例ICU入院时行CT的急性胰腺炎患者,于L2-3层面测量人体成分。重症组IMAT和VAT显著高于中度重症组但与结局无关;SMD每增加1 HU不良结局风险降低11%(校正OR 0.892,95%CI 0.806-0.987,P=0.026),SMD低于中位数(男32.1 HU、女28.5 HU)独立关联更差结局(校正OR 8.868,95%CI 2.146-36.650,P=0.003)。SMD预测结局AUC男性0.824(95%CI 0.715-0.933)、女性0.803(95%CI 0.639-0.967)。
要点
- L2-3层面平扫CT测量SMD,低于中位数(男32.1 HU、女28.5 HU)提示不良结局风险升高。
- SMD每升高1 HU,不良结局风险降低11%(校正OR 0.892)。
- SMD预测不良结局AUC男性0.824、女性0.803。
核心结论
- 低SMD与重症及中度重症急性胰腺炎患者的不良结局相关,可能作为预测该类患者结局的新标志物。
研究设计与样本
- 研究论文;纳入ICU入院时行CT扫描确诊的急性胰腺炎患者158例;于L2-3层面平扫CT单层测量人体成分,采用图像分析软件以HU评估IMAT、VAT、SMA和SMD;参考标准为临床结局(全因死亡或ICU住院延长)。
关键影像表现/征象
- 重症急性胰腺炎组IMAT 8.3 cm2 vs 中度重症组6.0 cm2(P=0.001),重症组较高。
- 重症急性胰腺炎组VAT 190.3 cm2 vs 中度重症组143.7 cm2(P<0.001),重症组较高。
- IMAT和VAT与结局无关联。
诊断标准与关键数值
- SMD每增加1 HU,不良临床结局风险降低11%(校正OR 0.892,95%CI 0.806-0.987,P=0.026)。
- SMD低于中位数(男性32.1 HU、女性28.5 HU)在多变量分析中独立关联更差结局(校正OR 8.868,95%CI 2.146-36.650,P=0.003)。
- SMD预测临床结局的AUC男性0.824(95%CI 0.715-0.933),女性0.803(95%CI 0.639-0.967)。
临床应用与阅片要点
- 作者认为低SMD可能作为预测重症及中度重症急性胰腺炎患者结局的新标志物。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the association between body composition parameters derived from computed tomography (CT) scans and clinical outcomes in patients with severe acute pancreatitis (AP).
METHODS: Patients who have been diagnosed AP with a CT scan at ICU admission were included. Body composition parameters were measured on a single slice at L2-3 of the unenhanced CT scans. The intermuscular adipose tissue (IMAT), visceral adipose tissue (VAT), skeletal muscle area (SMA) and skeletal muscle density (SMD) were assessed using HUs by image analysis software. Univariable and multivariable analyses were performed to analyze the association between body composition parameters and clinical outcomes including all-cause mortality or prolonged ICU stay. The area under the curve (AUC) of a receiver operating characteristic curve was used to explore the predictive value of the body composition on treatment clinical outcomes.
RESULTS: A total of 158 patients were included. The IMAT (8.3 cm2 vs 6.0 cm2, P = 0.001) and VAT (190.3 cm2 vs 143.7 cm2, P < 0.001) were significantly higher in the severe AP group than in the moderately severe group, but were notassociatedwithoutcomes. For 1 HU of SMD increased, the risk of poor clinical outcomes decresed 11 % (adjusted OR 0.892, 95 %CI 0.806-0.987, P = 0.026), while an SMD below the median value (32.1 HU for males and 28.5 HU for females) was independently associated with worse outcomes in the multivariable analysis (adjusted OR 8.868, 95 % CI 2.146-36.650, P = 0.003). The SMD had a good predictive ability for clinical outcomes, AUC was 0.824 (95 % CI, 0.715-0.933) for males and 0.803 (95 % CI, 0.639-0.967) for females.
CONCLUSION: Low SMD was associated with poor outcomes in patients with severe and moderately severe AP and might be used as a novel marker to predict outcomes in patients suffering from severe and moderately severe AP.
引用
- Wang S, Wang M, Jiang L, et al. Low skeletal muscle quality extracted from CT is associated with poor outcomes in severe acute pancreatitis patients. Eur J Radiol. 2023. PMID: 38091663. doi:10.1016/j.ejrad.2023.111215
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。