深度学习算法在肝细胞癌高危患者钆塞酸增强MRI三维T1加权梯度回波成像中的应用
本回顾性分析纳入83例肝细胞癌高危患者,在3T扫描仪上行钆塞酸增强肝脏MRI,比较常规重建与深度学习重建算法(DLRA)对图像质量和病灶检出的影响。DLRA重建图像在整体图像质量、对比度、病灶和血管清晰度及肝缘锐利度方面显著改善,并降低主观图像噪声、振铃和运动伪影(均P<0.05);非囊性局灶性肝病灶的FOM无显著差异,但DLRA重建图像在各期汇总敏感度更高(P<0.05),动脉期和肝胆期对治疗后存活肝细胞癌的检出率更高(均P<0.05)。
要点
- DLRA重建可显著改善钆塞酸增强肝脏MRI三维T1加权梯度回波序列的图像质量、对比度及病灶和血管清晰度(均P<0.05)。
- DLRA重建在各期汇总敏感度高于常规重建(P<0.05),动脉期和肝胆期对治疗后存活肝细胞癌检出率更高(均P<0.05)。
- 非囊性局灶性肝病灶的FOM在常规与DL方法间无显著差异。
核心结论
- 实施DLRA可改善钆塞酸增强肝脏MRI三维T1加权梯度回波序列的图像质量,并提高对治疗后存活肝细胞癌的检出。
研究设计与样本
- 回顾性分析,纳入83例肝细胞癌高危患者,使用3T扫描仪行钆塞酸增强肝脏MRI,采集三重动脉期、高分辨率门静脉期和高分辨率肝胆期图像,分别用常规重建技术和DLRA(AIRTM Recon DL;GE Healthcare)重建后比较;由三名腹部放射科医师评估图像质量和实性局灶性病灶检出,病灶检出采用jackknife替代自由响应受试者工作特征分析(JAFROC)的品质因数(FOM)按病灶逐一评估。
关键影像表现/征象
- DLRA重建图像较常规重建图像显著改善整体图像质量、图像对比度、病灶清晰度、血管清晰度和肝缘锐利度(均P<0.05)。
- DLRA重建图像较常规重建图像降低主观图像噪声、振铃伪影和运动伪影(均P<0.05)。
诊断标准与关键数值
- 非囊性局灶性肝病灶的FOM在常规重建与DL方法间无显著差异。
- DLRA重建图像在各期汇总敏感度高于常规重建图像(P<0.05)。
- DLRA重建图像在动脉期和肝胆期对治疗后存活肝细胞癌的检出率高于常规重建图像(均P<0.05)。
临床应用与阅片要点
- 在钆塞酸增强肝脏MRI三维T1加权梯度回波序列中,DLRA重建可改善图像质量并提高各期汇总敏感度(P<0.05)。
- DLRA重建在动脉期和肝胆期对治疗后存活肝细胞癌的检出率高于常规重建(均P<0.05),阅片时可关注该序列对治疗后存活病灶的显示。
- 非囊性局灶性肝病灶的FOM在常规与DL方法间无显著差异,DLRA的主要获益在于图像质量和敏感度提升。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the efficacy of a vendor-specific deep learning reconstruction algorithm (DLRA) in enhancing image quality and focal lesion detection using three-dimensional T1-weighted gradient-echo images in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI) in patients at a high risk of hepatocellular carcinoma.
MATERIALS AND METHODS: In this retrospective analysis, 83 high-risk patients with hepatocellular carcinoma underwent gadoxetic acid-enhanced liver MRI using a 3-T scanner. Triple arterial phase, high-resolution portal venous phase, and high-resolution hepatobiliary phase images were reconstructed using conventional reconstruction techniques and DLRA (AIRTM Recon DL; GE Healthcare) for subsequent comparison. Image quality and solid focal lesion detection were assessed by three abdominal radiologists and compared between conventional and DL methods. Focal liver lesion detection was evaluated using figures of merit (FOMs) from a jackknife alternative free-response receiver operating characteristic analysis on a per-lesion basis.
RESULTS: DLRA-reconstructed images exhibited significantly improved overall image quality, image contrast, lesion conspicuity, vessel conspicuity, and liver edge sharpness and reduced subjective image noise, ringing artifacts, and motion artifacts compared to conventionally reconstructed images (all P < 0.05). Although there was no significant difference in the FOMs of non-cystic focal liver lesions between the conventional and DL methods, DLRA-reconstructed images showed notably higher pooled sensitivity than conventionally reconstructed images (P < 0.05) in all phases and higher detection rates for viable post-treatment HCCs in the arterial and hepatobiliary phases (all P < 0.05).
CONCLUSIONS: Implementing DLRA can enhance the image quality in 3D T1-weighted gradient-echo sequences of gadoxetic acid-enhanced liver MRI examinations, leading to improved detection of viable post-treatment HCCs.
引用
- Kim JH, Yoon JH, Kim SW, et al. Application of a deep learning algorithm for three-dimensional T1-weighted gradient-echo imaging of gadoxetic acid-enhanced MRI in patients at a high risk of hepatocellular carcinoma. Abdom Radiol (NY). 2023. PMID: 38095685. doi:10.1007/s00261-023-04124-4