文献速递腹部技术与安全US

基于5G的远程机器人超声系统为农村岛屿患者提供合格腹部超声服务:一项纳入401例患者的前瞻性对比研究

A 5G-based telerobotic ultrasound system provides qualified abdominal ultrasound services for patients on a rural island: a prospective and comparative study of 401 patients.
PubMed 文献 · Abdom Radiol (NY) · 2023-12-15

这项前瞻性研究纳入两个医疗中心(远程放射科医师所在医院与患者所在医院,相距72 km)的401例患者,于2020年9月至2021年3月分别接受基于5G的远程机器人腹部超声和常规腹部超声检查。远程机器人超声检查用时较常规超声更长(12.54±3.20 min vs 7.23±2.10 min,p=0.001),图像质量评分两组相似(4.54±0.63 vs 4.57±0.61,p=0.112),除肾脏横径测量被低估(p<0.05)外其余测量无显著差异,29种疾病诊断一致性良好(κ=0.773-1.000)。

要点

  • 远程机器人腹部超声与常规超声图像质量评分相似(4.54±0.63 vs 4.57±0.61,p=0.112)。
  • 除肾脏横径被低估(p<0.05)外,主动脉、门静脉、胆囊、肾脏长径、前列腺、子宫测量无显著差异。
  • 29种疾病诊断一致性良好(κ=0.773-1.000),90.1%患者表示远程机器人超声检查无不适。

核心结论

  • 基于5G的远程机器人超声系统可为农村地区患者扩大腹部超声服务可及性,从而减少医疗保健差距。

研究设计与样本

  • 前瞻性研究,纳入两个医疗中心(远程放射科医师所在医院与患者所在医院,相距72 km)的401例患者(女217例、男184例;平均年龄54.96±15.43岁),于2020年9月至2021年3月由远程放射科医师行基于5G的远程机器人腹部超声、由现场放射科医师行常规腹部超声,基于安全性、检查时长、图像质量、诊断发现和问卷评估临床可行性与诊断效能。

关键影像表现/征象

  • 远程机器人超声检查用时较常规超声更长(12.54±3.20 min vs 7.23±2.10 min,p=0.001)。
  • 图像质量评分两种方法相似(4.54±0.63 vs 4.57±0.61,p=0.112)。
  • 主动脉、门静脉、胆囊、肾脏长径、前列腺、子宫测量两种方法无显著差异,但远程机器人超声低估肾脏横径(p<0.05)。
  • 共检出504个阳性结果、涵盖31种不同疾病,其中455例两种方法均检出、17例仅远程机器人超声检出、32例仅常规超声检出。

诊断标准与关键数值

  • 29种疾病诊断一致性良好(κ=0.773-1.000)。
  • 90.1%患者表示远程机器人超声检查无不适。
  • 超过90%患者接受远程机器人超声检查并同意未来支付额外费用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To explore the feasibility of a 5G-based telerobotic ultrasound (US) system for providing qualified abdominal US services on a rural island.

METHODS: This prospective study involved two medical centers (the tele-radiologist site's hospital and the patient site's hospital) separated by 72 km. Patients underwent 5G-based telerobotic US by tele-radiologists and conventional US by on-site radiologists from September 2020 to March 2021. The clinical feasibility and diagnostic performance of the 5G-based telerobotic abdominal US examination were assessed based on safety, duration, image quality, diagnostic findings, and questionnaires.

RESULTS: A total of 401 patients (217 women and 184 men; mean age, 54.96 ± 15.43 years) were enrolled. A total of 90.1% of patients indicated no discomfort with the telerobotic US examination. For the examination duration, telerobotic US took longer than conventional US (12.54 ± 3.20 min vs. 7.23 ± 2.10 min, p = 0.001). For image quality scores, the results of the two methods were similar (4.54 ± 0.63 vs. 4.57 ± 0.61, p = 0.112). No significant differences were found between the two methods in measurements for the aorta, portal vein, gallbladder, kidney (longitudinal diameter), prostate, and uterus; however, telerobotic US underestimated the transverse diameter of the kidney (p < 0.05). A total of 504 positive results, including 31 different diseases, were detected. Among them, 455 cases were identified by the two methods; 17 cases were identified by telerobotic US only; and 32 cases were identified by conventional US only. There was good consistency in the diagnosis of 29 types of disease between the two methods (κ = 0.773-1.000). Furthermore, more than 90% of patients accepted the telerobotic US examination and agreed to pay additional fees in future.

CONCLUSION: The 5G-based telerobotic US system can expand access to abdominal US services for patients in rural areas, thereby reducing health care disparities.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhang YQ, Sun LP, He T, et al. A 5G-based telerobotic ultrasound system provides qualified abdominal ultrasound services for patients on a rural island: a prospective and comparative study of 401 patients. Abdom Radiol (NY). 2023. PMID: 38102443. doi:10.1007/s00261-023-04123-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。