回顾性纳入147例患者155个经病理证实的胰腺神经内分泌肿瘤病灶,按7:3分为训练组和验证组,用LASSO和PCA筛选CT特征,构建逻辑回归、支持向量机和K近邻三种机器学习模型。训练组逻辑回归AUC最高0.964,验证组支持向量机AUC最高0.952。机器学习方法可能有助于鉴别G1/G2与G3胰腺神经内分泌肿瘤。

要点

  • G3胰腺神经内分泌肿瘤更易表现为侵袭性行为且强化程度低于G1/G2。
  • 训练组逻辑回归分类器AUC 0.964,验证组支持向量机分类器AUC 0.952。
  • 机器学习方法可能有助于鉴别G1/G2与G3胰腺神经内分泌肿瘤。

核心结论

  • 逻辑回归和支持向量机分类器分别在训练组和验证组表现最佳,机器学习方法可能有助于鉴别G1/G2与G3胰腺神经内分泌肿瘤。

研究设计与样本

  • 回顾性纳入147例患者共155个经病理证实的胰腺神经内分泌肿瘤病灶,收集临床人口学和放射学CT特征,按7:3比例分为训练组和验证组,采用LASSO算法和主成分分析筛选特征,构建逻辑回归、支持向量机和K近邻三种机器学习模型。

关键影像表现/征象

  • G3胰腺神经内分泌肿瘤更可能表现为侵袭性行为,且强化程度低于G1/G2胰腺神经内分泌肿瘤。

诊断标准与关键数值

  • 训练组逻辑回归分类器AUC 0.964(95%CI 0.930, 0.972),准确率95.4%,敏感度95.7%,特异度92.9%;支持向量机AUC 0.957;K近邻AUC 0.893。验证组支持向量机分类器AUC 0.952(95%CI 0.860, 0.981),准确率91.5%,敏感度97.3%,特异度70%;逻辑回归AUC 0.949;K近邻AUC 0.923。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To identify CT features for distinguishing grade 1 (G1)/grade 2 (G2) from grade 3 (G3) pancreatic neuroendocrine tumors (PNETs) using different machine learning (ML) methods.

MATERIALS AND METHODS: A total of 147 patients with 155 lesions confirmed by pathology were retrospectively included. Clinical-demographic and radiological CT features was collected. The entire cohort was separated into training and validation groups at a 7:3 ratio. Least absolute shrinkage and selection operator (LASSO) algorithm and principal component analysis (PCA) were used to select features. Three ML methods, namely logistic regression (LR), support vector machine (SVM), and K-nearest neighbor (KNN) were used to build a differential model. Receiver operating characteristic (ROC) curves and precision-recall curves for each ML method were generated. The area under the curve (AUC), accuracy rate, sensitivity, and specificity were calculated.

RESULTS: G3 PNETs were more likely to present with invasive behaviors and lower enhancement than G1/G2 PNETs. The LR classifier yielded the highest AUC of 0.964 (95% confidence interval [CI]: 0.930, 0.972), with 95.4% accuracy rate, 95.7% sensitivity, and 92.9% specificity, followed by SVM (AUC: 0.957) and KNN (AUC: 0.893) in the training group. In the validation group, the SVM classier reached the highest AUC of 0.952 (95% CI: 0.860, 0.981), with 91.5% accuracy rate, 97.3% sensitivity, and 70% specificity, followed by LR (AUC: 0.949) and KNN (AUC: 0.923).

CONCLUSIONS: The LR and SVM classifiers had the best performance in the training group and validation group, respectively. ML method could be helpful in differentiating between G1/G2 and G3 PNETs.

来源:Acad Radiol,查看原文。版权归原作者所有。