影像组学与肝转移瘤治疗反应的相关性研究
本研究纳入203例乳腺癌肝转移女性患者,基于RECIST 1.1将随访CT分为稳定组66例、部分缓解组69例和进展组68例,对基线与随访CT肝转移灶行半自动分割提取影像组学特征。结果显示随访CT影像组学可区分稳定与部分缓解(随机森林AUC 0.845)及稳定与进展(AUC 0.731),但基线影像组学在三组间无差异,无法预测治疗反应。
要点
- 随访CT影像组学可区分稳定与部分缓解(AUC 0.845)及稳定与进展(AUC 0.731)。
- 基线影像组学在稳定、部分缓解、进展三组间无差异,不能预测治疗反应。
- 稳定组基线及随访CT影像组学无显著差异(AUC 0.3)。
核心结论
- 基于半自动分割的肝转移瘤影像组学在随访CT上可区分稳定与部分缓解及进展,但基线影像组学不能预测治疗反应。
研究设计与样本
- 经IRB批准的影像组学研究纳入203例乳腺癌肝转移女性(平均年龄54±11岁),于基线及治疗后3至12个月随访行腹部-盆腔门静脉期增强CT,按RECIST 1.1分为稳定66例、部分缓解69例、进展68例,行半自动分割提取一阶及高阶影像组学特征并以逻辑回归和随机森林分类器分析。
诊断标准与关键数值
- 随机森林分类器区分部分缓解的AUC为0.845,最相关特征为灰度依赖矩阵的大依赖强调高低通小波滤波特征。
- 随机森林分类器区分进展的AUC为0.731,最相关特征为表面积与体积比。
- 稳定组基线及随访CT影像组学无显著差异,AUC为0.3。
- 基线影像组学在三组间无差异,因此无法预测治疗反应。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To assess differences in radiomics derived from semi-automatic segmentation of liver metastases for stable disease (SD), partial response (PR), and progressive disease (PD) based on RECIST1.1 and to assess if radiomics alone at baseline can predict response.
MATERIALS AND METHODS: Our IRB-approved study included 203 women (mean age 54 ± 11 years) with metastatic liver disease from breast cancer. All patients underwent contrast abdomen-pelvis CT in the portal venous phase at two points: baseline (pre-treatment) and follow-up (between 3 and 12 months following treatment). Patients were subcategorized into three subgroups based on RECIST 1.1 criteria (Response Evaluation Criteria in Solid Tumors version 1.1): 66 with SD, 69 with PR, and 68 with PD on follow-up CT. The deidentified baseline and follow-up CT images were exported to the radiomics prototype. The prototype enabled semi-automatic segmentation of the target liver lesions for the extraction of first and high order radiomics. Statistical analyses with logistic regression and random forest classifiers were performed to differentiate SD from PD and PR.
RESULTS: There was no significant difference between the radiomics on the baseline and follow-up CT images of patients with SD (area under the curve (AUC): 0.3). Random forest classifier differentiated patients with PR with an AUC of 0.845. The most relevant feature was the large dependence emphasis's high and low pass wavelet filter (derived gray level dependence matrix features). Random forest classifier differentiated PD with an AUC of 0.731, with the most relevant feature being the surface-to-volume ratio. There was no difference in radiomics among the three groups at baseline; therefore, a response could not be predicted.
CONCLUSION: Radiomics of liver metastases with semi-automatic segmentation demonstrate differences between SD from PR and PD.
SUMMARY STATEMENT: Semiautomatic segmentation and radiomics of metastatic liver disease demonstrate differences in SD from the PR and progressive metastatic on the baseline and follow-up CT. Despite substantial variations in the scanners, acquisition, and reconstruction parameters, radiomics had an AUC of 0.84-0.89 for differentiating stable hepatic metastases from decreasing and increasing metastatic disease.
引用
- Mostafavi L, Homayounieh F, Lades F, et al. Correlation of Radiomics with Treatment Response in Liver Metastases. Acad Radiol. 2023. PMID: 38087718. doi:10.1016/j.acra.2023.11.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。