文献速递心血管CT

第二代运动校正算法对心肌桥合并壁冠状动脉患者冠状动脉CT血管成像图像质量与测量可重复性的影响

Effect of a second-generation motion correction algorithm on image quality and measurement reproducibility of coronary CT angiography in patients with a myocardial bridge and mural coronary artery.
PubMed 文献 · Clin Radiol · 2023-12-13

纳入66例左前降支心肌桥合并壁冠状动脉患者,行256排CT单心跳采集,于45%和75% R-R间期分别用标准(STD)、第一代(MC1)和第二代(MC2)运动校正算法重建。MC2较STD和MC1显著提高心肌桥和壁冠状动脉的图像质量与可解释性,并缩小组间测量一致性界限。

要点

  • MC2在45%和75% R-R间期均较STD和MC1提高壁冠状动脉与心肌桥的图像质量评分。
  • MC1显示壁冠状动脉优于STD,但显示心肌桥与STD无统计学差异(p>0.05)。
  • MC2在45%和75% R-R间期均使测量值的观察者间一致性界限更窄。

核心结论

  • 与STD和MC1相比,MC2提高心肌桥合并壁冠状动脉患者的CT图像质量和测量可重复性。

研究设计与样本

  • 共纳入66例左前降支心肌桥合并壁冠状动脉患者,行256排CT单心跳采集,于45%和75% R-R间期用STD、MC1和MC2算法重建,由两名观察者以4分法(1=差,4=优)评估图像质量。

关键影像表现/征象

  • 45% R-R间期壁冠状动脉图像质量评分:STD 1.59±0.78、MC1 2.21±0.97、MC2 3.21±0.62。
  • 45% R-R间期心肌桥图像质量评分:STD 2.48±0.79、MC1 2.76±0.75、MC2 3.58±0.58。
  • 75% R-R间期壁冠状动脉图像质量评分:STD 2.26±0.60、MC1 3.03±0.89、MC2 3.59±0.55。
  • 75% R-R间期心肌桥图像质量评分:STD 3.00±0.93、MC1 3.17±0.83、MC2 3.80±0.44。
  • MC1显示壁冠状动脉优于STD,但显示心肌桥与STD无统计学差异(p>0.05)。

诊断标准与关键数值

  • 图像质量采用4分法评估:1=差,4=优。
  • 测量指标包括心肌桥深度和长度、壁冠状动脉管腔面积和最小直径。

临床应用与阅片要点

  • 对心肌桥合并壁冠状动脉患者,MC2在45%和75% R-R间期均可提高图像质量和可解释性。
  • MC2在45%和75% R-R间期均使测量值的观察者间一致性界限更窄。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To determine the effect of second-generation motion correction (MC2) on image quality and measurement reproducibility of cardiac CT images in patients with a myocardial bridge and mural coronary artery (MB-MCA) compared to standard (STD) images without motion correction and with first-generation motion correction (MC1).

MATERIALS AND METHODS: A total of 66 patients with MB-MCA in the left anterior descending branch who underwent 256-detector CT with single-heartbeat acquisition were included. Images were reconstructed at 45% and 75% R-R intervals using STD, MC1, and MC2 algorithms. Image quality for MB-MCA was assessed by two observers on a four-point scale (1 = poor and 4 = excellent) and compared among STD, MC1, and MC2. Depth and length of MB, lumen area, and minimal diameter of MCA were measured and compared.

RESULTS: At 45% R-R interval, image quality scores were 1.59 ± 0.78, 2.21 ± 0.97, and 3.21 ± 0.62 for MCA, and 2.48 ± 0.79, 2.76 ± 0.75, and 3.58 ± 0.58 for MB with STD, MC1 and MC2, respectively. At 75% R-R interval, these values were 2.26 ± 0.60, 3.03 ± 0.89, and 3.59 ± 0.55 for MCA and 3.00 ± 0.93, 3.17 ± 0.83, and 3.80 ± 0.44 for MB. Although MC1 was superior to STD in displaying MCA, there was no statistical difference between the two algorithms for MB (p>0.05). Compared with STD and MC1, MC2 statistically improved image quality and interpretability for both MCA and MB and had narrower limits in interobserver agreement for measurements at both 45% and 75% R-R intervals.

CONCLUSION: MC2 improves CT image quality and measurement reproducibility in patients with MB-MCA compared to STD and MC1.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang Z, Liu Z, Hong N, et al. Effect of a second-generation motion correction algorithm on image quality and measurement reproducibility of coronary CT angiography in patients with a myocardial bridge and mural coronary artery. Clin Radiol. 2023. PMID: 38135576. doi:10.1016/j.crad.2023.11.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。