常规四维心脏CT识别重度主动脉瓣狭窄老年患者合并转甲状腺素蛋白淀粉样心肌病
这项前瞻性单中心筛查研究纳入263例考虑经导管主动脉瓣植入的重度主动脉瓣狭窄患者,在99mTc-DPD闪烁显像前约1天行四维心脏CT,评估CT衍生的左心室质量指数、左心室与左心房整体纵向应变及相对心尖纵向应变对合并转甲状腺素蛋白淀粉样心肌病的诊断效能,联合评分AUC为0.89,满足两条标准时敏感度96.3%、特异度58.9%。
要点
- 四维心脏CT衍生的左心室质量指数、左心室与左心房整体纵向应变、相对心尖纵向应变各自预测转甲状腺素蛋白淀粉样心肌病AUC均不低于0.70。
- 四项参数联合的无权重CT评分诊断转甲状腺素蛋白淀粉样心肌病AUC为0.89,内部自助法验证AUC为0.88。
- 满足两条CT评分标准时,检出转甲状腺素蛋白淀粉样心肌病的敏感度为96.3%、特异度为58.9%。
核心结论
- 以99mTc-DPD闪烁显像为参考标准,常规四维心脏CT通过评估左心室与左心房整体纵向应变、相对心尖纵向应变及左心室质量指数,在考虑经导管主动脉瓣植入的老年重度主动脉瓣狭窄患者中检出合并转甲状腺素蛋白淀粉样心肌病具有高诊断效能。
研究设计与样本
- 前瞻性单中心筛查研究,连续纳入2019年8月至2021年8月间考虑经导管主动脉瓣植入、并在99mTc-DPD闪烁显像前约1天接受四维心脏CT的重度主动脉瓣狭窄患者263例(平均年龄83岁±4.6[标准差],男149例、女114例)。
诊断标准与关键数值
- 99mTc-DPD闪烁显像Perugini 2级或3级确认合并转甲状腺素蛋白淀粉样心肌病27例(10.3%)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Transthyretin amyloid cardiomyopathy (ATTR-CM) often coexists with severe aortic stenosis (AS). Although strain analysis from cardiac MRI and echocardiography was demonstrated to predict coexisting ATTR-CM, comparable data from four-dimensional (4D) cardiac CT are lacking despite wide availability. Purpose To evaluate the diagnostic performance of 4D cardiac CT-derived parameters in identifying ATTR-CM in older adults considered for transcatheter aortic valve implantation (TAVI). Materials and Methods This prospective single-center screening study for ATTR-CM included consecutive patients with severe AS considered for TAVI who underwent 4D cardiac CT between August 2019 and August 2021 approximately 1 day before technetium 99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic-acid (DPD) scintigraphy. The diagnostic performance of CT-based left ventricular (LV), right ventricular, and left atrial dimensions, ejection fraction (EF), and myocardial strain were evaluated against 99mTc-DPD scintigraphy as the reference standard to identify ATTR-CM. Predictors and an unweighted cardiac CT score were validated with internal bootstrapping. The assignment of variables to the score was based on cutoff values achieving the highest Youden index J. Results Among 263 participants (mean age, 83 years ± 4.6 [SD]; 149 male and 114 female participants), 99mTc-DPD scintigraphy (Perugini grade 2 or 3) confirmed coexisting ATTR-CM in 27 (10.3%). CT-derived LV mass index, LV and LA global longitudinal strain (GLS), and relative apical longitudinal strain each predicted the presence of ATTR-CM with an area under the curve (AUC) of at least 0.70. Implementing these parameters with cutoff values of 81 g/m2 or higher, -14.9% or higher, less than 11.5%, and 1.7 or higher in the CT score, respectively, yielded high diagnostic performance (AUC = 0.89; 95% CI: 0.81, 0.94; P < .001) robust to internal bootstrapping validation (AUC = 0.88; 95% CI: 0.82, 0.94). If two criteria were fulfilled, the sensitivity and specificity in the detection of ATTR-CM were 96.3% (95% CI: 81.0, 99.9) and 58.9% (95% CI: 52.3, 65.2), respectively. Conclusion When compared against 99mTc-DPD scintigraphy as the reference standard, routine 4D cardiac CT in older adults considered for TAVI provided high diagnostic performance in the detection of concomitant ATTR-CM by assessing LV and left atrial GLS, relative apical longitudinal strain, and LV mass index. ClinicalTrials.gov registration no.: NCT04061213 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Tavakoli and Onder in this issue.
引用
- Bernhard B, Leib Z, Dobner S, et al. Routine 4D Cardiac CT to Identify Concomitant Transthyretin Amyloid Cardiomyopathy in Older Adults with Severe Aortic Stenosis. Radiology. 2023. PMID: 38085082. doi:10.1148/radiol.230425
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。