文献速递外周血管腹部技术与安全CT

基于计算机断层扫描的腹部主动脉瘤自动检测

Automated detection of incidental abdominal aortic aneurysms on computed tomography.
PubMed 文献 · Abdom Radiol (NY) · 2023-12-13

本研究使用在66例手动分割腹部CT上训练的全自动深度学习模型分割腹部主动脉并检测腹部主动脉瘤(AAA),在9172例无症状门诊CT结肠成像扫描中外部验证,检测AAA的敏感度96%(95%CI 89%,100%)、特异度96%(95%CI 96%,97%)、AUC 99%(95%CI 98%,99%),并发现AAA阳性与主动脉钙化斑块定量指标显著相关。

要点

  • 全自动深度学习模型在CT结肠成像外部验证集中检测AAA的AUC为99%(95%CI 98%,99%)。
  • 以最大轴位主动脉直径大于3 cm为AAA阳性标准时,模型敏感度96%、特异度96%。
  • 报告的AAA阳性病例主动脉Agatston评分和体积评分均显著高于AAA阴性病例(p < 0.0001)。

核心结论

  • 全自动深度学习在CT上检测和评估AAA是可行且准确的,AAA的存在与腹主动脉钙化动脉粥样硬化斑块的数量有很强的统计学关联。

研究设计与样本

  • 使用在来自两个数据集66例手动分割腹部CT上训练的全自动深度学习模型分割腹部主动脉,并在9172例因结直肠癌筛查转诊的无症状门诊患者CT结肠成像扫描上进行外部验证(平均年龄57岁);采用既往验证过的自动钙化动脉粥样硬化斑块检测器计算腹主动脉Agatston评分和体积评分并与AAA存在进行相关性分析。

诊断标准与关键数值

  • 以最大轴位主动脉直径大于3 cm为AAA阳性标准,深度学习软件在外部验证数据集检测AAA的敏感度96%(95%CI 89%,100%)、特异度96%(95%CI 96%,97%)、AUC 99%(95%CI 98%,99%);单用斑块作为AAA检测器时,在Agatston评分阈值2871处,敏感度84%(95%CI 73%,94%)、特异度87%(95%CI 86%,87%);报告的AAA阳性病例Agatston评分和体积评分均显著高于AAA阴性病例(p < 0.0001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To detect and assess abdominal aortic aneurysms (AAAs) on CT in a large asymptomatic adult patient population using fully-automated deep learning software.

MATERIALS AND METHODS: The abdominal aorta was segmented using a fully-automated deep learning model trained on 66 manually-segmented abdominal CT scans from two datasets. The axial diameters of the segmented aorta were extracted to detect the presence of AAAs-maximum axial aortic diameter greater than 3 cm were labeled as AAA positive. The trained system was then externally-validated on CT colonography scans of 9172 asymptomatic outpatients (mean age, 57 years) referred for colorectal cancer screening. Using a previously-validated automated calcified atherosclerotic plaque detector, we correlated abdominal aortic Agatston and volume scores with the presence of AAA.

RESULTS: The deep learning software detected AAA on the external validation dataset with a sensitivity, specificity, and AUC of 96%, (95% CI 89%, 100%), 96% (96%, 97%), and 99% (98%, 99%) respectively. The Agatston and volume scores of reported AAA-positive cases were statistically significantly greater than those of reported AAA-negative cases (p < 0.0001). Using plaque alone as a AAA detector, at a threshold Agatston score of 2871, the sensitivity and specificity were 84% (73%, 94%) and 87% (86%, 87%), respectively.

CONCLUSION: Fully-automated detection and assessment of AAA on CT is feasible and accurate. There was a strong statistical association between the presence of AAA and the quantity of abdominal aortic calcified atherosclerotic plaque.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Chatterjee D, Shen TC, Mukherjee P, et al. Automated detection of incidental abdominal aortic aneurysms on computed tomography. Abdom Radiol (NY). 2023. PMID: 38091064. doi:10.1007/s00261-023-04119-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。