先进与常规胸部MRI序列在系统性硬化症相关间质性肺病临床评估中与CT的对比:病变范围分析及与肺功能检查的相关性
研究纳入29例系统性硬化症相关间质性肺病(SSc-ILD)患者,比较T2径向TSE与PD UTE MRI序列与CT在ILD范围评估及与肺功能检查相关性中的表现。MRI与CT的ILD范围一致性CCC均为0.95,识别广泛病变的敏感度87.5%、特异度95.2%–100%,与FVC和DLCO的相关性与CT相似。结论认为MRI序列在确定SSc-ILD范围和严重程度方面可能具有与CT相似的准确性。
要点
- T2径向TSE与PD UTE MRI序列目测评估SSc-ILD范围与CT一致性高(CCC均为0.95)。
- 识别广泛ILD时径向TSE敏感度87.5%、特异度100%,UTE敏感度87.5%、特异度95.2%。
- MRI与CT的ILD范围均与FVC和DLCO呈负相关,相关系数相近。
核心结论
- MRI序列在确定SSc-ILD范围和严重程度方面可能具有与CT相似的准确性,且与肺功能检查的相关性类似。
研究设计与样本
- 29例SSc-ILD患者接受CT、MRI和肺功能检查,目测评估ILD范围,比较T2径向TSE与PD UTE MRI序列和CT。
关键影像表现/征象
- CT、径向TSE和UTE上的中位ILD范围分别为11%、11%和10%。
- CT与MRI的ILD范围一致性CCC均为0.95(Kruskal-Wallis p=0.64)。
诊断标准与关键数值
- 广泛ILD定义方法A:ILD>30%,或10%<ILD≤30%且FVC%<70%。
- 方法A下径向TSE识别广泛病变的敏感度87.5%、特异度100%、PPV 100%、NPV 95.5%、准确率96.6%;UTE为敏感度87.5%、特异度95.2%、PPV 87.5%、NPV 95.2%、准确率93.1%。
- 广泛ILD定义方法B:ILD>20%,或20%且FVC%<70%。
- 方法B下两种序列识别广泛病变均为敏感度86.7%、特异度86.4%、PPV 66.7%、NPV 95.0%、准确率86.2%。
- CT、径向TSE和UTE的ILD范围与FVC的Pearson r分别为-0.66、-0.60和-0.68,与DLCO分别为-0.59、-0.56和-0.57(p<0.002)。
临床应用与阅片要点
- MRI T2径向TSE和PD UTE序列可目测评估SSc-ILD范围,与CT一致性高且与肺功能相关。
- 原文未据此给出具体阅片推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: MRI is a radiation-free emerging alternative to CT in systemic sclerosis related interstitial lung disease (SSc-ILD) assessment. We aimed to compare a T2 radial TSE and a PD UTE MRI sequence with CT in SSc-ILD extent evaluation and correlations with pulmonary function tests (PFT).
MATERIAL AND METHODS: 29 SSc-ILD patients underwent CT, MRI and PFT. ILD extent was visually assessed. Lin's concordance correlation coefficients (CCC) and Kruskal Wallis test (p-value < 0.05) were computed for inter-method comparison. Patients were divided in limited and extended disease, defining extended ILD with two methods: (A) ILD>30% or 10%<ILD≤30% with FVC%<70%; (B) ILD>20% or 20% with FVC%<70%. MRI Sensitivity, Specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy were assessed. Pearson correlation coefficients r (p-value<0.025) were computed between ILD extents and PFT (FVC% and DLCO%).
RESULTS: Median ILD extents were 11%, 11%, 10% on CT, radial TSE and UTE, respectively. CCC between CT and MRI was 0.95 for both sequences (Kruskal-Wallis p-value=0.64). Sensitivity, Specificity, PPV, NPV and Accuracy in identifying extended disease were: (A) 87.5 %, 100 %, 100 %, 95.5 and 96.6 % with radial TSE and 87.5 %, 95.2 %, 87.5 %, 95.2 and 93.1 % with UTE; (B) 86.7 %, 86.4 %, 66.7 %, 95.0 % and 86.2 % for both sequences. Pearson r of CT, radial TSE and UTE ILD extents with FVC were -0.66, -0.60 and -0.68 with FVC, -0.59, -0.56 and -0.57 with DLCO, respectively (p<0.002).
CONCLUSIONS: MRI sequences may have similar accuracy to CT to determine SSc-ILD extent and severity, with analogous correlations with PFT.
引用
- Landini N, Orlandi M, Calistri L, et al. Advanced and traditional chest MRI sequence for the clinical assessment of systemic sclerosis related interstitial lung disease, compared to CT: disease extent analysis and correlations with pulmonary function tests. Eur J Radiol. 2023. PMID: 38056347. doi:10.1016/j.ejrad.2023.111239
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。