利用MRI推算的胎儿总肺容积观察值与预期值比值预测胎儿骨骼发育不良的致死性
本研究在80例胎儿骨骼发育不良病例中评估MRI推算的O/E-TFLV及超声指标对致死性(死产或生后1个月内死亡)的预测价值,发现O/E-TFLV<0.49和FL/AC<0.129是显著预测因子,O/E-TFLV<0.38时特异度达1.00。作者认为当超声预后不确定时,计算MRI推算的O/E-TFLV可为预后和分娩计划提供额外有用信息。
要点
- O/E-TFLV<0.49预测致死性的敏感度0.63、特异度0.93、AUC 0.81(P<0.001)。
- FL/AC<0.129预测致死性的敏感度0.73、特异度0.88、AUC 0.78(P<0.001)。
- O/E-TFLV<0.38时预测致死性的特异度达1.00。
核心结论
- MRI推算的O/E-TFLV和超声推算的FL/AC是胎儿骨骼发育不良致死性的显著预测因子;当超声后预后不确定时,计算MRI推算的O/E-TFLV可能为预后和分娩计划提供额外有用信息。
研究设计与样本
- 研究检索两个大型胎儿中心数据库,纳入80例骨骼发育不良胎儿,计算MRI推算的O/E-TFLV,并在有超声数据时纳入超声指标;以死产或生后1个月内死亡为致死性结局,采用逻辑回归和ROC曲线分析评估预测能力,P<0.05为统计学显著。
诊断标准与关键数值
- O/E-TFLV<0.49预测致死性:敏感度0.63、特异度0.93、AUC 0.81(P<0.001)。
- FL/AC<0.129预测致死性:敏感度0.73、特异度0.88、AUC 0.78(P<0.001)。
- O/E-TFLV<0.38时预测致死性的特异度为1.00。
- TC/AC和TC百分位不是致死性的显著危险因素。
临床应用与阅片要点
- 当超声评估胎儿骨骼发育不良预后不确定时,可计算MRI推算的O/E-TFLV以获取额外预后信息,用于预后咨询和分娩计划。
- O/E-TFLV<0.49与致死性风险显著相关,O/E-TFLV<0.38时特异度达1.00。
- 超声FL/AC<0.129也是致死性的显著预测指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Pulmonary hypoplasia is the primary cause of perinatal death in lethal skeletal dysplasias. The antenatal ultrasound correlates for lethality are indirect, measuring the thorax (thoracic circumference, TC) or femur compared to the abdomen (TC/AC, FL/AC). A single study has correlated lethality with the observed-to-expected total lung volume (O/E-TFLV) on fetal MRI in 23 patients.
OBJECTIVE: Our aim was to define a cutoff value to predict lethality more specifically using MRI-derived O/E-TFLV.
MATERIALS AND METHODS: Two large fetal center databases were searched for fetuses with skeletal dysplasia and MRI; O/E-TFLV was calculated. Ultrasound measures were included when available. Each was evaluated as a continuous variable against lethality (stillbirth or death in the first month of life). Logistic regression and receiver operating characteristic (ROC) curve analyses evaluated the prediction ability. AUC, sensitivity, and specificity were calculated. P < 0.05 was considered statistically significant.
RESULTS: A total of 80 fetuses met inclusion criteria. O/E-TFLV < 0.49 was a significant risk factor in predicting lethality, with sensitivity and specificity of 0.63 and 0.93, respectively, and an AUC of 0.81 (P < 0.001). FL/AC < 0.129 was also a strong variable with sensitivity, specificity, and AUC of 0.73, 0.88, and 0.78, respectively (P < 0.001). TC/AC and TC percentile were not significant risk factors for lethality. An O/E-TFLV of < 0.38 defines a specificity for lethality at 1.00.
CONCLUSION: MRI-derived O/E-TFLV and US-derived FL/AC are significant predictors of lethality in fetuses with skeletal dysplasia. When prognosis is uncertain after ultrasound, calculation of MRI-derived O/E-TFLV may provide additional useful information for prognosis and delivery planning.
引用
- Mehollin-Ray AR, Stover S, Cassady CI, et al. Using MRI-derived observed-to-expected total fetal lung volume to predict lethality in fetal skeletal dysplasia. Pediatr Radiol. 2023. PMID: 38052986. doi:10.1007/s00247-023-05825-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。