用于肺间质综合征的自动超声信号指标的开发
本研究为前瞻性研究,对12例急性心源性肺水肿患者和4例健康对照进行10区肺超声检查,共采集160个视频片段并同步收集射频信号,分析信号振幅时间变异性和频谱等特征。两个射频信号特征与B线存在强相关,组合指标的敏感度为93.2%、特异度为58.5%,交叉验证AUC为0.91(95%CI=0.80-0.94),旨在用于单阵元非成像可穿戴自动肺超声传感器连续监测肺液。
要点
- 组合射频信号指标诊断B线的敏感度93.2%、特异度58.5%、交叉验证AUC 0.91(95%CI=0.80-0.94)。
- 深部信号振幅时间变异性和胸膜线处信号振幅时间变异性与B线存在强相关。
- 该信号指标面向单阵元非成像可穿戴自动肺超声传感器,用于连续无手持监测肺液。
核心结论
- 开发了用于单阵元非成像肺超声传感器的组合信号指标,以促进呼吸疾病患者肺液的连续监测。
研究设计与样本
- 前瞻性研究,纳入16名参与者(12例急性心源性肺水肿患者,平均年龄60±12岁;4例健康对照,平均年龄44±21岁),行10区肺超声检查,共记录160个肺超声视频片段;使用开放平台超声系统驱动的相控阵探头同步采集射频信号,离线分析候选B线指标,以盲法独立阅片判断B线有无作为参考标准。
关键影像表现/征象
- 深部信号振幅时间变异性和胸膜线处信号振幅时间变异性两个射频信号特征与B线存在强相关。
诊断标准与关键数值
- 组合指标的敏感度为93.2%、特异度为58.5%,交叉验证AUC为0.91(95%CI=0.80-0.94)。
临床应用与阅片要点
- 该组合信号指标设计用于单阵元非成像可穿戴自动肺超声传感器,以促进呼吸疾病患者肺液的连续监测。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The number and distribution of lung ultrasound (LUS) imaging artifacts termed B-lines correlate with the presence of acute lung disease such as infection, acute respiratory distress syndrome (ARDS), and pulmonary edema. Detection and interpretation of B-lines require dedicated training and is machine and operator-dependent. The goal of this study was to identify radio frequency (RF) signal features associated with B-lines in a cohort of patients with cardiogenic pulmonary edema. A quantitative signal indicator could then be used in a single-element, non-imaging, wearable, automated lung ultrasound sensor (LUSS) for continuous hands-free monitoring of lung fluid.
METHODS: In this prospective study a 10-zone LUS exam was performed in 16 participants, including 12 patients admitted with acute cardiogenic pulmonary edema (mean age 60 ± 12 years) and 4 healthy controls (mean age 44 ± 21). Overall,160 individual LUS video clips were recorded. The LUS exams were performed with a phased array probe driven by an open-platform ultrasound system with simultaneous RF signal collection. RF data were analyzed offline for candidate B-line indicators based on signal amplitude, temporal variability, and frequency spectrum; blinded independent review of LUS images for the presence or absence of B-lines served as ground truth. Predictive performance of the signal indicators was determined with receiving operator characteristic (ROC) analysis with k-fold cross-validation.
RESULTS: Two RF signal features-temporal variability of signal amplitude at large depths and at the pleural line-were strongly associated with B-line presence. The sensitivity and specificity of a combinatorial indicator were 93.2 and 58.5%, respectively, with cross-validated area under the ROC curve (AUC) of 0.91 (95% CI = 0.80-0.94).
CONCLUSION: A combinatorial signal indicator for use with single-element non-imaging LUSS was developed to facilitate continuous monitoring of lung fluid in patients with respiratory illness.
引用
- Khokhlova TD, Thomas GP, Hall J, et al. Development of an Automated Ultrasound Signal Indicator of Lung Interstitial Syndrome. J Ultrasound Med. 2023. PMID: 38050780. doi:10.1002/jum.16383
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。