动态对比增强CT淋巴管造影定量胸导管淋巴流量

Dynamic Contrast-enhanced CT Lymphangiography to Quantify Thoracic Duct Lymphatic Flow.
PubMed 文献 · Radiology · 2023-01-01

研究在猪模型中开发并验证了基于动态对比增强CT淋巴管造影的胸导管淋巴流量测量技术,包括基于单室模型的首过分析法和区分胸导管内对比剂充盈与未充盈体素的阈值法。11头猪共71次动态CT采集显示,两种方法与US血流探头参考标准高度相关(r分别为0.99和0.91),Bland-Altman分析平均差异小(分别为0.04和0.05 mL/min),重复测量一致性良好。

要点

  • 首过分析法与US血流探头参考标准高度相关(r=0.99),阈值法r=0.91。
  • 两种CT技术与参考标准的Bland-Altman平均差异分别为0.04和0.05 mL/min。
  • 重复测量一致性良好,首过分析法r=0.94,阈值法r=0.90。

核心结论

  • 首过分析法和阈值法可基于动态对比增强CT淋巴管造影准确、无创地定量胸导管淋巴流量。

研究设计与样本

  • 动物实验(猪模型),于2021年11月至2022年9月进行,共11头猪(10头雄性;平均体重43.6 kg ± 2.6 [SD]),采用100 kV、200 mA快速螺距螺旋扫描模式覆盖全胸导管,双侧腹股沟淋巴结注射对比剂后采集动态CT图像,以手术放置于胸导管的US血流探头为参考标准。

诊断标准与关键数值

  • 首过分析法基于单室模型;阈值法区分胸导管内对比剂充盈与未充盈体素;于胸导管对比剂基础水平和峰值强化时采集两次螺旋CT扫描用于测量淋巴流量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background CT lymphangiography has been used to image the lymphatic anatomy and assess lymphatic abnormalities. There is, however, a need to develop a method for quantification of lymphatic flow rate in the thoracic duct (TD). Purpose To develop and validate a TD lymphatic flow measurement technique using dynamic contrast-enhanced CT lymphangiography. Materials and Methods Lymphatic flow rate was measured with two techniques: a first-pass analysis technique based on a single compartment model and a thresholding technique distinguishing between opacified and nonopacified voxels within the TD. The measurements were validated in a swine animal model between November 2021 and September 2022. CT images were acquired at 100 kV and 200 mA using a fast-pitched helical scan mode covering the entire TD following contrast material injection into the bilateral inguinal lymph nodes. Two helical CT scans, acquired at the base and peak contrast enhancement of the TD, were used to measure lymphatic flow rate. A US flow probe surgically placed around the TD provided the reference standard measurement. CT lymphatic flow measurements were compared with the reference US flow probe measurements using regression and Bland-Altman analysis. Repeatability was determined using repeated flow measurements within approximately 10 minutes of each other. Results Eleven swine (10 male; mean weight, 43.6 kg ± 2.6 [SD]) were evaluated with 71 dynamic CT acquisitions. The lymphatic flow rates measured using the first-pass analysis and thresholding techniques were highly correlated with the reference US flow probe measurements (r = 0.99 and 0.91, respectively) and showed good agreement with the reference standard, with Bland-Altman analysis showing small mean differences of 0.04 and 0.05 mL/min, respectively. The first-pass analysis and thresholding techniques also showed good agreement for repeated flow measurements (r = 0.94 and 0.90, respectively), with small mean differences of 0.09 and 0.03 mL/min, respectively. Conclusion The first-pass analysis and thresholding techniques could be used to accurately and noninvasively quantify TD lymphatic flow using dynamic contrast-enhanced CT lymphangiography. © RSNA, 2023 See also the editorial by Choyke in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Molloi S, Polivka AR, Zhao Y, et al. Dynamic Contrast-enhanced CT Lymphangiography to Quantify Thoracic Duct Lymphatic Flow. Radiology. 2023. PMID: 38112547. doi:10.1148/radiol.230959

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。