超声评估儿童眶内病变诊断与评价效用的回顾性分析
回顾23例同时接受超声和CT/MRI的儿童眶内病变患者,超声对病变检出率和特征判断准确率均为91.3%,未检出的2例均为骨外小病变,最长径10和11 mm。结论认为超声可用于眶内病变的观察和评估,但较小病变及骨后或骨侵犯病变无法检出。
要点
- 超声对儿童眶内病变的检出率和特征诊断准确率均为91.3%。
- 超声未检出的2例病变均位于骨外,最长径分别为10和11 mm。
- 超声检出病变的最长径均值29.5±8.2 mm,大于未检出病变的10和11 mm(P=.043)。
核心结论
- 超声对眶内病变的观察和评估有用,但无法检出相对较小的病变,也无法检出位于骨后及骨侵犯的病变。
研究设计与样本
- 回顾性分析,纳入23例同时接受超声和CT/MRI检查的儿童眶内病变患者,以CT/MRI为对照,采用Fisher精确检验和Mann-Whitney U检验比较。
关键影像表现/征象
- 超声评估病变位于肌锥内/肌锥外的比例在超声检出组为7/14,未检出组为0/2,两组间无显著差异(P>.999)。
- 超声未检出的2例病变均位于肌锥外。
- CT/MRI上最长径较小的病变超声未能检出,检出组最长径29.5±8.2 mm(范围13-46 mm),未检出组为10和11 mm(P=.043)。
诊断标准与关键数值
- 超声检出病变的准确率为91.3%(21/23)。
- 超声判断病变特征的准确率为91.3%(21/23)。
临床应用与阅片要点
- 超声可用于儿童眶内病变的观察和评估,但需注意较小病变可能无法检出。
- 对于位于骨后或存在骨侵犯的病变,超声无法检出。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the usefulness of ultrasonography in the diagnosis and evaluation of extraocular intra-orbital lesions in pediatric patients.
METHODS: Twenty-three pediatric patients with intra-orbital lesions who underwent both ultrasound and computed tomography/magnetic resonance imaging (CT/MRI) were included. The following parameters were evaluated using ultrasound: 1) lesion detection rate (presence or absence of lesions), 2) lesion characteristics, 3) lesion location (extraconal or intraconal), and 4) the lesion longest linear dimensions, and these were compared using Fisher's exact test and Mann-Whitney U test.
RESULTS: Two lesions could not be detected using ultrasound; in the other 21 cases, the lesion characteristics diagnosed by ultrasound were correct. Diagnostic accuracy of detection and characteristics assessment using ultrasound were 91.3% and 91.3%, respectively. The lesion location was not significantly different between the two groups (intraconal/extraconal in those detected using ultrasound versus those in the absence on ultrasound = 7/14 versus 0/2, P > .999); however, in two cases that were not detected on ultrasound, the lesions were located at extraconal. Lesions that were small in longest linear dimensions on CT/MRI were not detected using ultrasound (the longest linear dimensions in lesions detected using ultrasound versus that in the absence of ultrasound: 29.5 ± 8.2 [range, 13-46] versus 10 and 11 mm, P = .043).
CONCLUSIONS: Ultrasonography proved to be useful for visualizing and evaluating intra-orbital lesions except for lesions that were relatively small in size. Therefore, although ultrasound could not detect lesions located behind bone and bone invasion, it could be used for diagnosing and selecting treatment strategies for intra-orbital lesions.
引用
- Hosokawa T, Kuntaro D, Takei H, et al. Assessing the Usefulness of Ultrasonography for the Diagnosis and Evaluation of Intra-Orbital Lesions in Pediatric Patients: A Retrospective Analysis. J Ultrasound Med. 2023. PMID: 38124268. doi:10.1002/jum.16391
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。