基于多参数MRI的影像组学列线图预测鼻腔鼻窦内翻性乳头状瘤恶变
单中心回顾性研究纳入143例内翻性乳头状瘤(IP)和75例IP恶变为鳞状细胞癌(IP-SCC)患者,从CE-T1WI、T2WI和ADC图提取影像组学特征,结合临床独立危险因素构建列线图。列线图在训练集和验证集的AUC分别为0.993(95%CI 0.985-1.00)和0.990(95%CI 0.974-1.00),校准和区分度良好。
要点
- 鼻出血、T2等信号、鼻外侵犯和卷曲脑回模式消失是IP恶变的独立临床预测因素。
- 基于12个影像组学特征构建的模型AUC在训练集和验证集分别为0.987和0.989。
- 影像组学列线图预测IP-SCC的AUC训练集0.993、验证集0.990,校准和区分度良好。
核心结论
- 联合影像组学特征和临床危险因素的列线图对预测IP-SCC表现出满意的能力。
研究设计与样本
- 单中心回顾性研究,纳入143例IP和75例IP-SCC患者,均经手术病理证实,术前接受鼻窦MRI和CT检查(2014年6月至2022年2月)。从CE-T1WI、T2WI和ADC图提取影像组学特征,采用LASSO筛选,多因素logistic回归识别独立临床危险因素,构建列线图。
关键影像表现/征象
- T2等信号为独立临床预测因素(p=0.003)。
- 鼻外侵犯为独立临床预测因素(p<0.001)。
- 卷曲脑回模式消失为独立临床预测因素(p=0.002)。
诊断标准与关键数值
- 影像组学模型AUC在训练集和验证集分别为0.987和0.989。
- 列线图AUC训练集0.993(95%CI 0.985-1.00),验证集0.990(95%CI 0.974-1.00)。
- 鼻出血为独立临床预测因素(p=0.011)。
临床应用与阅片要点
- 结合鼻出血、T2等信号、鼻外侵犯和卷曲脑回模式消失等临床影像征象,可辅助评估IP恶变风险。
- 影像组学列线图基于CE-T1WI、T2WI和ADC图特征,可作为预测IP-SCC的辅助工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the feasibility of a radiomics nomogram model for predicting malignant transformation in sinonasal inverted papilloma (IP) based on radiomic signature and clinical risk factors.
MATERIALS AND METHODS: This single institutional retrospective review included a total of 143 patients with IP and 75 patients with IP with malignant transformation to squamous cell carcinoma (IP-SCC). All patients underwent surgical pathology and had preoperative magnetic resonance imaging (MRI) and computed tomography (CT) sinus studies between June 2014 and February 2022. Radiomics features were extracted from contrast-enhanced T1-weighted images (CE-T1WI), T2-weighted images (T2WI), and apparent diffusion coefficient (ADC) maps. The least absolute shrinkage and selection operator (LASSO) were performed to select the features extracted from the sequences mentioned above. Independent clinical risk factors were identified by multivariate logistic regression analysis. Radiomics nomogram was constructed by incorporating independent clinical risk factors and radiomics signature. Based on discrimination and calibration, the diagnostic performance of the nomogram was evaluated.
RESULTS: Twelve radiomics features were selected to develop the radiomics model with an area under the curve (AUC) of 0.987 and 0.989, respectively. Epistaxis (p=0.011), T2 equal signal (p=0.003), extranasal invasion (p<0.001), and loss of convoluted cerebriform pattern (p=0.002) were identified as independent clinical predictors. The radiomics nomogram model showed excellent calibration and discrimination (AUC: 0.993, 95% confidence interval [CI]: 0.985-1.00 and 0.990, 95% CI: 0.974-1.00) in the training and validation sets, respectively.
CONCLUSION: The nomogram that the combined radiomics signature and clinical risk factors showed a satisfactory ability to predict IP-SCC.
引用
- Xia Z, Lin N, Chen W, et al. Multiparametric MRI-based radiomics nomogram for predicting malignant transformation of sinonasal inverted papilloma. Clin Radiol. 2023. PMID: 38142140. doi:10.1016/j.crad.2023.11.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。