抗运动超快T2定量成像技术用于亚急性-慢性卒中远隔病灶患者表现正常皮质脊髓束微结构改变的定量检测
本研究纳入79例亚急性-慢性卒中患者行3.0 T MRI,采用多重重叠回波分离(MOLED)定量技术结合深度学习重建,在体模和志愿者中验证其准确性、可重复性和抗运动能力,并检测双侧表现正常皮质脊髓束(NA-CST)的T2值。结果显示患侧NA-CST的T2值显著高于对侧,患侧与对侧NA-CST的T2比值(rT2)与运动功能障碍严重程度正相关(rs=0.575,P<0.001),预测卒中后运动障碍的AUC为0.883。
要点
- MOLED技术平均变异系数1.11%,头动条件下平均差异0.28%、标准差差异1.34%。
- 患侧NA-CST的T2值显著高于对侧(P<0.001)。
- rT2与运动功能障碍严重程度正相关(rs=0.575,P<0.001),预测运动障碍AUC=0.883。
核心结论
- MOLED技术对存在不自主运动的卒中患者具有定量成像优势,其T2定量可检测NA-CST微结构改变,可能有助于监测卒中所致运动障碍。
研究设计与样本
- 79例患者行3.0 T MRI,包括常规扫描和MOLED技术,采用深度学习网络进行图像重建,并在体模和志愿者中验证MOLED的准确性、可靠性和抗运动能力。
关键影像表现/征象
- 患侧NA-CST的T2值显著高于对侧(P<0.001)。
- rT2与运动功能障碍严重程度呈正相关(rs=0.575,P<0.001)。
诊断标准与关键数值
- MOLED技术准确性高(P<0.001),平均变异系数(CoV)为1.11%。
- 头动条件下定量结果可靠,平均差异(Meandiff)=0.28%,标准差差异(SDdiff)=1.34%。
- rT2预测卒中后运动障碍的AUC为0.883。
临床应用与阅片要点
- MOLED技术可在患者不自主运动条件下提供可靠的定量T2结果。
- T2定量可检测NA-CST微结构改变,可能有助于监测卒中所致运动障碍。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Stroke patients commonly face challenges during magnetic resonance imaging (MRI) examinations due to involuntary movements. This study aims to overcome these challenges by utilizing multiple overlapping-echo detachment (MOLED) quantitative technology. Through this technology, we also seek to detect microstructural changes of the normal-appearing corticospinal tract (NA-CST) in subacute-chronic stroke patients.
MATERIALS AND METHODS: 79 patients underwent 3.0 T MRI scans, including routine scans and MOLED technique. A deep learning network was utilized for image reconstruction, and the accuracy, reliability, and resistance to motion of the MOLED technique were validated on phantoms and volunteers. Subsequently, we assessed motor dysfunction severity, ischemic lesion volume, T2 values of the bilateral NA-CST, and the T2 ratio (rT2) between the ipsilesional and contralesional NA-CST in patients.
RESULTS: The MOLED technique showed high accuracy (P < 0.001) and excellent repeatability, with a mean coefficient of variation (CoV) of 1.11%. It provided reliable quantitative results even under head movement, with a mean difference (Meandiff)= 0.28% and a standard deviation difference (SDdiff)= 1.34%. Additionally, the T2 value of the ipsilesional NA-CST was significantly higher than contralesional side (P < 0.001), and a positive correlation was observed between rT2 and the severity of motor dysfunction (rs =0.575, P < 0.001). Furthermore, rT2 successfully predicted post-stroke motor impairment, with an area under the curve (AUC) was 0.883.
CONCLUSION: The MOLED technique offers significant advantages for quantitatively imaging stroke patients with involuntary movements. Additionally, T2 mapping from MOLED can detect microstructural changes in the NA-CST, potentially aiding in monitoring stroke-induced motor impairment.
引用
- Zhang Y, Wang X, Ye M, et al. Anti-motion Ultrafast T2 Mapping Technique for Quantitative Detection of the Normal-Appearing Corticospinal Tract Changes in Subacute-Chronic Stroke Patients with Distal Lesions. Acad Radiol. 2023. PMID: 38142175. doi:10.1016/j.acra.2023.11.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。