基于T2加权MR影像的影像组学自动判定脊髓弥漫性中线胶质瘤H3 K27改变状态

Automated Determination of the H3 K27-Altered Status in Spinal Cord Diffuse Midline Glioma by Radiomics Based on T2-Weighted MR Images.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-01-01

本研究回顾性纳入97例脊髓弥漫性中线胶质瘤患者,从术前T2WI自动分割肿瘤中提取107个影像组学特征,经筛选后构建逻辑回归模型预测H3 K27改变状态;模型在测试集准确度0.833、AUC 0.839,在前瞻性验证集(28例)准确度0.786、AUC 0.818。

要点

  • 基于术前T2WI的影像组学模型可较准确预测脊髓弥漫性中线胶质瘤H3 K27改变状态,测试集AUC 0.839、前瞻性验证集AUC 0.818。
  • 模型在测试集准确度0.833、敏感度0.813、特异度0.857,前瞻性验证集分别为0.786、0.750、0.833。
  • 敏感性分析采用不同随机划分及其他分类器,预测准确度范围为0.767-0.833,支持模型稳健性。

核心结论

  • 基于术前T2WI的影像组学特征可较准确预测脊髓弥漫性中线胶质瘤的H3 K27改变状态,可能为临床管理提供潜在获益。

研究设计与样本

  • 回顾性研究,纳入97例确诊脊髓弥漫性中线胶质瘤患者,随机分为训练集(n=67)和测试集(n=30);另用28例患者的前瞻性集独立验证逻辑回归模型;从T2WI自动分割肿瘤中提取107个影像组学特征。

诊断标准与关键数值

  • 逻辑回归模型预测H3 K27改变状态:测试集准确度0.833、敏感度0.813、特异度0.857、AUC 0.839;前瞻性验证集准确度0.786、敏感度0.750、特异度0.833、AUC 0.818。
  • 敏感性分析中不同随机划分及其他分类器的预测准确度为0.767-0.833。
  • 特征筛选:从107个影像组学特征中经Pearson相关系数和Kruskal-Wallis检验选出11个特征用于建模。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Conventional MR imaging is not sufficient to discern the H3 K27-altered status of spinal cord diffuse midline glioma. This study aimed to develop a radiomics-based model based on preoperative T2WI to determine the H3 K27-altered status of spinal cord diffuse midline glioma.

MATERIALS AND METHODS: Ninety-seven patients with confirmed spinal cord diffuse midline gliomas were retrospectively recruited and randomly assigned to the training (n = 67) and test (n = 30) sets. One hundred seven radiomics features were initially extracted from automatically-segmented tumors on T2WI, then 11 features selected by the Pearson correlation coefficient and the Kruskal-Wallis test were used to train and test a logistic regression model for predicting the H3 K27-altered status. Sensitivity analysis was performed using additional random splits of the training and test sets, as well as applying other classifiers for comparison. The performance of the model was evaluated through its accuracy, sensitivity, specificity, and area under the curve. Finally, a prospective set including 28 patients with spinal cord diffuse midline gliomas was used to validate the logistic regression model independently.

RESULTS: The logistic regression model accurately predicted the H3 K27-altered status with accuracies of 0.833 and 0.786, sensitivities of 0.813 and 0.750, specificities of 0.857 and 0.833, and areas under the curve of 0.839 and 0.818 in the test and prospective sets, respectively. Sensitivity analysis confirmed the robustness of the model, with predictive accuracies of 0.767-0.833.

CONCLUSIONS: Radiomics signatures based on preoperative T2WI could accurately predict the H3 K27-altered status of spinal cord diffuse midline glioma, providing potential benefits for clinical management.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Li J, Wang Y, Weng J, et al. Automated Determination of the H3 K27-Altered Status in Spinal Cord Diffuse Midline Glioma by Radiomics Based on T2-Weighted MR Images. AJNR Am J Neuroradiol. 2023. PMID: 38081676. doi:10.3174/ajnr.A8056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。