全身磁共振成像与正电子发射断层扫描-计算机断层扫描在儿童淋巴瘤分期中的诊断准确性:系统综述与Meta分析
该系统综述与Meta分析共纳入7项研究,比较全身MRI与PET-CT对儿童淋巴瘤分期的诊断准确性。全身MRI分期的汇总敏感度为95.8%、特异度为21.8%、诊断比值比为1.19;结外分期的汇总敏感度为88.9%、特异度为97.4%、诊断比值比为25.29。全身MRI对儿童淋巴瘤分期具有高敏感度,可能成为PET-CT的有用替代方法。
要点
- 全身MRI对儿童淋巴瘤总体分期汇总敏感度为95.8%,但汇总特异度仅21.8%。
- 结外分期汇总敏感度88.9%、特异度97.4%、诊断比值比25.29,部分AUC为0.88。
- 7项纳入研究均存在偏倚风险(6项高风险、1项风险不明确)。
核心结论
- 全身MRI对儿童淋巴瘤分期具有高敏感度,可能成为PET-CT的有用替代方法。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Embase和Scopus数据库,最终纳入7项研究。
- 7项研究中有6项使用未增强全身MRI。
- 以PET-CT为参考标准,从纳入研究提取真阳性、真阴性、假阳性、假阴性数据构建2×2列联表。
- 采用QUADAS 2工具评估偏倚风险与适用性担忧。
诊断标准与关键数值
- 全身MRI基于分期的汇总敏感度为95.8%,汇总特异度为21.8%,诊断比值比为1.19。
- 结外分期的汇总敏感度为88.9%,汇总特异度为97.4%,诊断比值比为25.29。
- 总体分期的部分AUC为0.63,结外分期的部分AUC为0.88。
- QUADAS 2评估显示全部7项研究存在偏倚风险:6项高风险、1项风险不明确。
临床应用与阅片要点
- 全身MRI对儿童淋巴瘤分期具有高敏感度,可能作为PET-CT的替代方法,但总体分期特异度低需注意假阳性。
- 结外分期时全身MRI敏感度88.9%、特异度97.4%,诊断比值比25.29,部分AUC为0.88。
- 原文未据此给出推荐。
局限性
- 全部7项研究均存在偏倚风险,其中6项高风险、1项风险不明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Whole-body magnetic resonance imaging (MRI) has been investigated by multiple authors as a radiation-free alternative to positron emission tomography computed tomography (PET-CT) in children with lymphoma.
OBJECTIVE: To evaluate the sensitivity, specificity, and diagnostic odds ratio of whole-body MRI compared to PET-CT for the staging of pediatric lymphoma.
METHODS: The databases PubMed, Embase, and Scopus were searched for studies that reported the accuracy of whole-body MRI compared to PET-CT for lymphoma staging in children. Data was collected from included studies to formulate 2 × 2 contingency tables, including the number of true positive, true negative, false positive, and false negative. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated. Summary receiver operating characteristic curves were drawn and the area under the curve (AUC) calculated. In addition, the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS 2) tool was used to assess the risk of bias and applicability concerns.
RESULTS: A total of seven studies were included in the final analysis. Of these, six studies used unenhanced whole-body MRI. The pooled sensitivity of whole-body MRI-based staging was 95.8%, while the pooled specificity was 21.8%. The DOR for whole-body MRI was 1.19. For extranodal staging, the pooled sensitivity was 88.9%, specificity was 97.4%, and DOR was 25.29. The partial AUC for overall staging was 0.63, whereas that for extranodal staging stood at 0.88. Based on the QUADAS 2 tool, all seven studies were at risk of bias (six at high risk, one at unclear risk).
CONCLUSION: Whole-body MRI has high sensitivity for staging of pediatric lymphoma and may be a useful alternative to PET-CT.
引用
- Bhalla D, Jana M, Kandasamy D, et al. Diagnostic accuracy of whole-body magnetic resonance imaging versus positron emission tomography-computed tomography for the staging of pediatric lymphoma: a systematic review and meta-analysis. Pediatr Radiol. 2023. PMID: 37814104. doi:10.1007/s00247-023-05775-7