脑性瘫痪儿童的骨盆X线摄影:患者体位对计算移位百分比的影响

Pelvis radiographs in children with cerebral palsy: effects of patient positioning on calculating migration percentages.
PubMed 文献 · Pediatr Radiol · 2023-10-14

研究纳入63例脑性瘫痪(CP)患儿,利用骨盆CT生成模拟不同体位的数字重建X线片,由两名放射科医师测量移位百分比。结果显示测量者间信度高(Spearman's rho=0.86-0.99),但真实X线片与中立位模拟片的移位百分比存在显著差异(中位绝对差5-6个百分点),提示体位变化会降低测量准确度。

要点

  • 脑性瘫痪患儿骨盆正位X线片上移位百分比的测量者间信度高(Spearman's rho=0.86-0.99)。
  • 真实体位与中立位模拟片相比,移位百分比测量中位绝对差为5-6个百分点,差异有统计学意义(P<0.01)。
  • 中立位与后凸/前凸体位相比中位绝对差2-4个百分点,与右/左旋转相比中位绝对差4-15个百分点。

核心结论

  • 测量移位百分比的测量者间信度高,但准确度随患者体位变化而降低。

研究设计与样本

  • 回顾性研究,纳入2018年10月至2021年11月期间年龄≤18岁、骨盆CT与骨盆正位X线片检查间隔<6个月的脑性瘫痪患儿63例(男性41例,中位年龄8岁,范围4-18岁),由每例骨盆CT生成模拟九种体位的数字重建X线片,两名放射科医师测量模拟片及真实X线片的移位百分比。

诊断标准与关键数值

  • 两名放射科医师对所有模拟及真实X线片的移位百分比测量值高度相关(Spearman's rho=0.86-0.99,P<0.01);真实X线片与中立位模拟片的移位百分比测量值差异有统计学意义(P<0.01),中位绝对差5-6个百分点,四分位距9-12个百分点;中立位模拟片与后凸/前凸体位模拟片相比中位绝对差2-4个百分点(四分位距3-8个百分点),与右/左旋转体位模拟片相比中位绝对差4-15个百分点(四分位距6-17个百分点)。

临床应用与阅片要点

  • 在脑性瘫痪患儿骨盆正位X线片上测量移位百分比时,测量者间信度高,但真实体位与中立位之间的差异(中位绝对差5-6个百分点)以及不同体位(后凸/前凸、旋转)造成的差异(中位绝对差2-4及4-15个百分点)提示阅片和报告时应考虑体位对移位百分比准确度的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Hip displacement in children with cerebral palsy (CP) is monitored by measuring migration percentage on anteroposterior pelvis radiographs. However, proper positioning for radiography in children with spasticity is difficult. The reliability and accuracy of migration percentage as a function of patient positioning is unknown.

OBJECTIVE: To determine the effects of patient positioning on migration percentage measurements in children with CP.

MATERIALS AND METHODS: We identified children with CP (≤18-year-old) with pelvis CT and anteroposterior pelvis radiograph obtained <6 months apart (10/2018-11/2021). Digitally reconstructed radiographs were generated from each pelvis CT, to simulate nine different patient positions: neutral; 10° and 20° lordosis and kyphosis; and 10° and 20° right rotation and left rotation. Two radiologists measured migration percentages from the simulated and real pelvis radiographs. We used Spearman's rho to assess inter-rater reliability, and Wilcoxon signed rank test to determine statistical significance.

RESULTS: We studied sixty-three children (male=41; median age=8 years; range=4-18 years). The two radiologists' migration percentage measurements were highly correlated with each other across all simulated and real radiographs (Spearman's rho=0.86-0.99, P<0.01). For both readers and hips, migration percentages measured from real radiographs were significantly different from those measured from neutral simulated radiographs (P<0.01), with median absolute difference=5-6 percentage points (PP) and interquartile range (IQR)=9-12 PP. When comparing migration percentage measurements from neutral simulated radiographs to those in kyphosis/lordosis and right/left rotations, median absolute differences were 2-4 PP (IQR=3-8 PP) and 4-15 PP (IQR=6-17 PP), respectively.

CONCLUSION: Inter-rater reliability of measured migration percentages is high, but accuracy decreases with patient positional changes.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Jarrett DY, Stamoulis C, Shore BJ, et al. Pelvis radiographs in children with cerebral palsy: effects of patient positioning on calculating migration percentages. Pediatr Radiol. 2023. PMID: 37833504. doi:10.1007/s00247-023-05783-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。