文献速递骨肌US

肩峰下撞击综合征患者超声评估的诊断意义

Diagnostic Implications of Ultrasound Evaluation in Patients With Shoulder Impingement Syndrome.
PubMed 文献 · J Ultrasound Med · 2023-10-17

前瞻性横断面观察研究纳入30例肩峰下撞击综合征患者共60侧肩,用肌骨超声测量肩峰下囊厚度、冈上肌腱厚度、肩峰-肱骨距离及冈上肌腱与肩峰-肱骨距离比值(AHD%)。患侧冈上肌腱和肩峰下囊较对侧增厚、肩峰-肱骨距离变窄、AHD%增大;AHD%截断值65.6%和AHD×AHD%截断值0.504具有较好敏感度和特异度,有助于鉴别诊断。

要点

  • 患侧肩冈上肌腱和肩峰下囊较健侧增厚,肩峰-肱骨距离变窄,AHD%增大(P < .05)。
  • AHD%截断值65.6%、AHD×AHD%截断值0.504具有较好敏感度和特异度,可辅助鉴别肩峰下撞击综合征。
  • 受试者工作特征分析中AHD×AHD%诊断效能最佳,曲线下面积0.877。

核心结论

  • 肩峰下撞击综合征症状可能与冈上肌腱增厚伴AHD%增大相关;AHD%截断值65.6%和AHD×AHD%截断值0.504作为诊断标准具有较好敏感度和特异度,可帮助提高肩峰下撞击综合征患者的鉴别诊断。

研究设计与样本

  • 前瞻性横断面观察研究,纳入2019年1月至2020年1月收治的30例肩峰下撞击综合征患者共60侧肩,采用肌骨超声测量冈上肌腱厚度、肩峰下囊厚度、肩峰-肱骨距离及AHD%。

关键影像表现/征象

  • 患侧肩冈上肌腱和肩峰下囊较未患侧增厚(t = 7.838,P < .05)。
  • 患侧肩肩峰-肱骨距离较未患侧变窄(t = 2.324,P < .05)。
  • 患侧肩AHD%较未患侧增大(t = 6.875,P < .05)。
  • 患侧肩冈上肌腱厚度与肩峰-肱骨距离呈线性正相关(r = .503,P < .05),与AHD%呈线性正相关(r = .792,P < .05)。

诊断标准与关键数值

  • AHD%截断值65.6%,具有较好敏感度和特异度。
  • AHD×AHD%截断值0.504,具有较好敏感度和特异度。
  • 受试者工作特征分析中AHD×AHD%诊断效能最佳,曲线下面积0.877。
  • AHD%计算公式为AHD% = [(冈上肌腱厚度 / 肩峰-肱骨距离) × 100%]。

临床应用与阅片要点

  • 肌骨超声测量冈上肌腱厚度、肩峰下囊厚度、肩峰-肱骨距离并计算AHD%可用于评估肩峰下撞击综合征。
  • AHD%和AHD×AHD%的截断值可作为诊断参考,帮助提高肩峰下撞击综合征的鉴别诊断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic value of musculoskeletal ultrasound measurements of subacromial bursa (SAB) thickness, supraspinatus tendon (SUP) thickness, acromiohumeral distance (AHD), and SUP-to-AHD ratio (AHD%) in patients with shoulder impingement syndrome (SIS).

METHODS: This was a prospective cross-sectional observational study. Thirty patients with SIS (60 shoulders) admitted between January 2019 and January 2020 were enrolled. The SUP thickness, SAB thickness, AHD, and AHD% (calculated as AHD% = [(SUP / AHD) × 100%]) were measured in 60 shoulders using musculoskeletal ultrasound.

RESULTS: The affected shoulder displayed thicker SUP and SAB (t = 7.838), narrower AHD (t = 2.324), and larger AHD% (t = 6.875) than the unaffected shoulder (P < .05). The SUP thickness showed a linear positive correlation with AHD (r = .503) and AHD% (r = .792) in the affected shoulder (P < .05). On receiver operating characteristic analysis, AHD*AHD% showed the best diagnostic performance in both measurements (area under the curve: 0.877).

CONCLUSION: This study revealed that SIS symptoms may be related to a larger AHD% with SUP thickening. As diagnostic criteria, the cut-off values of AHD% (65.6%) and AHD*AHD% (0.504) have good sensitivity and specificity and can help improve the differential diagnosis of patients with SIS.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Du Y, Wang Z, Zhang T, et al. Diagnostic Implications of Ultrasound Evaluation in Patients With Shoulder Impingement Syndrome. J Ultrasound Med. 2023. PMID: 37846610. doi:10.1002/jum.16357

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。