弥散加权成像与磁共振波谱在鉴别乳腺良恶性病变中的诊断准确性比较:系统综述与荟萃分析
该系统综述与荟萃分析纳入8项诊断研究(632名女性,687个乳腺病变),以组织病理学为参考标准,比较DWI与MRS鉴别乳腺良恶性病变的敏感度和特异度。DWI合并敏感度92%、特异度88%,MRS分别为85%和85%,两者敏感度差异7%(CI -8-22%)、特异度差异3%(CI -9-14%)均无统计学显著性。基于低至中等质量证据,DWI与MRS在鉴别乳腺良恶性病变方面表现出相当的敏感度和特异度。
要点
- DWI鉴别乳腺良恶性病变的合并敏感度为92%、特异度为88%。
- MRS的合并敏感度为85%、特异度为85%。
- DWI与MRS的敏感度和特异度差异均无统计学显著性。
核心结论
- 基于低至中等质量证据,DWI与MRS在鉴别乳腺良恶性病变方面表现出相当的敏感度和特异度。
研究设计与样本
- 系统综述与荟萃分析,检索Scopus、PubMed等数据库至2023年4月,纳入8项以DWI和MRS为指标试验、组织病理学为参考标准的诊断研究,共632名女性、687个乳腺病变,采用随机效应双变量荟萃分析合并敏感度和特异度,QUADAS-2评估偏倚风险,GRADE总结证据质量。
诊断标准与关键数值
- DWI鉴别乳腺良恶性病变的合并敏感度为92%(CI 85-96%),合并特异度为88%(CI 75-94%)。
- MRS鉴别乳腺良恶性病变的合并敏感度为85%(CI 66-94%),合并特异度为85%(CI 77-91%)。
- DWI与MRS的敏感度差异为7%(CI -8-22%),特异度差异为3%(CI -9-14%),均无统计学显著性。
局限性
- 证据质量为低至中等。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the sensitivity and specificity of diffusion weighted imaging (DWI) and magnetic resonance spectroscopy (MRS) in the differentiation of benign and malignant breast lesions.
METHODS: Scopus, PubMed, and other registries were searched up to April 2023. We included diagnostic studies with DWI and MRS as index tests and histopathologic examination as the reference standard for differentiating benign and malignant breast lesions in adult females. We excluded studies involving healthy women, only breast cancer patients, and non-comparative diagnostic accuracy studies on either index test. The sensitivity and specificity of DWI and MRS were investigated and pooled using random-effect bivariate meta-analysis. Risk of bias was assessed using QUADAS-2. Evidence quality was summarized using GRADE.
RESULTS: Eight eligible studies involving 632 females and 687 breast lesions were identified. The pooled sensitivity and specificity of DWI were 92% (CI 85-96%) and 88% (CI 75-94%), respectively. The pooled sensitivity and specificity of MRS were 85% (CI 66-94%) and 85% (CI 77-91%), respectively. No significant difference was noted in the sensitivity (7%, CI -8-22%) and specificity (3%, CI -9-14%) between DWI and MRS.
CONCLUSIONS: In low to moderate quality evidence, DWI and MRS show comparable sensitivity and specificity in differentiating benign and malignant breast lesions.
引用
- Billy CA, Darmiati S, Prihartono J, et al. Diagnostic accuracy of diffusion weighted imaging compared to magnetic resonance spectroscopy in differentiation of benign and malignant breast lesions: A systematic review and meta-analysis. Eur J Radiol. 2023. PMID: 37820523. doi:10.1016/j.ejrad.2023.111124
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。