乳腺癌患者超声定位显微成像方案优化及其与剪切波弹性成像的比较
本研究对11例乳腺癌患者行超声定位显微成像(ULM),比较两种SonoVue剂量与注射速度方案,以出现图定量参数确定最佳注射方案和测量时间窗,并将ULM结果与剪切波弹性成像及组织学血管密度对比。较高剂量与注射速度获得最多微泡数、轨迹数和血管覆盖率,运动使可用帧数显著减少,测量窗限制为3.5 min;ULM血管覆盖率与组织学血管分数相当,并与平均肿瘤弹性显著相关。
要点
- 较高剂量与注射速度的SonoVue方案可获得最详细的肿瘤血管显示。
- 患者与检查者运动是ULM临床转化的主要挑战,测量窗限制为3.5 min。
- ULM血管覆盖率与组织学血管分数相当,并与平均肿瘤弹性显著相关。
核心结论
- 微泡注射设置强烈影响ULM图像,不同适应证需优化方案;患者与检查者运动是ULM临床转化的主要挑战。
研究设计与样本
- 对11例乳腺癌患者记录超声造影(CEUS)序列并行离线流程后处理生成ULM图像,采用两种不同SonoVue剂量与注射速度,以出现图定量参数确定最佳注射方案,并与剪切波弹性成像及组织学血管密度比较。
关键影像表现/征象
- 较高剂量与注射速度下微泡数、轨迹数和血管覆盖率最高,肿瘤血管显示最详细。
- 即使最高浓度下也未出现微泡信号显著重叠。
- 运动显著减少可用帧数,测量窗限制为3.5 min。
诊断标准与关键数值
- 最佳注射方案依据出现图衍生的定量参数确定。
- ULM血管覆盖率与组织学血管分数相当,并与平均肿瘤弹性显著相关。
局限性
- 患者与检查者运动被确定为ULM的主要转化挑战。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Ultrasound localization microscopy (ULM) has gained increasing attention in recent years because of its ability to visualize blood vessels at super-resolution. The field of oncology, in particular, could benefit from detailed vascular characterization, for example, for diagnosis and therapy monitoring. This study was aimed at refining ULM for breast cancer patients by optimizing the measurement protocol, identifying translational challenges and combining ULM and shear wave elastography.
METHODS: We computed ULM images of 11 patients with breast cancer by recording contrast-enhanced ultrasound (CEUS) sequences and post-processing them in an offline pipeline. For CEUS, two different doses and injection speeds of SonoVue were applied. The best injection protocol was determined based on quantitative parameters derived from so-called occurrence maps. In addition, a suitable measurement time window was determined, also considering the occurrence of motion. ULM results were compared with shear wave elastography and histological vessel density.
RESULTS: At the higher dose and injection speed, the highest number of microbubbles, number of tracks and vessel coverage were achieved, leading to the most detailed representation of tumor vasculature. Even at the highest concentration, no significant overlay of microbubble signals occurred. Motion significantly reduced the number of usable frames, thus limiting the measurement window to 3.5 min. ULM vessel coverage was comparable to the histological vessel fraction and correlated significantly with mean tumor elasticity.
CONCLUSION: The settings for microbubble injection strongly influence ULM images, thus requiring optimized protocols for different indications. Patient and examiner motion was identified as the main translational challenge for ULM.