文献速递乳腺US

人工智能计算机辅助检测软件对自动乳腺超声的诊断性能

Diagnostic Performance of Artificial Intelligence-Based Computer-Aided Detection Software for Automated Breast Ultrasound.
PubMed 文献 · Acad Radiol · 2023-10-07

本研究纳入2020年1月至2022年12月经组织病理学证实的262个自动乳腺超声(ABUS)检出的乳腺病灶,评估放射科医生使用人工智能(AI)计算机辅助检测(CAD)软件后的诊断性能。两位放射科医生以BI-RADS分类判读,并按四种方式结合AI结果调整BI-RADS分类;结果显示,仅根据AI结果直接修改BI-RADS分类(AI-aided 1)使AUC从0.870显著提高至0.919(P=0.001),其余三种调整方式AUC提高但无统计学显著性。

要点

  • AI-CAD可直接辅助放射科医生修改BI-RADS分类,使AUC从0.870提高至0.919(P=0.001)。
  • 仅上调AI阳性病灶或仅下调AI阴性病灶的BI-RADS分类,AUC提高但无统计学显著性。
  • AI-CAD阴性癌症病灶更小、较少出现回缩现象、BI-RADS分类更低;非肿块型AI-CAD阴性癌症无后方声影。

核心结论

  • AI-CAD的实施显著提高了放射科医生的诊断性能,可能作为有价值的诊断工具。

研究设计与样本

  • 研究纳入2020年1月至2022年12月经组织病理学证实的262个ABUS检出乳腺病灶(231名女性,平均年龄52.2岁;145个恶性、117个良性),由两位放射科医生判读BI-RADS分类,并以AI-CAD结果按四种方式调整BI-RADS分类,比较AI辅助诊断与放射科医生的诊断性能。

关键影像表现/征象

  • AI-CAD阴性癌症较AI-CAD阳性癌症更小、较少出现回缩现象、BI-RADS分类更低。
  • 在非肿块型病灶中,AI-CAD阴性癌症无后方声影。

诊断标准与关键数值

  • 放射科医生诊断的AUC为0.870(95%CI 0.832-0.908)。
  • AI-aided 1(放射科医生使用AI结果修改BI-RADS分类)的AUC为0.919(95%CI 0.890-0.947),较放射科医生显著提高(P=0.001)。
  • AI-aided 2(根据AI结果上调或下调BI-RADS分类)的AUC为0.884(95%CI 0.844-0.923),提高无统计学显著性。
  • AI-aided 3(仅对AI阳性结果上调BI-RADS分类)的AUC为0.890(95%CI 0.852-0.929),提高无统计学显著性。
  • AI-aided 4(仅对AI阴性结果下调BI-RADS分类)的AUC为0.890(95%CI 0.853-0.928),提高无统计学显著性。

临床应用与阅片要点

  • AI-CAD结果可用于直接辅助修改BI-RADS分类,可能提高诊断性能。
  • AI-CAD阴性病灶仍需注意其可能为较小、无回缩现象、BI-RADS分类较低或非肿块型无后方声影的癌症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aimed to evaluate the diagnostic performance of radiologists following the utilization of artificial intelligence (AI)-based computer-aided detection software (CAD) in detecting suspicious lesions in automated breast ultrasounds (ABUS).

MATERIALS AND METHODS: ABUS-detected 262 breast lesions (histopathological verification; January 2020 to December 2022) were included. Two radiologists reviewed the images and assigned a Breast Imaging Reporting and Data System (BI-RADS) category. ABUS images were classified as positive or negative using AI-CAD. The BI-RADS category was readjusted in four ways: the radiologists modified the BI-RADS category using the AI results (AI-aided 1), upgraded or downgraded based on AI results (AI-aided 2), only upgraded for positive results (AI-aided 3), or only downgraded for negative results (AI-aided 4). The AI-aided diagnostic performances were compared to radiologists. The AI-CAD-positive and AI-CAD-negative cancer characteristics were compared.

RESULTS: For 262 lesions (145 malignant and 117 benign) in 231 women (mean age, 52.2 years), the area under the receiver operator characteristic curve (AUC) of radiologists was 0.870 (95% confidence interval [CI], 0.832-0.908). The AUC significantly improved to 0.919 (95% CI, 0.890-0.947; P = 0.001) using AI-aided 1, whereas it improved without significance to 0.884 (95% CI, 0.844-0.923), 0.890 (95% CI, 0.852-0.929), and 0.890 (95% CI, 0.853-0.928) using AI-aided 2, 3, and 4, respectively. AI-CAD-negative cancers were smaller, less frequently exhibited retraction phenomenon, and had lower BI-RADS category. Among nonmass lesions, AI-CAD-negative cancers showed no posterior shadowing.

CONCLUSION: AI-CAD implementation significantly improved the radiologists' diagnostic performance and may serve as a valuable diagnostic tool.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Kwon MR, Youn I, Lee MY, et al. Diagnostic Performance of Artificial Intelligence-Based Computer-Aided Detection Software for Automated Breast Ultrasound. Acad Radiol. 2023. PMID: 37813703. doi:10.1016/j.acra.2023.09.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。