对比增强乳腺X线摄影的伪影与陷阱:避免误读的技巧与策略
本文讨论对比增强乳腺X线摄影(CEM)的图像解读,重点阐述图像采集过程中出现的CEM特异性伪影和对比剂相关伪影,以及因技术因素和诊断困难导致的陷阱,包括乳腺盲区、背景实质强化、低强化病灶和良性强化病变,旨在帮助避免误读。
要点
- CEM伪影包括CEM特异性和对比剂相关伪影,需与病理表现区分。
- 乳腺盲区(腋窝、内侧、近胸壁)可能不在成像野内,是CEM相对MRI的劣势。
- 背景实质强化可影响CEM解读性能。
核心结论
- CEM解读需仔细评估技术、伪影和陷阱,使用标准词典分类并给出适当随访建议,以避免将伪影和陷阱误判为病理情况。
研究设计与样本
- 本文为综述,讨论CEM图像解读,聚焦可能遇到的伪影和陷阱,信息来源为作者经验与文献综述,未报告系统检索范围或纳入文献数量。
临床应用与阅片要点
- 作者强调CEM阅片时应识别并区分伪影与病理表现,注意乳腺盲区、背景实质强化、低强化病灶及良性强化病变等可能影响判读的因素。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Contrast-enhanced mammography (CEM) involves addition of intravenous iodinated contrast material at digital mammography, thus increasing the ability to detect breast cancer owing to tumor contrast enhancement. After image acquisition, interpretation includes careful assessment of the technique, artifacts, and pitfalls and reporting with a standard lexicon category and appropriate follow-up recommendations. Artifacts and pitfalls that may cause image misinterpretation should be detected and distinguished from pathologic conditions. Different artifacts apparent on CEM images are usually caused during image acquisition and include CEM-specific and contrast agent-related artifacts, apart from the typical digital mammography artifacts. The pitfalls are related to technical and diagnostic difficulties. One disadvantage of CEM that MRI does not have is a technical factor related to a mammography technique that consists of blind spots that may not be included in the imaging field of mammography views, including the axilla, medial region of the breast, or areas close to the breast wall. Normal breast tissue enhancement called background parenchymal enhancement is also present at CEM and may affect interpretation performance. Diagnostic pitfalls are caused by minimally enhancing lesions, such as invasive lobular carcinomas and mucinous carcinomas, which are difficult to detect with CEM, resulting in false-negative findings. Benign lesions can show enhancement at CEM and represent false-positive lesions that should also be recognized. The authors discuss image interpretation of CEM studies and focus on the artifacts and pitfalls that may be encountered. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.
引用
- Lorente-Ramos RM, Azpeitia-Armán J, Oliva-Fonte C, et al. Contrast-enhanced Mammography Artifacts and Pitfalls: Tips and Tricks to Avoid Misinterpretation. Radiographics. 2023. PMID: 37792595. doi:10.1148/rg.230021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。