新型软件对子宫二维超声图像进行三维表面重建在子宫肌瘤定位中的准确性
研究纳入2019至2021年因症状性肌瘤行子宫切除术的35-55岁女性,用FMRA软件将二维经阴道超声图像后处理为三维渲染子宫模型,与病理大体评估比较肌瘤大小和位置。25例女性各取最大一枚肌瘤(共25枚),大小(L1 R²=0.9723、L2 R²=0.9784)和位置(X R²=0.9618、Y R²=0.9753)均相关性良好;两名超声医师测量三维模型L1、L2、L3的Cronbach's α=0.9,可重复性好。作者认为FMRA是定位肌瘤的新工具,其准确性有助于手术规划和引导操作。
要点
- FMRA将二维经阴道超声图像后处理为三维渲染子宫模型,用于肌瘤定位。
- 与子宫切除标本病理评估比较,肌瘤大小L1 R²=0.9723、L2 R²=0.9784。
- 肌瘤位置X R²=0.9618、Y R²=0.9753,相关性良好。
核心结论
- FMRA软件对二维超声图像行三维表面重建定位子宫肌瘤,与病理评估相比大小和位置相关性良好,作者认为其准确性有助于手术规划和引导操作。
研究设计与样本
- 前瞻性纳入2019至2021年一家三级医院因症状性肌瘤计划行子宫切除术的35-55岁女性,经阴道超声按预设指南采集二维图像和视频,经USB导入FMRA软件后处理生成三维渲染子宫模型,由经验丰富的病理医师按设定方案对子宫切除标本行大体评估;共分析25例女性各一枚最大肌瘤(25枚)。
诊断标准与关键数值
- 以病理大体评估为参照,三维模型与病理评估的肌瘤大小相关性L1 R²=0.9723、L2 R²=0.9784,位置相关性X R²=0.9618、Y R²=0.9753;两名超声医师对三维模型肌瘤L1、L2、L3尺寸测量的Cronbach's α=0.9。
临床应用与阅片要点
- 作者认为FMRA准确性经证实,有助于子宫肌瘤手术规划和引导操作。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Three-dimensional surface rendering of 2-D ultrasound images of the uterus in mapping uterine fibroids is a fast-evolving imaging technique that holds great potential for gynecology. The purpose of this study was to assess the accuracy of 3-D surface rendering of 2-D ultrasound images of the uterus using a new Fibroid Mapping Reviewer Application (FMRA) software for mapping uterine fibroids as compared with the pathological evaluation of uterine fibroids in pre-menopausal women undergoing hysterectomy.
METHODS: We enrolled women aged 35-55 y scheduled for hysterectomy for symptomatic fibroids at a tertiary care hospital from 2019 to 2021. Per pre-set guidelines, we recorded 2-D images and videos of the uterus with fibroids during the transvaginal ultrasound. The recordings were transferred through USB, loaded in the FMRA software and post-processed to generate a 3-D rendered uterus model. An experienced pathologist assessed and documented the gross examination details per a set protocol. We compared the pre-specified dimensions related to the size (L1, L2) and location (X, Y) of fibroids between the 3-D model and the pathologist's assessment of the hysterectomy specimen.
RESULTS: A total of 25 fibroids in 25 women, the single largest per woman, were considered for analysis. The two methods had good correlation with respect to size (for L1, R² = 0.9723, and for L2, R² = 0.9784) and location (for X, R² = 0.9618, and for Y, R² = 0.9753). Inter-observer analysis revealed that measurements from two sonologists were reproducible (Cronbach's α = 0.9 for the L1, L2 and L3 dimensions of fibroids from the 3-D model).
CONCLUSION: The FMRA is a novel tool for mapping fibroids. With its proven accuracy, it will be helpful in planning surgeries and during guided procedures for managing uterine fibroids.
引用
- Guruvare S, Hebbar S, Bai L, et al. Accuracy of 3-D Surface Rendering of 2-D Ultrasound Images of the Uterus Using a Novel Software in Mapping Uterine Fibroids. Ultrasound Med Biol. 2023. PMID: 37821244. doi:10.1016/j.ultrasmedbio.2023.09.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。