超声剪切波弹性成像测量肾皮质弹性在儿童肾小球疾病中的诊断效能
本研究纳入71例经肾活检确诊的肾小球疾病患儿和60名健康志愿者,采用剪切波弹性成像测量肾皮质杨氏模量。疾病组各部位杨氏模量均显著高于对照组(P<0.001),左肾中极杨氏模量诊断效能最佳(AUC 0.936),临界值15.48 kPa,敏感度87.3%、特异度86.7%。不同病理类型及病理分级间杨氏模量无显著差异(P>0.05)。
要点
- 左肾中极杨氏模量诊断儿童肾小球疾病AUC 0.936,临界值15.48 kPa。
- 疾病组各肾极及双侧杨氏模量均高于对照组(P<0.001)。
- 杨氏模量在病理类型及Lee、Oxford、ISKDC分级间无显著差异(P>0.05)。
核心结论
- 剪切波弹性成像技术是诊断儿童肾小球疾病的一种无创、可行的方法;但本研究中该技术在区分不同病理类型和疾病分级方面未显示出良好效能。
研究设计与样本
- 研究纳入71例经肾活检确诊的肾小球疾病患儿和60名健康志愿者,对所有个体双肾行常规超声及剪切波弹性成像检查。
关键影像表现/征象
- 测量肾长度、肾宽度、肾厚度、肾实质厚度、叶间动脉阻力指数及中极和下极杨氏模量;疾病组杨氏模量显著高于对照组(P<0.001)。
诊断标准与关键数值
- 左肾中极杨氏模量AUC 0.936(P<0.001),临界值15.48 kPa,敏感度87.3%,特异度86.7%。
临床应用与阅片要点
- 作者认为剪切波弹性成像技术是诊断儿童肾小球疾病的无创、可行方法,但本研究中该技术在区分不同病理类型和疾病分级方面未显示良好效能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the diagnostic performance of renal cortical elasticity expressed by Young's modulus (YM) using the supersonic shear wave imaging (SSI) technique in pediatric glomerular disease.
MATERIALS AND METHODS: Seventy-one children with glomerular disease confirmed by renal biopsy and sixty healthy volunteers were enrolled in this study. Conventional and SSI ultrasound examinations were performed in all individuals for both kidneys. We measured renal length, renal width, renal thickness, parenchyma thickness, interlobar arterial resistive index (RI) and the YM of the middle and lower pole.
RESULTS: Regardless of which pole and which side of the kidney, the YM in the disease group was significantly higher than that in the control group (P < 0.001). The YM of the middle pole in the left kidney demonstrated the largest AUC (0.936, P < 0.001), and the corresponding cut-off value was 15.48 kPa with a sensitivity of 87.3% and a specificity of 86.7%. There was no significant difference in the YM among different pathological types of pediatric glomerular disease in the disease group, and the same in different grades of patients with Immunoglobulin A (IgA) nephropathy by Lee classification and the Oxford Classification as well as Henoch-Schonlein purpura nephritis (HSPN) by International Study of Kidney Disease in Children (ISKDC) classification (P > 0.05). We found positive but weak correlations between the YM and renal length (r = 0.299, P = 0.001), renal width (r = 0.408, P < 0.001), renal thickness (r = 0.299, P = 0.001), and parenchyma thickness (r = 0.212, P = 0.015), whereas the YM had no significant correlations with age, sex, BMI, interlobar arterial RI, and laboratory findings (P > 0.05).
CONCLUSIONS: SSI technology is a non-invasive and feasible method for the diagnosis of pediatric glomerular disease. However, SSI did not show good performance in distinguishing different pathological types and disease grades in our study.
引用
- Shi LQ, Sun J, Yuan L, et al. Diagnostic performance of renal cortical elasticity by supersonic shear wave imaging in pediatric glomerular disease. Eur J Radiol. 2023. PMID: 37820521. doi:10.1016/j.ejrad.2023.111113
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。