健康成人胰腺二维剪切波弹性成像的可行性及测量价值:评估、影响因素、参考范围、测量稳定性与可重复性
2022年前瞻性纳入387名健康成人,评估胰腺二维剪切波弹性成像的成功率、测量值、影响因素、参考范围及操作者内稳定性和操作者间可重复性。胰腺体部成功率最高(89.6%),尾部最低(72.8%);性别和BMI是三个部位测量成功率的独立影响因素;操作者内稳定性极好,操作者间可重复性差至良好。
要点
- 健康成人胰腺二维剪切波弹性成像体部成功率最高(89.6%),尾部最低(72.8%)。
- 性别和BMI是胰腺三个部位测量成功率的独立影响因素。
- 同一受试者胰腺三个部位的Emean值不相同。
核心结论
- 胰腺二维剪切波弹性成像可用于评估健康成人胰腺硬度,但其成功率和测量值受多种因素影响。
研究设计与样本
- 前瞻性研究,2022年纳入387名健康成人,采用逻辑回归和线性回归分析影响因素,计算组内相关系数评估操作者内稳定性和操作者间可重复性。
诊断标准与关键数值
- 胰腺体部二维剪切波弹性成像成功率89.6%,尾部成功率72.8%。
- 性别和BMI是胰腺三个部位测量成功率的独立影响因素。
- BMI和图像深度是胰腺体部Emean的独立影响因素;感兴趣区深度和BMI分别是胰头和胰尾Emean的独立影响因素。
- 操作者内稳定性极好,操作者间可重复性差至良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The present study was aimed at assessing the success rate and measurement value, determining the influencing factors and reference range and examining the intra-operator stability and inter-operator reproducibility of pancreatic 2-D shear wave elastography (SWE) measurement in healthy adults.
METHODS: In 2022, 387 healthy adults were prospectively recruited. Logistic regression and linear regression analyses were used to explore the factors influencing the success rate and the measurement value of pancreatic 2-D SWE measurement, respectively. A two-sided 95% reference range was estimated accordingly. The intraclass correlation coefficient was calculated to evaluate the intra-operator stability and inter-operator reproducibility of the pancreatic 2-D SWE measurement.
RESULTS: The pancreatic body (89.6%) bore the highest while the tail (72.8%) bore the lowest success rate of pancreatic 2-D SWE measurement. Sex and body mass index (BMI) were the independent factors influencing measurement success rate in all three parts of the pancreas. Mean measurement values (Emean) were not the same in the three parts of the pancreas of the same participant. BMI and image depth were the independent factors influencing Emean in the pancreatic body, while region of interest depth and BMI were the only independent factors influencing Emean in the pancreatic head and tail, respectively. The intra-operator stability of pancreatic 2-D SWE measurement was found to be excellent, whereas its inter-operator reproducibility was poor to good.
CONCLUSION: Pancreatic 2-D SWE is a reliable technique for evaluating pancreatic stiffness in healthy adults, but its success rate and measurement value are influenced by multiple factors.
引用
- Huang J, Peng J, Long H, et al. Feasibility and Measurement Value of Pancreatic 2-D Shear Wave Elastography in Healthy Adults: Evaluation, Influencing Factors, Reference Range, Measurement Stability and Reproducibility. Ultrasound Med Biol. 2023. PMID: 37880058. doi:10.1016/j.ultrasmedbio.2023.09.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。