使用倾斜激发平面的空间定制二维射频脉冲的改良小视野扩散加权MRI对胰腺癌图像质量的影响:与传统全视野成像的比较
回顾性纳入21例病理确诊胰腺导管腺癌患者,在3T系统上比较倾斜激发平面小视野DWI(tilted r-DWI)与传统全视野DWI(f-DWI)的图像质量与ADC值;tilted r-DWI除混叠伪影外各项主观评分及CNR、SIR均显著更高,SNR显著更低,ADC值无显著差异。
要点
- tilted r-DWI除混叠伪影外各项图像质量评分均显著高于f-DWI(p<0.01)。
- tilted r-DWI的胰腺癌CNR与SIR显著高于f-DWI,但SNR显著低于f-DWI。
- 两种方法测得的胰腺癌平均ADC值无显著差异(p=0.11)。
核心结论
- 在胰腺导管腺癌的MRI评估中,采用倾斜激发平面二维射频技术的r-DWI较f-DWI显著改善图像质量、提高CNR并减少图像伪影,且不显著影响ADC值。
研究设计与样本
- 回顾性研究纳入21例病理确诊胰腺导管腺癌患者(平均70.7岁,范围50-85岁),所有MR图像均使用3T系统采集,由两名放射科医师进行主观评分并以感兴趣区测量定量指标。
关键影像表现/征象
- tilted r-DWI除混叠伪影外,模糊或鬼影伪影、磁敏感伪影、胰腺解剖结构显示、层间信号均匀性、整体图像质量及胰腺癌病灶显著性评分均显著高于f-DWI(p<0.01)。
- 胰腺癌CNR在tilted r-DWI为6.7±4.4,f-DWI为4.7±3.9,tilted r-DWI显著更高(p<0.01)。
- 胰腺癌SIR在tilted r-DWI为2.02±0.72,f-DWI为1.72±0.60,tilted r-DWI显著更高(p<0.01)。
- 胰腺癌SNR在tilted r-DWI为56.0±33.1,f-DWI为113.6±67.3,tilted r-DWI显著更低(p<0.01)。
诊断标准与关键数值
- 胰腺癌平均ADC值:tilted r-DWI为1225±250,f-DWI为1294±302,两者无显著差异(p=0.11)。
临床应用与阅片要点
- 阅片时可利用tilted r-DWI除混叠伪影外各主观评分及CNR、SIR更优的特点评估胰腺癌病灶。
- 需注意tilted r-DWI的SNR显著低于f-DWI(56.0±33.1 vs. 113.6±67.3,p<0.01)。
- tilted r-DWI与f-DWI测得的胰腺癌平均ADC值无显著差异(p=0.11)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Modified reduced FOV diffusion-weighted imaging (DWI) using spatially-tailored 2D RF pulses with tilted excitation plane (tilted r-DWI) has been developed. The purpose of this study was to evaluate the impact on image quality and quantitative apparent diffusion coefficient (ADC) values of tilted r-DWI for pancreatic ductal adenocarcinomas (PDAC) in comparison to conventional full-FOV DWI (f-DWI).
METHODS: This retrospective study included 21 patients (mean 70.7, range 50-85 years old) with pathologically confirmed PDAC. All MR images were obtained using 3 T systems. Two radiologists evaluated presence of blurring or ghost artifacts, susceptibility artifacts, and aliasing artifacts; anatomic visualization of the pancreas; interslice signal homogeneity; overall image quality; and conspicuity of the PDAC. For quantitative analysis, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), signal-intensity ratio (SIR) and ADC values were measured using regions of interest.
RESULTS: All image quality scores except aliasing artifacts in tilted r-DWI were significantly higher than those in f-DWI (p < 0.01). The CNR and SIR of PDAC were significantly higher in tilted r-DWI than in f-DWI (6.7 ± 4.4 vs. 4.7 ± 3.9, 2.02 ± 0.72 vs. 1.72 ± 0.60, p < 0.01). Conversely, the SNR of PDAC in tilted r-DWI was significantly lower than that in f-DWI (56.0 ± 33.1 vs. 113.6 ± 67.3, p < 0.01). No significant difference was observed between mean ADC values of the PDAC calculated from tilted r-DWI (tilted r-ADC) and those from f-DWI (f-ADC) (1225 ± 250 vs. 1294 ± 302, p = 0.11).
CONCLUSION: The r-DWI using 2D RF techniques with a tilted excitation plane was shown to significantly improve the image quality and CNR and reduce image artifacts compared to f-DWI techniques in MRI evaluations of PDAC without significantly affecting ADC values.
引用
- Tanabe M, Hideura K, Higashi M, et al. Impact on the image quality of modified reduced field-of-view diffusion-weighted magnetic resonance imaging of pancreatic adenocarcinoma using spatially tailored two-dimensional radiofrequency pulses with a tilted excitation plane: A comparison with conventional field-of-view imaging. Eur J Radiol. 2023. PMID: 37832196. doi:10.1016/j.ejrad.2023.111138