文献速递腹部技术与安全CT

光子计数CT小肠造影碘密度评估克罗恩病炎症严重程度:与内镜组织病理学比较

Crohn's disease inflammation severity assessment with iodine density from photon counting CT enterography: comparison with endoscopic histopathology.
PubMed 文献 · Abdom Radiol (NY) · 2023-10-09

回顾性纳入23例克罗恩病患者,行光子计数CT小肠造影碘密度分析并与内镜/手术病理对照。活动性炎症最佳碘密度阈值为2.7 mg/mL,敏感度97%、特异度100%、准确率98%(AUC=1.00);区分轻度与中重度炎症最佳阈值为3.4 mg/mL,敏感度83%、特异度89%、准确率87%(AUC=0.85)。

要点

  • 回肠壁碘密度2.7 mg/mL可区分活动性炎症,敏感度97%、特异度100%、准确率98%。
  • 碘密度3.4 mg/mL可区分轻度与中重度炎症,敏感度83%、特异度89%(AUC=0.85)。
  • 读者间ICC为0.94,读者内ICC为0.81/0.86,测量可重复性较好。

核心结论

  • 光子计数CT小肠造影的碘密度可区分轻度与中重度活动性炎症。

研究设计与样本

  • 回顾性研究,23例克罗恩病患者(15例女性,平均年龄52岁,SD 17),行光子计数CT小肠造影,由两名腹部放射科医生在SyngoVia上于末端或新末端回肠壁最明显受累区各画两个感兴趣区,参考标准为内镜/手术病理。

关键影像表现/征象

  • 于末端或新末端回肠壁肉眼最受累区域测量碘密度。
  • 15/23例有活动性炎症:9/15轻度、4/15中度、2/15重度。

诊断标准与关键数值

  • 活动性炎症最佳碘密度阈值2.7 mg/mL,敏感度97%、特异度100%、准确率98%(AUC=1.00)。
  • 区分轻度与中重度炎症最佳碘密度阈值3.4 mg/mL,敏感度83%、特异度89%、准确率87%(AUC=0.85)。
  • 读者内信度ICC:R1为0.81,R2为0.86;读者间信度ICC为0.94。

临床应用与阅片要点

  • 作者结论认为光子计数CT小肠造影碘密度可区分轻度与中重度活动性炎症。
  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine optimal iodine density thresholds for active inflammation in CD patients with PCCT enterography and determine if iodine density can be used to stratify CD activity severity.

METHODS: A retrospective PACS search identified patients with CD imaged with PCCT enterography from 4/11/2022 to 10/30/2022 and with clinical notes, endoscopic/surgical pathology and available source PCCT data for iodine density analysis. Two abdominal radiologists with expertise in CD each drew two region of interest measurements within the visibly most affected region of terminal or neoterminal ileum wall on commercially available system (SyngoVia). Radiologists were blinded to clinical information and pathologic findings. Disease activity and severity were recorded from the pathology report. Harvey-Bradshaw Index, medications, and laboratory values were recorded. Receiver operating characteristic (ROC) curves were utilized to determine the optimum iodine density threshold for active inflammation and mild versus moderate-to-severe inflammation. Intra- and inter-reader agreement was assessed by intra-class correlation coefficient (ICC).

RESULTS: 23 CD patients (15 females; mean [SD] age: 52 [17] years) imaged with PCCT enterography were included. 15/23 had active inflammation: 9/15 mild, 4/15 moderate, and 2/15 severe active inflammation. The optimal iodine density threshold for active inflammation was 2.7 mg/mL, with 97% sensitivity, 100% specificity, and 98% accuracy (AUC = 1.00). The optimal iodine density threshold for distinguishing mild from moderate-to-severe inflammation was 3.4 mg/mL, with 83% sensitivity, 89% specificity, and 87% accuracy (AUC = 0.85). Intra-reader reliability (R1/R2) ICC was 0.81/0.86. Inter-reader reliability ICC was 0.94.

CONCLUSION: Iodine density from PCCT enterography can distinguish mild from moderate-to-severe active inflammation.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Dane B, Qian K, Soni R, et al. Crohn's disease inflammation severity assessment with iodine density from photon counting CT enterography: comparison with endoscopic histopathology. Abdom Radiol (NY). 2023. PMID: 37814149. doi:10.1007/s00261-023-04060-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。