深度学习重建在肝脏扩散加权成像中的临床可行性:图像质量改善及对表观扩散系数值的影响
这项前瞻性研究纳入85例患者170个肝脏病灶,在3.0-T MRI上对b值0、50、800 s/mm²的DWI分别行深度学习重建(DLR)与非DLR重建。DLR组定性评分、SNR、CNR及肝/实质边界锐度均高于非DLR组,DLR使恶性肿瘤ADC值降低(1.105[0.904, 1.340] vs 1.114[0.904, 1.320]),但恶性诊断价值无显著差异(P=57.3)。
要点
- DLR可提高肝脏DWI的图像质量,DWI800定性评分DLR组4.77±0.52高于非DLR组4.30±0.63(P<0.001)。
- DLR使恶性肿瘤ADC值降低(1.105[0.904, 1.340] vs 1.114[0.904, 1.320]),P<0.001。
- DLR与非DLR对恶性肿瘤的诊断价值无显著差异(P=57.3)。
核心结论
- DLR改善了肝脏DWI的图像质量,DLR降低了病灶ADC值,但在3.0-T MRI系统上未影响ADC鉴别恶性肿瘤的诊断效能。
研究设计与样本
- 前瞻性研究,纳入2022年2月至2023年2月连续肝脏病灶患者85例、170个病灶,在3 Tesla下对b值0(DWI0)、50(DWI50)、800 s/mm²(DWI800)的DWI图像行DLR与非DLR重建,并行体模实验探究决定DLR对ADC值影响的因素。
关键影像表现/征象
- DLR组定性评分高于非DLR组,DWI800时DLR组4.77±0.52 vs 非DLR组4.30±0.63(P<0.001)。
- DLR组SNR、CNR及肝/实质边界锐度均高于非DLR组。
诊断标准与关键数值
- 图像质量定性评估采用Likert评分系统。
- 定量评估采用ROI分析测量SNR、CNR及肝/实质边界锐度。
- DLR组恶性肿瘤ADC为1.105[0.904, 1.340],非DLR组为1.114[0.904, 1.320],DLR降低恶性肿瘤ADC(P<0.001)。
- DLR与非DLR鉴别恶性肿瘤的诊断价值无显著差异(P=57.3)。
临床应用与阅片要点
- 体模实验证实低分辨率图像ADC降低,且不均匀结构中ADC降低幅度大于均匀结构(P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Diffusion-weighted imaging (DWI) of the liver suffers from low resolution, noise, and artifacts. This study aimed to investigate the effect of deep learning reconstruction (DLR) on image quality and apparent diffusion coefficient (ADC) quantification of liver DWI at 3 Tesla.
METHOD: In this prospective study, images of the liver obtained at DWI with b-values of 0 (DWI0), 50 (DWI50) and 800 s/mm2 (DWI800) from consecutive patients with liver lesions from February 2022 to February 2023 were reconstructed with and without DLR (non-DLR). Image quality was assessed qualitatively using Likert scoring system and quantitatively using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and liver/parenchyma boundary sharpness from region-of-interest (ROI) analysis. ADC value of lesion were measured. Phantom experiment was also performed to investigate the factors that determine the effect of DLR on ADC value. Qualitative score, SNR, CNR, boundary sharpness, and apparent diffusion coefficients (ADCs) for DWI were compared using paired t-test and Wilcoxon signed rank test. P < 0.05 was considered statistically significant.
RESULTS: A total of 85 patients with 170 lesions were included. DLR group showed a higher qualitative score than the non-DLR group. for example, with DWI800 the score was 4.77 ± 0.52 versus 4.30 ± 0.63 (P < 0.001). DLR group also showed higher SNRs, CNRs and boundary sharpness than the non-DLR group. DLR reduced the ADC of malignant tumors (1.105[0.904, 1.340] versus 1.114[0.904, 1.320]) (P < 0.001), but there was no significant difference in the diagnostic value of malignancy for DLR and non-DLR groups (P = 57.3). The phantom study confirmed a reduction of ADC in images with low resolution, and a stronger reduction of ADC in heterogeneous structures than in homogeneous ones (P < 0.001).
CONCLUSIONS: DLR improved image quality of liver DWI. DLR reduced the ADC value of lesions, but did not affect the diagnostic performance of ADC in distinguishing malignant tumors on a 3.0-T MRI system.
引用
- Chen Q, Fang S, Yuchen Y, et al. Clinical feasibility of deep learning reconstruction in liver diffusion-weighted imaging: Improvement of image quality and impact on apparent diffusion coefficient value. Eur J Radiol. 2023. PMID: 37862927. doi:10.1016/j.ejrad.2023.111149
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。