文献速递腹部泌尿生殖MRCT

常染色体显性多囊肾病中基于三维多模态深度学习的器官体积测量重测可重复性

Test Retest Reproducibility of Organ Volume Measurements in ADPKD Using 3D Multimodality Deep Learning.
PubMed 文献 · Acad Radiol · 2023-10-03

研究利用nnU-net构建三维多模态多类分割模型,在413例受试者的T1、T2、SSFP、DWI和CT上训练验证,并对19例ADPKD患者间隔3周内两次扫描进行重测可重复性评估。结果显示五序列平均后肾脏体积重测绝对百分比差异为1.3%,优于所有五位专家观察者,且可可靠进行Mayo影像分类(AUC=100%)。

要点

  • 五序列平均后肾脏体积重测可重复性达1.3%,优于五位专家观察者。
  • 模型自动分割可可靠进行Mayo影像分类,AUC为100%。
  • 内部、外部及重测评估中Dice均大于97%,Jaccard均大于0.94。

核心结论

  • 三维深度学习可在五种MRI序列上测量器官体积,利用离群值分析和平均达到1.3%的总肾脏重测可重复性。

研究设计与样本

  • 基于nnU-net的三维多模态多类分割模型,使用413例受试者的T1、T2、SSFP、DWI和CT训练/验证;重测可重复性在19例ADPKD受试者中评估,间隔3周内扫描两次。

诊断标准与关键数值

  • 内部(n=25)、外部(n=37)及重测评估(19例受试者38次扫描)中,所有三个器官和五个序列的Dice相似系数大于97%、Jaccard指数大于0.94、平均表面距离小于1 mm、平均Hausdorff距离小于2 cm;五序列平均后肾脏重测绝对百分比差异为1.3%;Mayo影像分类AUC为100%。

临床应用与阅片要点

  • 阅片时可利用多序列自动分割和离群值分析减少体积测量变异,五序列平均测量重测可重复性为1.3%,并支持Mayo影像分类。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Following autosomal dominant polycystic kidney disease (ADPKD) progression by measuring organ volumes requires low measurement variability. The objective of this study is to reduce organ volume measurement variability on MRI of ADPKD patients by utilizing all pulse sequences to obtain multiple measurements which allows outlier analysis to find errors and averaging to reduce variability.

MATERIALS AND METHODS: In order to make measurements on multiple pulse sequences practical, a 3D multi-modality multi-class segmentation model based on nnU-net was trained/validated using T1, T2, SSFP, DWI and CT from 413 subjects. Reproducibility was assessed with test-re-test methodology on ADPKD subjects (n = 19) scanned twice within a 3-week interval correcting outliers and averaging the measurements across all sequences. Absolute percent differences in organ volumes were compared to paired students t-test.

RESULTS: Dice similarlity coefficient > 97%, Jaccard Index > 0.94, mean surface distance < 1 mm and mean Hausdorff Distance < 2 cm for all three organs and all five sequences were found on internal (n = 25), external (n = 37) and test-re-test reproducibility assessment (38 scans in 19 subjects). When averaging volumes measured from five MRI sequences, the model automatically segmented kidneys with test-re-test reproducibility (percent absolute difference between exam 1 and exam 2) of 1.3% which was better than all five expert observers. It reliably stratified ADPKD into Mayo Imaging Classification (area under the curve=100%) compared to radiologist.

CONCLUSION: 3D deep learning measures organ volumes on five MRI sequences leveraging the power of outlier analysis and averaging to achieve 1.3% total kidney test-re-test reproducibility.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. He X, Hu Z, Dev H, et al. Test Retest Reproducibility of Organ Volume Measurements in ADPKD Using 3D Multimodality Deep Learning. Acad Radiol. 2023. PMID: 37798206. doi:10.1016/j.acra.2023.09.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。