多变量定量超声参数评估肝脂肪变性
这项前瞻性多中心研究纳入582例慢性肝病患者,以MRI质子密度脂肪分数(PDFF)定义的至少5%脂肪变性为参考标准,评估不同定量超声参数组合模型的诊断性能。结果显示,联合使用UGAP、IBSC和SNR的模型4诊断效能最高,AUC为0.96,模型3和模型4对至少5%脂肪变性的判别能力优于其他模型(P < .01)。
要点
- 联合UGAP、IBSC和SNR的模型4诊断至少5%脂肪变性的AUC最高,达0.96。
- 模型1(仅UGAP)、模型2(UGAP+IBSC)、模型3(UGAP+SNR)的AUC分别为0.92、0.93、0.95。
- 模型3和模型4对至少5%脂肪变性的判别能力优于其他模型(P < .01)。
核心结论
- 基于定量超声参数UGAP、IBSC和SNR构建的模型能准确判别慢性肝病患者是否存在至少5%的脂肪变性。
研究设计与样本
- 前瞻性多中心研究,纳入2020年2月至2021年4月间582例慢性肝病患者,以MRI PDFF定义的至少5%脂肪变性为参考标准,采用1000次bootstrap样本进行内部验证。
诊断标准与关键数值
- 模型1(仅UGAP)诊断至少5%脂肪变性的AUC为0.92,模型2(UGAP+IBSC)为0.93,模型3(UGAP+SNR)为0.95,模型4(UGAP+IBSC+SNR)为0.96;bootstrap校正后C-index分别为0.92、0.93、0.95、0.96。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Because of the global increase in the incidence of nonalcoholic fatty liver disease, the development of noninvasive, widely available, and highly accurate methods for assessing hepatic steatosis is necessary. Purpose To evaluate the performance of models with different combinations of quantitative US parameters for their ability to predict at least 5% steatosis in patients with chronic liver disease (CLD) as defined using MRI proton density fat fraction (PDFF). Materials and Methods Patients with CLD were enrolled in this prospective multicenter study between February 2020 and April 2021. Integrated backscatter coefficient (IBSC), signal-to-noise ratio (SNR), and US-guided attenuation parameter (UGAP) were measured in all participants. Participant MRI PDFF value was used to define at least 5% steatosis. Four models based on different combinations of US parameters were created: model 1 (UGAP alone), model 2 (UGAP with IBSC), model 3 (UGAP with SNR), and model 4 (UGAP with IBSC and SNR). Diagnostic performance of all models was assessed using area under the receiver operating characteristic curve (AUC). The model was internally validated using 1000 bootstrap samples. Results A total of 582 participants were included in this study (median age, 64 years; IQR, 52-72 years; 274 female participants). There were 364 participants in the steatosis group and 218 in the nonsteatosis group. The AUC values for steatosis diagnosis in models 1-4 were 0.92, 0.93, 0.95, and 0.96, respectively. The C-indexes of models adjusted by the bootstrap method were 0.92, 0.93, 0.95, and 0.96, respectively. Compared with other models, models 3 and 4 demonstrated improved discrimination of at least 5% steatosis (P < .01). Conclusion A model built using the quantitative US parameters UGAP, IBSC, and SNR could accurately discriminate at least 5% steatosis in patients with CLD. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Han in this issue.
引用
- Kuroda H, Oguri T, Kamiyama N, et al. Multivariable Quantitative US Parameters for Assessing Hepatic Steatosis. Radiology. 2023. PMID: 37787670. doi:10.1148/radiol.230341
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。