自动筛查Dixon技术定量活体肝移植供者肝脂肪变性的有效性
本回顾性研究纳入285例活体肝移植供者候选者,于2014年1月至2019年2月同期行自动筛查Dixon(e-DIXON)技术与单 voxel 磁共振波谱(MRS)检查,以MRS为参考标准评估肝脂肪变性和铁沉积。e-DIXON诊断肝脂肪变的敏感度94%、特异度70%、阳性预测值64%、阴性预测值96%,与MRS脂肪测量强相关(r2=0.92,p<0.001);作者结论认为e-DIXON可可靠筛查肝脂肪变,但检测肝铁沉积可能不准确。
要点
- e-DIXON筛查肝脂肪变敏感度94%、特异度70%,阴性预测值96%,适合排除脂肪变。
- e-DIXON与MRS脂肪测量强相关(r2=0.92,p<0.001)。
- e-DIXON检测肝铁沉积可能不准确,铁沉积组与正常组R2值无显著差异(p=0.11)。
核心结论
- e-DIXON技术可可靠筛查肝脂肪变,但检测肝铁沉积可能不准确。
研究设计与样本
- 回顾性研究,纳入285例活体肝移植供者候选者,于2014年1月至2019年2月行e-DIXON技术和单 voxel MRS检查,以MRS为参考标准。
关键影像表现/征象
- e-DIXON诊断正常133例(47%)、脂肪124例(44%)、铁1例(0.4%)、脂肪合并铁27例(10%)。
- MRS平均脂肪信号分数在脂肪变组与正常组间差异显著(p<0.001)。
- R2值在铁沉积组与正常组间无显著差异(p=0.11)。
诊断标准与关键数值
- e-DIXON诊断肝脂肪变的敏感度94%、特异度70%、阳性预测值64%、阴性预测值96%。
- e-DIXON与MRS脂肪测量强相关(r2=0.92,p<0.001)。
临床应用与阅片要点
- e-DIXON可可靠筛查活体肝移植供者的肝脂肪变。
- e-DIXON检测肝铁沉积可能不准确。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This retrospective study aimed to evaluate the validity of an automated screening Dixon (e-DIXON) technique for quantifying hepatic steatosis in living liver-donor patients by comparison with magnetic resonance spectroscopy (MRS) as a reference standard.
METHODS: A total of 285 living liver-donor candidates were examined with the e-DIXON technique and single-voxel MRS to assess hepatic steatosis and iron deposition between January 2014 and February 2019. The sensitivity, specificity, and positive and negative predictive values (PPV and NPV) of the e-DIXON technique for hepatic steatosis were calculated. The mean fat signal fractions obtained in MRS were compared between the donors diagnosed with hepatic steatosis and the normal group. The mean R2 values of donors with or without hepatic siderosis also were compared.
RESULTS: The e-DIXON technique diagnosed normal in 133 (47%), fat in 124 (44%), iron in one (0.4%), and a combination of both fat and iron in 27 (10%) donors. The sensitivity, specificity, PPV, and NPV for diagnosing hepatic steatosis were 94%, 70%, 64%, and 96%, respectively. There was a significant difference in the mean fat signal fraction obtained in MRS between the steatosis and normal groups (p < 0.001), but R2 values were not significantly different between siderosis and normal groups (p = 0.11). The e-DIXON technique showed a strong correlation with MRS in fat measurement (r2 = 0.92, p < 0.001).
CONCLUSION: The e-DIXON technique reliably screens for hepatic steatosis but may not accurate for detecting hepatic iron deposition.
引用
- Song S, Kim H, Choi JI, et al. Validity of an automated screening Dixon technique for quantifying hepatic steatosis in living liver donors. Abdom Radiol (NY). 2023. PMID: 37801142. doi:10.1007/s00261-023-04009-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。