肝转移瘤检出与定性准确性:双能CT与单能CT结合深度学习重建的对比
前瞻性研究纳入30例结直肠癌肝转移患者,在同次屏气下分别行SECT(120 kVp)与DECT(70 keV)门静脉期腹部CT,均使用深度学习图像重建(DLIR)。在等效辐射剂量与图像噪声下,DECT与SECT的主观图像质量和病灶检出性能无显著差异,但DECT能谱HU曲线可改善不确定病灶的定性。
要点
- 在等效辐射剂量(CTDIvol 34 mGy)与图像噪声下,DECT(70 keV)与SECT的病灶检出率无显著差异(140/141,99.3%)。
- DECT需更高强度DLIR才能获得与SECT DLIRmed等效的图像噪声(HU SD 10±3 vs 10±2,P=1)。
- 对不确定病灶使用DECT能谱HU曲线可带来34次正确定性改变且无误判。
核心结论
- 在等效辐射剂量和图像噪声下,DECT(70 keV)与SECT的主观图像质量和观察者病灶性能无显著差异,但DECT能谱HU曲线可改善不确定病灶的定性。
研究设计与样本
- 前瞻性、符合《健康保险流通与责任法案》的研究,2022年3月至8月纳入30例经活检证实的结直肠癌肝转移成人患者(平均年龄58岁±11,21名男性),在同次屏气下使用DLIR行SECT(120 kVp)和DECT(70 keV)门静脉期腹部CT(Revolution CT ES;GE Healthcare)。
关键影像表现/征象
- 共识别141个病灶(124个转移瘤,17个良性),平均大小0.8 cm±0.3 cm。
- DECT与SECT的图像噪声等效:DECT DLIRhigh的HU SD为10±3,SECT DLIRmed的HU SD为10±2(P=1)。
- DECT与SECT的病灶检出率无显著差异:均为140/141(99.3%;95%CI:96.1%,100%)。
- 三位阅片者对SECT的平均病灶置信度评分分别为4.2±1.3、3.9±1.0、4.8±0.8,对DECT分别为4.1±1.4、4.0±1.0、4.7±0.8(OR 0.83;95%CI:0.62,1.11;P=0.21)。
- 小病灶(≤5mm)在SECT和DECT上的定性准确率分别为89.1%(95%CI:76.4%,96.4%;41/46)和84.8%(95%CI:71.1%,93.7%;39/46)(P=0.41)。
诊断标准与关键数值
- 图像质量高评分(4或5分):DECT为71/90(三位阅片者总评分),SECT为62/90(OR 2.01;95%CI:0.89,4.57;P=0.093),无显著差异。
- 小病灶(≤5mm)定性准确率:SECT 89.1%(95%CI:76.4%,96.4%;41/46) vs DECT 84.8%(95%CI:71.1%,93.7%;39/46),P=0.41。
- 使用能谱HU曲线对不确定病灶进行定性,共产生34次正确改变且无误判。
临床应用与阅片要点
- 在等效辐射剂量和图像噪声条件下,DECT(70 keV)与SECT对肝转移瘤的检出和定性性能无显著差异。
- DECT需要更高强度的DLIR才能达到与SECT DLIRmed等效的图像噪声。
- 对判读为不确定的病灶,可参考DECT能谱HU曲线以改善定性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess whether image quality differences between SECT (single-energy CT) and DECT (dual-energy CT 70 keV) with equivalent radiation doses result in altered detection and characterization accuracy of liver metastases when using deep learning image reconstruction (DLIR), and whether DECT spectral curve usage improves accuracy of indeterminate lesion characterization.
METHODS: In this prospective Health Insurance Portability and Accountability Act-compliant study (March through August 2022), adult men and non-pregnant adult women with biopsy-proven colorectal cancer and liver metastases underwent SECT (120 kVp) and a DECT (70 keV) portovenous abdominal CT scan using DLIR in the same breath-hold (Revolution CT ES; GE Healthcare). Participants were excluded if consent could not be obtained, if there were nonequivalent radiation doses between the two scans, or if the examination was cancelled/rescheduled. Three radiologists independently performed lesion detection and characterization during two separate sessions (SECT DLIRmedium and DECT DLIRhigh) as well as reported lesion confidence and overall image quality. Hounsfield units were measured. Spectral HU curves were provided for any lesions rated as indeterminate. McNemar's test was used to test the marginal homogeneity in terms of diagnostic sensitivity, accuracy and lesion detection. A generalized estimating equation method was used for categorical outcomes.
RESULTS: 30 participants (mean age, 58 years ± 11, 21 men) were evaluated. Mean CTDIvol was 34 mGy for both scans. 141 lesions (124 metastases, 17 benign) with a mean size of 0.8 cm ± 0.3 cm were identified. High scores for image quality (scores of 4 or 5) were not significantly different between DECT (N = 71 out of 90 total scores from the three readers) and SECT (N = 62) (OR, 2.01; 95% CI:0.89, 4.57; P = 0.093). Equivalent image noise to SECT DLIRmed (HU SD 10 ± 2) was obtained with DECT DLIRhigh (HU SD 10 ± 3) (P = 1). There was no significant difference in lesion detection between DECT and SECT (140/141 lesions) (99.3%; 95% CI:96.1%, 100%).The mean lesion confidence scores by each reader were 4.2 ± 1.3, 3.9 ± 1.0, and 4.8 ± 0.8 for SECT and 4.1 ± 1.4, 4.0 ± 1.0, and 4.7 ± 0.8 for DECT (odds ratio [OR], 0.83; 95% CI: 0.62, 1.11; P = 0.21). Small lesion (≤5mm) characterization accuracy on SECT and DECT was 89.1% (95% CI:76.4%, 96.4%; 41/46) and 84.8% (71.1%, 93.7%; 39/46), respectively (P = 0.41). Use of spectral HU lesion curves resulted in 34 correct changes in characterizations and no mischaracterizations.
CONCLUSION: DECT required a higher strength of DLIR to obtain equivalent noise compared to SECT DLIR. At equivalent radiation doses and image noise, there was no significant difference in subjective image quality or observer lesion performance between DECT (70 keV) and SECT. However, DECT spectral HU curves of indeterminate lesions improved characterization.
引用
- Jensen CT, Wong VK, Wagner-Bartak NA, et al. Accuracy of liver metastasis detection and characterization: Dual-energy CT versus single-energy CT with deep learning reconstruction. Eur J Radiol. 2023. PMID: 37806195. doi:10.1016/j.ejrad.2023.111121
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。