文献速递腹部介入CTUS

经皮影像引导腹部活检术中双极射频针道电灼的可行性与安全性

Feasibility and safety of bipolar radiofrequency track cautery during percutaneous image-guided abdominal biopsy procedures.
PubMed 文献 · Abdom Radiol (NY) · 2023-10-10

回顾性研究纳入42例具有至少一项出血危险因素、接受CT或US引导腹部活检并拟行双极射频针道电灼(BRTC)的患者,技术成功率为41/42(98%),无严重不良事件(≥3级),2/41(5%)发生轻度(1级)出血事件,未引起症状或需干预,结论认为BRTC在经皮影像引导腹部活检中可行且安全。

要点

  • 对具有出血危险因素的患者,腹部影像引导活检后使用双极射频针道电灼技术成功率达98%(41/42)。
  • 41例实施BRTC的活检中无严重不良事件(≥3级),仅2/41(5%)出现轻度(1级)出血且无需干预。
  • 1例因呼吸运动导致 introducer needle 在BRTC前从肝脏退出,致技术失败。

核心结论

  • 双极射频针道电灼在经皮影像引导腹部活检术中可行且安全。

研究设计与样本

  • 回顾性研究,纳入42例(26-79岁,女性44%)具有至少一项出血危险因素并接受腹部CT或US引导活检、拟行双极射频针道电灼(BRTC)的患者;使用18G射频电极经17G活检引导针在同轴18G空心针活检后立即插入,以温度控制方式电灼活检针道;记录出血危险因素、技术成功率和不良事件。

诊断标准与关键数值

  • 技术成功定义为完成BRTC,41/42(98%)成功;1例因呼吸运动导致引导针在BRTC前从肝脏退出而失败;不良事件分级中无严重不良事件(≥3级),轻度(1级)出血事件2/41(5%),未引起症状或需干预。

临床应用与阅片要点

  • 对于具有出血危险因素(如高风险器官包括脾或肾实质、富血供肿块、凝血酶原时间延长、肾功能不全、血小板减少、近期抗凝或未按推荐间隔停用抗凝、肝硬化、术中高血压、引导针观察至明显回血或肿瘤位于包膜下)的患者,在经皮影像引导腹部活检后使用双极射频针道电灼;注意呼吸运动可能导致引导针退出而致操作失败。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study was to assess the feasibility and safety of using a bipolar radiofrequency track cautery device during percutaneous image-guided abdominal biopsy procedures in at-risk patients.

METHODS: Forty-two patients (26-79 years old; female 44%) with at least one bleeding risk factor who underwent an abdominal image-guided (CT or US) biopsy and intended bipolar radiofrequency track cautery (BRTC) were retrospectively studied. An 18G radiofrequency electrode was inserted through a 17G biopsy introducer needle immediately following coaxial 18G core biopsy, to cauterize the biopsy track using temperature control. Bleeding risk factors, technical success, and adverse events were recorded.

RESULTS: BRTC was technically successful in 41/42 (98%) of procedures; in one patient, the introducer needle retracted from the liver due to respiratory motion prior to BRTC. BRTC following percutaneous biopsy was applied during 41 abdominal biopsy procedures (renal mass = 12, renal parenchyma = 10, liver mass = 9, liver parenchyma = 5, splenic mass or parenchyma = 4, gastrohepatic mass = 1). All patients had one or more of the following risk factors: high-risk organ (spleen or renal parenchyma), hypervascular mass, elevated prothrombin time, renal insufficiency, thrombocytopenia, recent anticoagulation or anticoagulation not withheld for recommended interval, cirrhosis, intraprocedural hypertension, brisk back bleeding observed from the introducer needle, or subcapsular tumor location. No severe adverse events (grade 3 or higher) occurred. Two (2/41, 5%) mild (grade 1) bleeding events did not cause symptoms or require intervention.

CONCLUSION: Bipolar radiofrequency track cautery was feasible and safe during percutaneous image-guided abdominal biopsy procedures. IRB approval: MBG 2022P002277.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Shyn PB, Seyal AR, Gottumukkala RV, et al. Feasibility and safety of bipolar radiofrequency track cautery during percutaneous image-guided abdominal biopsy procedures. Abdom Radiol (NY). 2023. PMID: 37816800. doi:10.1007/s00261-023-04054-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。