文献速递心血管外周血管CTDSA

新一代全心运动校正算法使收缩期主动脉瓣与冠状动脉CT诊断质量满足经导管主动脉瓣植入候选者需求

New Whole-Heart motion correction algorithm enables diagnostic CT of aortic valve and coronary arteries in systolic phase for transcatheter aortic valve implantation candidates.
PubMed 文献 · Eur J Radiol · 2023-10-06

本研究纳入64例经导管主动脉瓣植入(TAVI)候选者,行TAVI规划CT,在20%、30%、40%和75% R-R心动相位分别用新一代snapshot freeze(NGSSF)算法与标准(STD)算法重建,比较主动脉瓣测量可重复性及主动脉瓣和冠状动脉图像质量。30%相位NGSSF较STD使主动脉瓣优秀率从25.0%升至93.8%、冠状动脉可判读率从20.3%升至95.3%;以47例有创冠状动脉造影为参考,30%相位NGSSF诊断>50%冠状动脉狭窄的敏感度90%、特异度81.48%、阴性预测值91.7%、阳性预测值78.3%,STD相应为95.0%、33.33%、90.0%、51.4%。

要点

  • 30% R-R相位NGSSF重建使TAVI规划CT中主动脉瓣图像优秀率从25.0%升至93.8%。
  • 同相位NGSSF使冠状动脉可判读率从20.3%升至95.3%。
  • NGSSF诊断>50%冠状动脉狭窄敏感度90%、特异度81.48%,特异度高于STD的33.33%。

核心结论

  • 与STD算法相比,NGSSF在所有心率TAVI患者中显著改善主动脉瓣和冠状动脉图像质量;NGSSF可在同一收缩期相位实现主动脉瓣准确测量及对冠状动脉狭窄满意的诊断性能。

研究设计与样本

  • 纳入64例TAVI候选者行TAVI规划CT,冠状动脉CT血管成像扫描在20%、30%、40%和75% R-R相位分别用NGSSF与STD算法重建,比较主动脉瓣测量及其可重复性、主动脉瓣和冠状动脉图像质量;以47例(64例中)有创冠状动脉造影为参考标准,计算30%相位NGSSF与STD算法诊断冠状动脉狭窄的准确度。

诊断标准与关键数值

  • 30% R-R相位NGSSF图像主动脉瓣主观评价优秀率从STD的25.0%升至93.8%。
  • 30% R-R相位NGSSF图像冠状动脉可判读率从STD的20.3%升至95.3%。
  • 30% R-R相位NGSSF诊断>50%冠状动脉狭窄(按患者)敏感度90%、特异度81.48%、阴性预测值91.7%、阳性预测值78.3%。
  • 30% R-R相位STD诊断>50%冠状动脉狭窄(按患者)敏感度95.0%、特异度33.33%、阴性预测值90.0%、阳性预测值51.4%。

临床应用与阅片要点

  • TAVI规划CT的冠状动脉CT血管成像可在30% R-R收缩期相位用NGSSF重建,同相位完成主动脉瓣测量与冠状动脉狭窄评估。
  • NGSSF在30%相位对>50%冠状动脉狭窄的按患者特异度为81.48%,STD为33.33%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the ability of new generation snapshot freeze (NGSSF) algorithm in improving diagnostic image quality of both aortic valve and coronary arteries for transcatheter aortic valve implantation (TAVI) candidates in TAVI planning CT.

METHODS: Sixty-four TAVI candidates underwent TAVI planning CT were enrolled. Scans from coronary CT angiography were reconstructed at 20%, 30%, 40%, and 75% R-R cardiac phases with NGSSF and standard (STD) algorithm. In each phase, following parameters were compared: aortic valve measurements and their reproducibility; image quality of aortic valve and coronary arteries. The diagnostic accuracies of TAVI planning CT for coronary artery stenosis in 30% R-R phase with NGSSF and STD algorithms were calculated in 47out of 64 patients with invasive coronary angiography as reference standard.

RESULTS: For subjective image quality evaluation, the excellent rate for aortic valve improved from 25.0% to 93.8% and the interpretable rate for coronary arteries increased from 20.3% to 95.3% in the 30% phase images with NGSSF compared with images with STD. For the detection of > 50% coronary artery stenosis, the 30% phase images with NGSSF provided a sensitivity of 90%, specificity of 81.48%, negative predictive value of 91.7%, and positive predictive value of 78.3% on a per-patient basis; While images with STD, had a corresponding results of 95.0%, 33.33%, 90.0%, and 51.4%, respectively.

CONCLUSIONS: NGSSF significantly improves image quality for both aortic valve and coronary arteries compared with STD for TAVI patients of all heart rates. NGSSF enables the accurate measurement for aortic valve and satisfactory diagnostic performance for coronary arteries stenosis in the same systolic phase for TAVI planning.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Liu Z, Cheng Y, et al. New Whole-Heart motion correction algorithm enables diagnostic CT of aortic valve and coronary arteries in systolic phase for transcatheter aortic valve implantation candidates. Eur J Radiol. 2023. PMID: 37832197. doi:10.1016/j.ejrad.2023.111141

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。