文献速递外周血管心血管MR

应用MR可变形图像配准测量腹主动脉瘤应变:准确性及其与近期动脉瘤进展的关系

Measurement of Abdominal Aortic Aneurysm Strain Using MR Deformable Image Registration: Accuracy and Relationship to Recent Aneurysm Progression.
PubMed 文献 · Invest Radiol · 2023-10-19

研究通过有限元模型生成的54例合成MRI评估MR可变形图像配准测量腹主动脉瘤壁应变的准确性,并在25例有超过6个月既往监测的患者中分析MR应变与动脉瘤生长率的关系。结果显示MR应变偏倚为0.48%±0.42%,与真实应变相关系数斜率为0.963;体内腹主动脉瘤MR应变为1.2%±0.6%,低于非动脉瘤主动脉的2.4%±1.7%,且在校正最大直径后仍为生长率的独立相关因素。

要点

  • MR可变形图像配准可在标准电影MRI上准确测量腹主动脉瘤壁周向应变。
  • 腹主动脉瘤MR应变(1.2%±0.6%)低于非动脉瘤主动脉(2.4%±1.7%)。
  • 校正最大直径后,MR应变仍为腹主动脉瘤生长率的独立相关因素。

核心结论

  • 可变形图像配准分析能通过标准电影MRI准确测量腹主动脉瘤壁周向应变,并可能为腹主动脉瘤进展提供患者个体化信息。

研究设计与样本

  • 研究在54例由有限元模型模拟生成的合成MRI中评估MR应变准确性,并在25例有超过6个月既往监测的连续患者中分析MR应变与生长率的关系。

关键影像表现/征象

  • 腹主动脉瘤MR应变(1.2%±0.6%)低于非动脉瘤主动脉(2.4%±1.7%)。
  • MR应变在体内高度可重复(偏倚±95%CI为0.03%±0.31%,组内相关系数97.8%,变异系数7.14%)。

诊断标准与关键数值

  • 合成MRI中MR应变偏倚为0.48%±0.42%,与真实应变相关系数斜率为0.963。
  • MR应变与生长率相关(β=-1.563),校正最大直径后仍为独立相关因素(β=-0.904)。
  • 最大直径与生长率相关(β=0.087)。

临床应用与阅片要点

  • 可在腹主动脉瘤层面及近端正常口径主动脉层面采集电影平衡稳态自由进动序列以测量MR应变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Management of asymptomatic abdominal aortic aneurysm (AAA) based on maximum aneurysm diameter and growth rate fails to preempt many ruptures. Assessment of aortic wall biomechanical properties may improve assessment of progression and rupture risk. This study aimed to assess the accuracy of AAA wall strain measured by cine magnetic resonance imaging (MRI) deformable image registration (MR strain) and investigate its relationship with recent AAA progression.

METHODS: The MR strain accuracy was evaluated in silico against ground truth strain in 54 synthetic MRIs generated from a finite element model simulation of an AAA patient's abdomen for different aortic pulse pressures, tissue motions, signal intensity variations, and image noise. Evaluation included bias with 95% confidence interval (CI) and correlation analysis. Association of MR strain with AAA growth rate was assessed in 25 consecutive patients with >6 months of prior surveillance, for whom cine balanced steady-state free-precession imaging was acquired at the level of the AAA as well as the proximal, normal-caliber aorta. Univariate and multivariate regressions were used to associate growth rate with clinical variables, maximum AAA diameter (D max ), and peak circumferential MR strain through the cardiac cycle. The MR strain interoperator variability was assessed using bias with 95% CI, intraclass correlation coefficient, and coefficient of variation.

RESULTS: In silico experiments revealed an MR strain bias of 0.48% ± 0.42% and a slope of correlation to ground truth strain of 0.963. In vivo, AAA MR strain (1.2% ± 0.6%) was highly reproducible (bias ± 95% CI, 0.03% ± 0.31%; intraclass correlation coefficient, 97.8%; coefficient of variation, 7.14%) and was lower than in the nonaneurysmal aorta (2.4% ± 1.7%). D max ( β = 0.087) and MR strain ( β = -1.563) were both associated with AAA growth rate. The MR strain remained an independent factor associated with growth rate ( β = -0.904) after controlling for D max .

CONCLUSIONS: Deformable image registration analysis can accurately measure the circumferential strain of the AAA wall from standard cine MRI and may offer patient-specific insight regarding AAA progression.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Dong H, Leach JR, Kao E, et al. Measurement of Abdominal Aortic Aneurysm Strain Using MR Deformable Image Registration: Accuracy and Relationship to Recent Aneurysm Progression. Invest Radiol. 2023. PMID: 37855728. doi:10.1097/RLI.0000000000001035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。