3T下自导航冠状动脉MR血管成像检测川崎病冠状动脉瘤:与传统膈肌导航冠状动脉MR血管成像比较
本研究在76例川崎病患儿中比较自导航与膈肌导航冠状动脉MR血管成像,其中33例以冠状动脉CT血管成像/有创冠状动脉造影为参考标准。自导航序列扫描时间更短(7.49±2.31分钟 vs 10.03±4.47分钟,p<0.001),图像质量与诊断准确性均与膈肌导航无显著差异。
要点
- 自导航冠状动脉MR血管成像扫描时间较膈肌导航缩短,图像质量与诊断准确性相当。
- 以冠状动脉CT血管成像/有创冠状动脉造影为参考,两种序列检测冠状动脉瘤的诊断准确性无显著差异。
- 自导航序列可无创、无辐射评估川崎病患儿冠状动脉瘤,为风险分层和治疗提供信息。
核心结论
- 3T自导航冠状动脉MR血管成像对川崎病患儿冠状动脉瘤检测具有可靠的诊断性能和应用价值,与膈肌导航相比可简化扫描流程、缩短扫描时间,并获得相当的图像质量和诊断准确性。
研究设计与样本
- 在76例川崎病患儿(男48例,年龄6.75±3.59岁)中行自导航和膈肌导航冠状动脉MR血管成像,其中33例接受冠状动脉CT血管成像/有创冠状动脉造影作为参考标准。
诊断标准与关键数值
- 自导航与膈肌导航冠状动脉MR血管成像检测冠状动脉瘤的诊断准确性在基于患者、基于血管和基于节段层面均无显著差异(所有p>0.05),以冠状动脉CT血管成像/有创冠状动脉造影为参考标准。
临床应用与阅片要点
- 自导航冠状动脉MR血管成像可在3T下无创、无辐射检测川崎病患儿冠状动脉瘤,扫描时间较膈肌导航缩短,图像质量和诊断准确性相当,可为川崎病风险分层和治疗管理提供参考。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the scan time, image quality, and diagnostic performance of self-navigated coronary MR angiography (SN-CMRA) for coronary aneurysm (CAA) detection in Kawasaki disease (KD) patients and compare it with diaphragm-navigated CMRA (DN-CMRA).
MATERIALS AND METHODS: SN-CMRA and DN-CMRA were performed on 76 pediatric patients with KD (48 males, 6.75 ± 3.59 years). Thirty-three of whom underwent coronary CT angiography (CCTA)/invasive coronary angiography (ICA). The scan time and qualitative and quantitative image quality assessment were compared between the two sequences. The diagnostic performance for CAA detection by the two approaches using CCTA/ICA as the reference standard was compared on per-patient, per-vessel, and per-segment basis.
RESULTS: The scan time of SN-CMRA was significantly shorter than that of DN-CMRA (7.49 ± 2.31 min vs. 10.03 ± 4.47 min, p < 0.001). There was no difference in overall and segmental image quality to reach the clinical diagnostic criteria between the two sequences (all p > 0.05). No significant difference in vessel length of the three main coronary arteries was found between the two approaches (all p > 0.05). Moreover, SN-CMRA showed no difference from DN-CMRA in contrast ratio of blood-myocardium (1.25 (interquartile range [IQR], 1.06 to 1.51) vs. 1.18 (IQR, 0.95 to 1.64), p = 0.706). There was no difference in the diagnostic accuracy of SN-CMRA and DN-CMRA for CAA detection on per-patient, per-vessel, or per-segment basis (all p > 0.05).
CONCLUSION: SN-CMRA at 3T showed reliable diagnostic performance and application value for CAA detection in children with KD. Compared with DN-CMRA, SN-CMRA can simplify the scanning procedure and shorten the scan time, achieving comparable image quality and diagnostic accuracy.
CLINICAL RELEVANCE STATEMENT: Coronary aneurysm in children with Kawasaki disease (KD) can be detected by self-navigated coronary MR angiography (CMRA) non-invasively and without radiation, achieving comparable image quality and diagnostic performance as diaphragm-navigated CMRA while shortening scanning time. It can provide reference for risk stratification and treatment management of KD.
KEY POINTS: • Evaluating the size of coronary aneurysm is important for risk stratification and treatment of Kawasaki disease. • Self-navigated coronary MR angiography (SN-CMRA) shortens scan time and achieves comparable image quality and diagnostic performance compared with diaphragm-navigated coronary MR angiography. • SN-CMRA can evaluate coronary aneurysm non-invasively and without radiation, providing information for risk stratification and treatment.
引用
- Zhou Z, Wei D, Azhe S, et al. Self-navigated coronary MR angiography for coronary aneurysm detection in Kawasaki disease at 3T: comparison with conventional diaphragm-navigated coronary MR angiography. Eur Radiol. 2023. PMID: 37857903. doi:10.1007/s00330-023-10350-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。