文献速递心血管CT

利用动态心肌灌注负荷CT的分形分析鉴别大血管与微血管缺血

Differentiating Macrovascular and Microvascular Ischemia Using Fractal Analysis of Dynamic Myocardial Perfusion Stress-CT.
PubMed 文献 · Invest Radiol · 2023-10-09

基于AMPLIFiED多中心试验的127例患者,评估动态心肌负荷CT灌注成像分形分析鉴别阻塞性冠状动脉疾病与冠状动脉微血管疾病的价值,并以有创冠状动脉造影加血流储备分数及CT衍生心肌血流量为参考标准。结果显示多分类AUC为0.92,在缺血患者中鉴别CAD与CMD的敏感度95%、特异度74%、AUC 0.83,在INOCA亚组AUC 0.94,在轻中度狭窄亚组AUC 0.95。

要点

  • 分形分析鉴别CAD、CMD与正常灌注的多分类AUC为0.92、κ=0.89。
  • 缺血患者中CAD对CMD敏感度95%、特异度74%、准确率89%、AUC 0.83。
  • 非阻塞冠状动脉患者中INOCA检出敏感度100%、特异度78%、AUC 0.94。

核心结论

  • 在这项多中心研究中,4D-CTP分形分析能准确鉴别CAD与CMD,包括INOCA亚组和轻中度狭窄亚组。

研究设计与样本

  • 基于AMPLIFiED多中心试验,纳入疑似或已知慢性心肌缺血且有有创冠状动脉造影指征的患者127例(女性27%),行双源CT血管成像、4D-CTP和CT延迟强化成像;参考标准为有创冠状动脉造影加血流储备分数及绝对或相对CT衍生心肌血流量。

关键影像表现/征象

  • 分形分析用于动态心肌负荷CT灌注成像,可无创鉴别阻塞性冠状动脉疾病与冠状动脉微血管疾病。

诊断标准与关键数值

  • CAD 61例(女性23%)、CMD 23例(女性30%)、正常灌注34例(女性35%),多分类AUC 0.92、多分类κ=0.89。
  • 缺血患者84例中,分形分析检出CAD 61例而非CMD 23例:敏感度95%、特异度74%、准确率89%、AUC 0.83。
  • 非阻塞冠状动脉(狭窄≤25%)患者33例中检出INOCA 15例:敏感度100%、特异度78%、准确率88%、AUC 0.94。
  • 轻中度狭窄(26%–80%)患者27例中,分形分析检出CAD 19例而非CMD:敏感度84%、特异度100%、准确率89%、AUC 0.95。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Fractal analysis of dynamic myocardial stress computed tomography perfusion imaging (4D-CTP) has shown potential to noninvasively differentiate obstructive coronary artery disease (CAD) and coronary microvascular disease (CMD). This study validates fractal analysis of 4D-CTP in a multicenter setting and assesses its diagnostic accuracy in subgroups with ischemia and nonobstructed coronary arteries (INOCA) and with mild to moderate stenosis.

MATERIALS AND METHODS: From the AMPLIFiED multicenter trial, patients with suspected or known chronic myocardial ischemia and an indication for invasive coronary angiography were included. Patients underwent dual-source CT angiography, 4D-CTP, and CT delayed-enhancement imaging. Coronary artery disease, CMD, and normal perfusion were defined by a combined reference standard comprising invasive coronary angiography with fractional flow reserve, and absolute or relative CT-derived myocardial blood flow. Nonobstructed coronary arteries were defined as ≤25% stenosis and mild to moderate stenosis as 26%-80%.

RESULTS: In 127 patients (27% female), fractal analysis accurately differentiated CAD (n = 61, 23% female), CMD (n = 23, 30% female), and normal perfusion (n = 34, 35% female) with a multiclass area under the receiver operating characteristic curve (AUC) of 0.92 and high agreement (multiclass κ = 0.89). In patients with ischemia (n = 84), fractal analysis detected CAD (n = 61) over CMD (n = 23) with sensitivity of 95%, specificity of 74%, accuracy of 89%, and AUC of 0.83. In patients with nonobstructed coronary arteries (n = 33), INOCA (n = 15) was detected with sensitivity of 100%, specificity of 78%, accuracy of 88%, and AUC of 0.94. In patients with mild to moderate stenosis (n = 27), fractal analysis detected CAD (n = 19) over CMD with sensitivity of 84%, specificity of 100%, accuracy of 89%, and AUC of 0.95.

CONCLUSIONS: In this multicenter study, fractal analysis of 4D-CTP accurately differentiated CAD and CMD including subgroups with INOCA and with mild to moderate stenosis.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Michallek F, Nakamura S, Kurita T, et al. Differentiating Macrovascular and Microvascular Ischemia Using Fractal Analysis of Dynamic Myocardial Perfusion Stress-CT. Invest Radiol. 2023. PMID: 37812495. doi:10.1097/RLI.0000000000001027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。