支气管动脉栓塞术前「三低」辐射剂量支气管动脉CT血管成像的可行性研究
研究纳入60例BMI<30 kg/m²患者,比较「三低」方案(100 kVp、100 mAs、50 ml对比剂)与常规方案(120 kVp、自动管电流调制、80 ml对比剂)行支气管动脉CTA。结果显示三低组辐射剂量降低79.7%、对比剂用量减少37.5%、主动脉CT衰减提高约13%,主观图像质量与追溯评分两组无差异,作者认为该方案可行。
要点
- BMI<30 kg/m²患者行支气管动脉CTA时,三低方案(100 kVp、100 mAs、50 ml对比剂)较常规方案辐射剂量降低79.7%。
- 三低方案对比剂用量50 ml较常规方案80 ml减少37.5%,主动脉CT衰减提高约13%。
- 三低方案图像噪声更高、SNR与CNR更低,但主观图像质量评分与追溯评分两组无差异。
核心结论
- 对BMI<30 kg/m²患者,采用「三低」剂量CTA方案(低管电压、低管电流、低对比剂用量)是可行的,辐射剂量降低79.7%、对比剂剂量减少37.5%,同时保证诊断价值。
研究设计与样本
- 可行性研究,纳入60例BMI<30 kg/m²患者,使用256层iCT系统行支气管动脉CTA,分为A组(100 kVp、100 mAs、50 ml对比剂)与B组(120 kVp、自动管电流调制、80 ml对比剂),计算主动脉CT衰减、图像噪声、SNR、CNR,并进行主观图像质量评分与追溯评分,计算有效辐射剂量。
关键影像表现/征象
- A组主动脉CT衰减较B组提高约13%(p<0.05)。
- A组图像噪声高于B组,SNR与CNR低于B组(均p<0.05)。
- A组与B组主观图像质量评分及追溯评分均无差异(均p>0.05)。
诊断标准与关键数值
- A组辐射剂量较B组降低79.7%(p<0.05)。
- A组对比剂用量50 ml较B组80 ml减少37.5%。
- A组主动脉CT衰减较B组提高约13%(p<0.05)。
- A组图像噪声高于B组、SNR与CNR低于B组(均p<0.05)。
- A组与B组主观图像质量评分及追溯评分均无差异(均p>0.05)。
临床应用与阅片要点
- 对BMI<30 kg/m²患者行支气管动脉栓塞术前CTA,可参考「三低」方案(100 kVp、100 mAs、50 ml对比剂)以降低辐射剂量与对比剂用量。
- 采用三低方案时图像噪声升高、SNR与CNR降低,但主观图像质量与血管追溯评分与常规方案无差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To explore the feasibility of a "triple-low" dose (low tube voltage, low tube current, and low contrast agent volume) bronchial artery computed tomography (CT) angiography (CTA) to replace routine dose bronchial artery CTA before bronchial artery embolisation (BAE).
MATERIALS AND METHODS: CTA was obtained from 60 patients with body mass index (BMI) < 30 kg/m2 using a 256 multi-section iCT system, and they were divided into two groups: (1) group A: 100 kVp, 100 mAs, 50 ml contrast medium (CM); (2) group B: 120 kVp, automatic tube current modulation (ACTM), 80 ml CM. CT attenuation of the thoracic aorta, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and subjective image quality scores and traceability scores assessed. The effective radiation dose was calculated.
RESULTS: The radiation dose was reduced by 79.7% in group A compared to group B (p<0.05). The CT attenuation of the thoracic aorta was increased by approximately 13% in group A compared to group B (p<0.05). Higher image noise, lower SNR, and CNR were obtained in group A compared to group B (all p<0.05). Both subjective image quality scores and traceability scores did not differ between groups A and B (both p>0.05).
CONCLUSION: It is feasible to use the "triple-low" dose CTA protocol for patients with a body mass index (BMI) < 30 kg/m2. The radiation dose was reduced by 79.7%, and the dose of contrast medium was reduced by 37.5% to ensure the diagnostic value.