文献速递胸部MRCT

基于超短回波时间MRI的影像组学模型预测肺腺癌组织病理亚型的可行性:与CT影像组学模型的比较

Feasibility of UTE-MRI-based radiomics model for prediction of histopathologic subtype of lung adenocarcinoma: in comparison with CT-based radiomics model.
PubMed 文献 · Eur Radiol · 2023-10-16

该前瞻性研究纳入71例早期肺腺癌患者的74个病灶,评估UTE-MRI影像组学模型预测微乳头和/或实性(MP/S)病理模式的可行性。UTE-MRI与CT的Rad-score诊断性能相当(AUC 0.84 vs 0.841,p=0.98),联合常规影像、UTE-MRI及CT Rad-score的混合模型AUC最高(0.879)。生存分析显示UTE-MRI和CT的Rad-score均能成功区分高、低风险组(p=0.01;p<0.01)。

要点

  • UTE-MRI Rad-score预测MP/S的AUC为0.84,与CT Rad-score的0.841相当(p=0.98)。
  • 联合常规影像、UTE-MRI及CT Rad-score的混合模型诊断性能最高(AUC=0.879)。
  • UTE-MRI和CT的Rad-score均与术后早期复发相关(p=0.01;p<0.01)。

核心结论

  • UTE-MRI影像组学模型预测MP/S阳性是可行的,与CT影像组学模型相当,且与生存分析中的早期复发相关。

研究设计与样本

  • 前瞻性研究,纳入71例患者的74个病灶,术前接受UTE-MRI和CT检查,以手术病理为参考标准。

关键影像表现/征象

  • UTE-MRI与CT测量的病灶长径存在小的系统性差异,病灶特征评估的组间一致性为中等(kappa=0.535)。
  • 24个病灶为MP/S阳性,50个为MP/S阴性。

诊断标准与关键数值

  • UTE-MRI Rad-score预测MP/S的AUC为0.84。
  • CT Rad-score预测MP/S的AUC为0.841。
  • 混合常规影像、UTE-MRI及CT Rad-score模型预测MP/S的AUC为0.879。

临床应用与阅片要点

  • UTE-MRI无辐射危害,其影像组学模型可用于预测肺腺癌MP/S病理亚型。
  • UTE-MRI Rad-score与CT Rad-score诊断性能相当,可作为无辐射的替代或补充手段。
  • Rad-score有助于区分高、低风险组,与无复发生存相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the feasibility of the UTE-MRI radiomic model in predicting the micropapillary and/or solid (MP/S) patterns of surgically resected lung adenocarcinoma.

MATERIALS AND METHODS: We prospectively enrolled 74 lesions from 71 patients who underwent UTE-MRI and CT before curative surgery for early lung adenocarcinoma. For conventional radiologic analysis, we analyzed the longest lesion diameter and lesion characteristics at both UTE-MRI and CT. Radiomic features were extracted from the volume of interest of the lesions and Rad-scores were generated using the least absolute shrinkage and selection operator with fivefold cross-validation. Six models were constructed by combining the conventional radiologic model, UTE-MRI Rad-score, and CT Rad-score. The areas under the curves (AUCs) of each model were compared using the DeLong method. Early recurrence after curative surgery was analyzed, and Kaplan-Meier survival analysis was performed.

RESULTS: Twenty-four lesions were MP/S-positive, and 50 were MP/S-negative. The longitudinal size showed a small systematic difference between UTE-MRI and CT, with fair intermodality agreement of lesion characteristic (kappa = 0.535). The Rad-scores of the UTE-MRI and CT demonstrated AUCs of 0.84 and 0.841, respectively (p = 0.98). Among the six models, mixed conventional, UTE-MRI, and CT Rad-score model showed the highest diagnostic performance (AUC = 0.879). In the survival analysis, the high- and low-risk groups were successfully divided by the Rad-score in UTE-MRI (p = 0.01) and CT (p < 0.01).

CONCLUSION: UTE-MRI radiomic model predicting MP/S positivity is feasible compared with the CT radiomic model. Also, it was associated with early recurrence in the survival analysis.

CLINICAL RELEVANCE STATEMENT: A radiomic model utilizing UTE-MRI, which does not present a radiation hazard, was able to successfully predict the histopathologic subtype of lung adenocarcinoma, and it was associated with the patient's recurrence-free survival.

KEY POINTS: • No studies have reported the ultrashort echo time (UTE)-MRI-based radiomic model for lung adenocarcinoma. • The UTE-MRI Rad-score showed comparable diagnostic performance with CT Rad-score for predicting micropapillary and/or solid histopathologic pattern. • UTE-MRI is feasible not only for conventional radiologic analysis, but also for radiomics analysis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lee S, Lee CY, Kim NY, et al. Feasibility of UTE-MRI-based radiomics model for prediction of histopathologic subtype of lung adenocarcinoma: in comparison with CT-based radiomics model. Eur Radiol. 2023. PMID: 37840100. doi:10.1007/s00330-023-10302-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。