文献速递胸部CT

基于术前CT的深度学习影像组学模型预测高风险病理性肺结节的开发与验证

Development and Validation of a Deep Learning Radiomics Model to Predict High-Risk Pathologic Pulmonary Nodules Using Preoperative Computed Tomography.
PubMed 文献 · Acad Radiol · 2023-10-05

本研究纳入469例肺腺癌患者,分训练组400例和外部验证组69例,基于术前CT提取影像组学与深度迁移学习特征构建逻辑回归模型。联合模型训练组AUC 0.872、外部验证组AUC 0.814,优于临床模型和影像组学-深度迁移学习模型,决策曲线分析显示模型在预测高风险病理性肺结节方面提供净获益。

要点

  • 联合模型训练组AUC 0.872、外部验证组AUC 0.814,优于临床模型。
  • 影像组学-深度迁移学习模型训练组AUC 0.871、外部验证组AUC 0.806。
  • 联合模型与影像组学-深度迁移学习模型比较无统计学显著差异。

核心结论

  • 影像组学-深度迁移学习特征是利用术前CT预测高风险病理性肺结节的潜在生物标志物,可用于确定合适的手术策略并指导切除范围。

研究设计与样本

  • 研究队列为469例肺腺癌患者,分为训练组400例和外部验证组69例;获取CT语义特征和临床特征,并提取影像组学和深度迁移学习特征,采用逻辑回归算法构建预测模型。

诊断标准与关键数值

  • 临床模型训练组AUC 0.774(95% CI: 0.728-0.821),外部验证组AUC 0.762(95% CI: 0.650-0.873)。
  • 影像组学模型训练组AUC 0.847(95% CI: 0.810-0.884),外部验证组AUC 0.800(95% CI: 0.693-0.907)。
  • 影像组学-深度迁移学习模型训练组AUC 0.871(95% CI: 0.838-0.905),外部验证组AUC 0.806(95% CI: 0.698-0.914)。
  • 联合模型训练组AUC 0.872,外部验证组AUC 0.814。
  • 联合模型优于临床模型和影像组学-深度迁移学习模型;联合模型与影像组学-深度迁移学习模型比较无统计学显著差异。

临床应用与阅片要点

  • 决策曲线分析表明模型在预测高风险病理性肺结节方面提供净获益。
  • 影像组学-深度迁移学习特征是利用术前CT预测高风险病理性肺结节的潜在生物标志物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To accurately identify the high-risk pathological factors of pulmonary nodules, our study constructed a model combined with clinical features, radiomics features, and deep transfer learning features to predict high-risk pathological pulmonary nodules.

MATERIALS AND METHODS: The study cohort consisted of 469 cases of lung adenocarcinoma patients, divided into a training cohort (n = 400) and an external validation cohort (n = 69). We obtained computed tomography (CT) semantic features and clinical characteristics, as well as extracted radiomics and deep transfer learning (DTL) features from the CT images. Selected features were used for constructing prediction models using the logistic regression (LR) algorithm. The performance of the models was evaluated through metrics including the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, calibration curve, and decision curve analysis.

RESULTS: The clinical model achieved an AUC of 0.774 (95% CI: 0.728-0.821) in the training cohort and 0.762 (95% confidence interval [CI]: 0.650-0.873) in the external validation cohort. The radiomics model demonstrated an AUC of 0.847 (95% CI: 0.810-0.884) in the training cohort and 0.800 (95% CI: 0.693-0.907) in the external validation cohort. The radiomics-DTL (Rad-DTL) model showed an AUC of 0.871 (95% CI: 0.838-0.905) in the training cohort and 0.806 (95% CI: 0.698-0.914) in the external validation cohort. The proposed combined model yielded AUC values of 0.872 and 0.814 in the training and external validation cohorts, respectively. The combined model demonstrated superiority over both the clinical model and the Rad-DTL model. There were no statistically significant differences observed in the comparison between the combined model incorporating clinical features and the Rad-DTL model. Decision curve analysis (DCA) indicated that the models provided a net benefit in predicting high-risk pathologic pulmonary nodules.

CONCLUSION: Rad-DTL signature is a potential biomarker for predicting high-risk pathologic pulmonary nodules using preoperative CT, determining the appropriate surgical strategy, and guiding the extent of resection.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ye G, Wu G, Li K, et al. Development and Validation of a Deep Learning Radiomics Model to Predict High-Risk Pathologic Pulmonary Nodules Using Preoperative Computed Tomography. Acad Radiol. 2023. PMID: 37802672. doi:10.1016/j.acra.2023.08.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。