重度支气管肺发育不良的胸部CT:定量评分方法的比较
该研究纳入35例重度支气管肺发育不良患儿,在矫正年龄中位数7个月时行胸部CT,比较PRAGMA-BPD与三种基于HU的评分方法(自动、半自动、手动)的观察者内和观察者间变异性、与PRAGMA-BPD评分的相关性及与临床数据的相关性。结果显示PRAGMA-BPD和手动HU法重复性最佳,手动HU法与PRAGMA-BPD评分高度相关。
要点
- PRAGMA-BPD和手动HU法在量化BPD的CT异常时观察者内和观察者间重复性最佳。
- 手动HU法与PRAGMA-BPD评分在低衰减区和高衰减区均高度相关。
- 半自动HU法观察者间变异性较差,尤其低衰减区。
核心结论
- PRAGMA-BPD和手动HU法对BPD的CT异常量化具有最佳重复性。
研究设计与样本
- 研究纳入35例重度BPD患儿,在矫正年龄中位数7个月时行胸部CT,比较PRAGMA-BPD与三种基于HU的评分方法(自动、半自动、手动),以ICC和Bland-Altman图评估观察者内和观察者间变异性,用Spearman秩相关评估评分方法与临床数据的相关性。
关键影像表现/征象
- 手动HU法和PRAGMA-BPD对高衰减区和低衰减区的观察者内和观察者间ICC范围为0.80-0.97。
- 半自动HU法的ICC值较差,低衰减区观察者间为0.22-0.71,高衰减区观察者间为-0.06-0.89。
诊断标准与关键数值
- 手动HU法与PRAGMA-BPD评分在高衰减区高度相关(ρs=0.92,p<0.001),在低衰减区也高度相关(ρs=0.79,p<0.001)。
- 自动和半自动HU法与PRAGMA-BPD评分在低衰减区相关性差(ρs<0.22),在高衰减区相关性好(ρs=0.72-0.74,p<0.001)。
临床应用与阅片要点
- PRAGMA-BPD和手动HU法可用于重度BPD患儿胸部CT的结构性肺异常量化评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Bronchopulmonary dysplasia (BPD) is the most common complication of extreme preterm birth and structural lung abnormalities are frequently found in children with BPD. To quantify lung damage in BPD, three new Hounsfield units (HU) based chest-CT scoring methods were evaluated in terms of 1) intra- and inter-observer variability, 2) correlation with the validated Perth-Rotterdam-Annotated-Grid-Morphometric-Analysis (PRAGMA)-BPD score, and 3) correlation with clinical data.
METHODS: Chest CT scans of children with severe BPD were performed at a median of 7 months corrected age. Hyper- and hypo-attenuated regions were quantified using PRAGMA-BPD and three new HU based scoring methods (automated, semi-automated, and manual). Intra- and inter-observer variability was measured using intraclass correlation coefficients (ICC) and Bland-Altman plots. The correlation between the 4 scoring methods and clinical data was assessed using Spearman rank correlation.
RESULTS: Thirty-five patients (median gestational age 26.1 weeks) were included. Intra- and inter-observer variability was excellent for hyper- and hypo-attenuation regions for the manual HU method and PRAGMA-BPD (ICCs range 0.80-0.97). ICC values for the semi-automated HU method were poorer, in particular for the inter-observer variability of hypo- (0.22-0.71) and hyper-attenuation (-0.06-0.89). The manual HU method was highly correlated with PRAGMA-BPD score for both hyper- (ρs0.92, p < 0.001) and hypo-attenuation (ρs0.79, p < 0.001), while automated and semi-automated HU methods showed poor correlation for hypo- (ρs < 0.22) and good correlation for hyper-attenuation (ρs0.72-0.74, p < 0.001). Several scores of hyperattenuation correlated with the use of inhaled bronchodilators in the first year of life; two hypoattenuation scores correlated with birth weight.
CONCLUSIONS: PRAGMA-BPD and the manual HU method have the best reproducibility for quantification of CT abnormalities in BPD.
引用
- Fontijn S, Balink SJA, Bonte M, et al. Chest computed tomography in severe bronchopulmonary dysplasia: Comparing quantitative scoring methods. Eur J Radiol. 2023. PMID: 37897957. doi:10.1016/j.ejrad.2023.111168