文献速递头颈外周血管CT

头颈部CT血管成像图像质量提升:个体化触发后延迟与固定延迟的比较

Image quality improvement in head and neck CT angiography: Individualized post-trigger delay versus fixed delay.
PubMed 文献 · Eur J Radiol · 2023-10-06

前瞻性研究将196例连续受试者随机分为个体化触发后延迟组(A组)和固定4秒触发后延迟组(B组)行头颈部CTA,两组CT及对比剂方案一致。A组个体化延迟3.5–7.9秒(平均5.6秒),短于固定延迟(p<0.05);A组主观图像质量更优(p<0.05),所有血管平均强化程度显著更高(均p<0.05)。

要点

  • 个体化触发后延迟平均5.6秒,短于固定4秒延迟(p<0.05)。
  • A组所有血管平均强化程度均显著高于B组(均p<0.05)。
  • 两名读者对A组主观图像质量评分均更优(p<0.05)。

核心结论

  • 与团注追踪技术中固定触发后延迟相比,个体化触发后延迟可实现可靠扫描时机、优化血管强化并获更优头颈部CTA图像质量。

研究设计与样本

  • 前瞻性研究(2022年4月至10月),196例连续受试者随机分为个体化触发后延迟组(A组)与固定4秒触发后延迟组(B组),两组CT及对比剂方案参数一致;一名读者评估客观图像质量,两名读者评估主观图像质量。

关键影像表现/征象

  • A组个体化触发后延迟范围3.5–7.9秒(平均5.6秒),短于固定延迟(p<0.05)。
  • A组所有血管平均强化程度显著高于B组(均p<0.05)。
  • 两名读者对A组主观图像质量评分均优于B组(p<0.05)。

临床应用与阅片要点

  • 采用团注追踪行头颈部CTA时,个体化触发后延迟(平均5.6秒)较固定4秒延迟可获得更优血管强化与主观图像质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the contrast media opacification of head and neck CT angiography (CTA) between conventional fixed trigger delay and individualized post-trigger delay (PTD).

METHODS: In this prospective study (April-October 2022), 196 consecutive participants were randomly divided into two groups to perform head and neck CTA in bolus tracking with either an individualized PTD (Group A) or a fixed 4-second PTD (Group B). All CT and contrast media protocol parameters were consistent between the two groups. One reader evaluated objective image quality, while two readers rated subjective image quality. Objective image quality was compared between groups via two-sample t-test, while the subjective ratings were compared with chi-square analysis.

RESULTS: Participants' clinical information including sex, age, weight, body weight index (BMI), and heart rate were not statistically different between two groups (all p > 0.05). Individualized PTD ranging from 3.5 to 7.9 s (average 5.6 s), which is shorter than fixed delays (p < 0.05). Both readers rated better subjective image quality for the Group A (p < 0.05). The mean vessel enhancement was significantly higher in Group A in all vessels (all p < 0.05).

CONCLUSIONS: Compared to the fixed post-trigger delay in bolus tracking technique, individualized post-trigger delay could achieve reliable scan timing, optimize vessel opacification and obtain better image quality for head and neck CT angiography.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yuan D, Li L, Zhang Y, et al. Image quality improvement in head and neck CT angiography: Individualized post-trigger delay versus fixed delay. Eur J Radiol. 2023. PMID: 37832195. doi:10.1016/j.ejrad.2023.111142

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。