联合梯度回波与自旋回波增强MRI降低深度学习脑转移瘤检测假阳性:多中心诊断队列验证
本研究开发了结合梯度回波与涡轮自旋回波增强MRI的深度学习(双增强DL)检测脑转移瘤,在62例内部和48例外部队列中与仅用梯度回波的深度学习(GRE DL)及神经放射科医生比较。双增强DL的阳性预测值高于GRE DL(89% vs 76%,p < .001),敏感度相似(92% vs 93%),且对转移瘤数量的高估与神经放射科医生无显著差异,而GRE DL显著高估。
要点
- 双增强DL的阳性预测值高于GRE DL(89% vs 76%,p < .001),敏感度相似。
- GRE DL显著高估转移瘤数量,而双增强DL与神经放射科医生无显著差异。
- 联合涡轮自旋回波成像可减少深度学习检测脑转移瘤的假阳性。
核心结论
- 双增强DL较GRE DL改善了脑转移瘤检测并减少高估,达到与神经放射科医生相似的性能。
研究设计与样本
- 深度学习检测模型使用200例脑转移瘤患者数据开发(训练集),在62例内部和48例外部队列中测试,患者均接受立体定向放射外科治疗及双增强成像和后续引导GRE成像;参考标准由另一名神经放射科医生独立绘制。
诊断标准与关键数值
- 双增强DL敏感度92%(95%CI 89-94%),阳性预测值89%(95%CI 86-92%);GRE DL敏感度93%(95%CI 90-96%),阳性预测值76%(95%CI 72-80%);双增强DL与神经放射科医生转移瘤数量相对差异无统计学显著差异(RD 0.00,95%CI 0.00-0.15 vs RD 0.00,95%CI -0.20-0.10,p = .913),GRE DL显著高估(RD 0.05,95%CI 0.00-0.58 vs RD 0.00,95%CI -0.28-0.15,p < .001)。
临床应用与阅片要点
- 使用结合涡轮自旋回波成像的深度学习脑转移瘤检测可减少假阳性检测,有助于在仅采用梯度回波成像时指导立体定向放射外科治疗。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop a deep learning (DL) for detection of brain metastasis (BM) that incorporates both gradient- and turbo spin-echo contrast-enhanced MRI (dual-enhanced DL) and evaluate it in a clinical cohort in comparison with human readers and DL using gradient-echo-based imaging only (GRE DL).
MATERIALS AND METHODS: DL detection was developed using data from 200 patients with BM (training set) and tested in 62 (internal) and 48 (external) consecutive patients who underwent stereotactic radiosurgery and diagnostic dual-enhanced imaging (dual-enhanced DL) and later guide GRE imaging (GRE DL). The detection sensitivity and positive predictive value (PPV) were compared between two DLs. Two neuroradiologists independently analyzed BM and reference standards for BM were separately drawn by another neuroradiologist. The relative differences (RDs) from the reference standard BM numbers were compared between the DLs and neuroradiologists.
RESULTS: Sensitivity was similar between GRE DL (93%, 95% confidence interval [CI]: 90-96%) and dual-enhanced DL (92% [89-94%]). The PPV of the dual-enhanced DL was higher (89% [86-92%], p < .001) than that of GRE DL (76%, [72-80%]). GRE DL significantly overestimated the number of metastases (false positives; RD: 0.05, 95% CI: 0.00-0.58) compared with neuroradiologists (RD: 0.00, 95% CI: - 0.28, 0.15, p < .001), whereas dual-enhanced DL (RD: 0.00, 95% CI: 0.00-0.15) did not show a statistically significant difference from neuroradiologists (RD: 0.00, 95% CI: - 0.20-0.10, p = .913).
CONCLUSION: The dual-enhanced DL showed improved detection of BM and reduced overestimation compared with GRE DL, achieving similar performance to neuroradiologists.
CLINICAL RELEVANCE STATEMENT: The use of deep learning-based brain metastasis detection with turbo spin-echo imaging reduces false positive detections, aiding in the guidance of stereotactic radiosurgery when gradient-echo imaging alone is employed.
KEY POINTS: •Deep learning for brain metastasis detection improved by using both gradient- and turbo spin-echo contrast-enhanced MRI (dual-enhanced deep learning). •Dual-enhanced deep learning increased true positive detections and reduced overestimation. •Dual-enhanced deep learning achieved similar performance to neuroradiologists for brain metastasis counts.
引用
- Yun S, Park JE, Kim N, et al. Reducing false positives in deep learning-based brain metastasis detection by using both gradient-echo and spin-echo contrast-enhanced MRI: validation in a multi-center diagnostic cohort. Eur Radiol. 2023. PMID: 37891415. doi:10.1007/s00330-023-10318-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。