文献速递神经介入MRDSA

颅内动脉瘤血管内治疗后的DWI检出缺血性病变:更新的系统综述与Meta分析

DWI-Detected Ischemic Lesions after Endovascular Treatment for Cerebral Aneurysms: An Updated Systematic Review and Meta-analysis.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-10-12

该系统综述与Meta分析纳入29项研究共2686例患者,评估颅内动脉瘤血管内治疗后5天内DWI检出缺血性病变的发生率。总体发生率为47.0%(95% CI,39.6%-55.8%),血流导向装置发生率最高为62.4%(95% CI,48.4%-80.5%),不同技术间差异无统计学意义,但存在显著异质性和发表偏倚风险。

要点

  • 颅内动脉瘤血管内治疗后DWI检出缺血性病变总体发生率为47.0%(95% CI,39.6%-55.8%)。
  • 血流导向装置发生率最高为62.4%(95% CI,48.4%-80.5%),球囊辅助弹簧圈栓塞最低为37.0%(95% CI,28.3%-48.4%)。
  • 不同血管内技术间缺血性病变发生率差异无统计学意义,但研究间异质性和发表偏倚风险显著。

核心结论

  • 无论采用何种血管内技术,许多颅内动脉瘤血管内治疗患者术后出现新的DWI检出缺血性病变;未来需进一步研究此类小梗死的早期和长期结局。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Web of Science、EMBASE和Scopus数据库2000年1月至2022年6月关于颅内动脉瘤血管内治疗后研究,使用Nested Knowledge AutoLit软件,纳入29项研究共2686例患者,主要结局为术后5天内DWI检出缺血性病变。

关键影像表现/征象

  • DWI检出缺血性病变总体发生率为47.0%(95% CI,39.6%-55.8%)。
  • 血流导向装置发生率最高为62.4%(95% CI,48.4%-80.5%)。
  • 复杂手术发生率为49.3%(95% CI,29.5%-82.1%)。
  • 支架辅助弹簧圈栓塞发生率为47.5%(95% CI,34.6%-65.3%)。
  • 单纯弹簧圈栓塞发生率为47.1%(95% CI,35.7%-62.3%),球囊辅助弹簧圈栓塞为37.0%(95% CI,28.3%-48.4%)。

诊断标准与关键数值

  • 主要结局为血管内手术后5天内DWI检出的缺血性病变。
  • DWI检出缺血性病变总体发生率为47.0%(95% CI,39.6%-55.8%)。
  • 不同技术间发生率差异无统计学意义,但研究间存在显著异质性和显著发表偏倚风险。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 纳入研究间存在显著异质性。
  • 纳入研究间存在显著发表偏倚风险。
  • 未来需进一步研究此类小梗死的早期和长期结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: DWI-detected ischemic lesions are potential complications of endovascular procedures that are performed to treat intracranial aneurysms. We completed a systematic review and meta-analysis to identify the occurrence of DWI-detected ischemic lesions after endovascular treatment for intracranial aneurysms.

MATERIALS AND METHODS: A systematic literature search of PubMed, the Web of Science, EMBASE, and Scopus between January 2000 and June 2022 of post-endovascular procedures for intracranial aneurysm studies was conducted using the Nested Knowledge AutoLit software. The main outcome was DWI-detected ischemic lesions within 5 days of the procedures. Information regarding associated risk factors such as the type of procedure, patient demographics, and aneurysm characteristics was also collected.

RESULTS: Twenty-nine studies with 2686 patients were included. The overall incidence of DWI ischemic lesions was 47.0% (95% CI, 39.6%-55.8%). The highest rate of lesions was seen with flow diversion at 62.4% (95% CI, 48.4%-80.5%), followed by complex procedures at 49.3% (95% CI, 29.5%-82.1%), stent-assisted coiling at 47.5% (95% CI, 34.6%-65.3%), simple coiling at 47.1% (95% CI, 35.7%-62.3%), and balloon-assisted coiling at 37.0% (95% CI, 28.3%-48.4%). The differences among different techniques were not statistically significant; however, there was significant heterogeneity and a significant risk of publication bias among included studies.

CONCLUSIONS: Many patients who undergo endovascular procedures for intracranial aneurysms present with new postprocedural DWI-detected ischemic lesions, regardless of the endovascular procedure used. Future studies and meta-analyses are needed to investigate early and long-term outcomes of such small infarcts.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Habtezghi AB, Ghozy S, Bilgin C, et al. DWI-Detected Ischemic Lesions after Endovascular Treatment for Cerebral Aneurysms: An Updated Systematic Review and Meta-analysis. AJNR Am J Neuroradiol. 2023. PMID: 37827721. doi:10.3174/ajnr.A8024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。