文献速递神经外周血管MR

对比增强MR血管成像的蒙片图像用于检测中重度症状性和无症状性颈动脉狭窄患者的颈动脉斑块内出血

Application of mask images of contrast-enhanced MR angiography to detect carotid intraplaque hemorrhage in patients with moderate to severe symptomatic and asymptomatic carotid stenosis.
PubMed 文献 · Eur J Radiol · 2023-10-06

本研究纳入36例颈动脉狭窄≥50%的患者,以MP-RAGE为参考标准,评估对比增强MR血管成像蒙片和TOF检测斑块内出血的敏感度和特异度。蒙片图像敏感度>81%、特异度>95%,TOF敏感度仅50-60%;结论认为常规采集的蒙片图像可作为MP-RAGE的替代方法显示斑块内出血,而TOF不行。

要点

  • 蒙片检测斑块内出血的敏感度>81%、特异度>95%,TOF敏感度仅50-60%。
  • 蒙片与MP-RAGE检测斑块内出血的观察者间一致性极好(κ=0.96)。
  • 蒙片图像质量(1.42±0.66)显著低于MP-RAGE(3.47±0.61)。

核心结论

  • 尽管图像质量较低,常规采集的对比增强MR血管成像蒙片图像可作为MP-RAGE的替代方法显示斑块内出血,而TOF不行。

研究设计与样本

  • 研究纳入正在进行的第二届欧洲颈动脉外科试验中36例颈动脉狭窄≥50%的患者,行颈动脉MRI检查。
  • 采用5分图像质量评分,由两名独立读者评估观察者间一致性。
  • 以MP-RAGE为参考标准,计算蒙片MRA和TOF检测斑块内出血的敏感度和特异度。

关键影像表现/征象

  • 蒙片图像质量评分为1.42±0.66,TOF为2.42±0.66,均显著低于MP-RAGE的3.47±0.61。

诊断标准与关键数值

  • 36例患者中66/72条颈动脉可评分;MP-RAGE、蒙片和TOF识别斑块内出血的观察者间一致性κ分别为0.93、0.96和0.85。
  • 以MP-RAGE为参考标准,用T1w图像勾画颈动脉外壁时,蒙片和TOF检测斑块内出血的特异度均>95%,蒙片敏感度>81%,TOF敏感度50-60%。
  • 不用T1w图像勾画外壁时,特异度仍>97%,敏感度降至62-71%。

临床应用与阅片要点

  • 常规采集的对比增强MR血管成像蒙片图像可用于显示颈动脉斑块内出血,TOF不适用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Carotid intraplaque hemorrhage (IPH) on MRI predicts stroke. Magnetization-prepared rapid acquisition gradient (MP-RAGE) is widely used to detect IPH. CE-MRA is used routinely to assess stenosis. Initial studies indicated that IPH can be identified on mask images of CE-MRA, while Time-of-Flight (TOF) images were reported to have high specificity but lower sensitivity. We investigated the diagnostic accuracy of detecting IPH on mask images of CE-MRA and TOF.

METHODS: Thirty-six patients with ≥ 50% stenosis enrolled in the ongoing 2nd European Carotid Surgery Trial underwent carotid MRI. A 5-point quality score was used. Inter-observer agreement between two independent readers was determined. The sensitivity and specificity of IPH detection on mask MRA and TOF were calculated with MP-RAGE as a reference standard.

RESULTS: Of the 36 patients included in the current analysis, 66/72 carotid arteries could be scored. The inter-observer agreements for identifying IPH on MP-RAGE, mask, and TOF were outstanding (κ: 0.93, 0.96, and 0.85). The image quality of mask (1.42 ± 0.66) and TOF (2.42 ± 0.66) was significantly lower than MP-RAGE (3.47 ± 0.61). When T1w images were used to delineate the outer carotid wall, very high specificities (>95%) of IPH detection on mask and TOF images were found, while the sensitivity was high for mask images (>81%) and poor for TOF (50-60%). Without these images, the specificity was still high (>97%), while the sensitivity reduced to 62-71%.

CONCLUSION: Despite the lower image quality, routinely acquired mask images from CE-MRA, but not TOF, can be used as an alternative to MP-RAGE images to visualize IPH.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kassem M, de Kam SS, van Velzen TJ, et al. Application of mask images of contrast-enhanced MR angiography to detect carotid intraplaque hemorrhage in patients with moderate to severe symptomatic and asymptomatic carotid stenosis. Eur J Radiol. 2023. PMID: 37837923. doi:10.1016/j.ejrad.2023.111145